First molar radicular bone near the maxillary sinus: a comparison of CBCT analysis and gross anatomic dissection for small bony measurement

被引:28
作者
Howe, Robert B. [1 ]
机构
[1] Univ Calif San Francisco, Dept Prevent & Restorat Dent Sci, San Francisco, CA 94143 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2009年 / 108卷 / 02期
关键词
BEAM COMPUTED-TOMOGRAPHY; TEMPOROMANDIBULAR-JOINT; LINEAR MEASUREMENTS; ACCURACY; FLOOR; CT;
D O I
10.1016/j.tripleo.2008.12.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study assessed agreement of cone-beam computerized tomography (CBCT) measurements against those obtained by gross dissection and physical calipers for dimensions of maxillary bone around first molar roots in cadaveric specimens. Study design. A total of 37 human maxilla pairs with 69 first molars were analyzed by CBCT with a resolution of 200 mu m and the results compared with gross dissection. Matched data sets of 414 data points (6 data points per tooth) were compared using Bland-Altman statistics. An operational definition of clinical accuracy was proposed. Results. The data sets displayed a Pearson correlation coefficient of r = 0.85. Analysis revealed a positive bias for CBCT of 0.4 mm with a standard deviation of 1.1 mm relative to gross dissection. Less bone around first molar roots was demonstrated than reported in available literature. Conclusions. High-resolution CBCT measurements were acceptable for clinical accuracy and study of the maxillary sinus. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 264-269)
引用
收藏
页码:264 / 269
页数:6
相关论文
共 22 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   1800 HUNDRED YEARS OF CONTROVERSY - PARANASAL SINUSES [J].
BLANTON, PL ;
BIGGS, NL .
AMERICAN JOURNAL OF ANATOMY, 1969, 124 (02) :135-&
[4]  
CHRISTIANSEN EL, 1986, ACTA ODONTOL SCAND, V44, P221, DOI 10.3109/00016358608997724
[5]   A COMPUTED TOMOGRAPHIC STUDY OF THE DISTANCES BETWEEN THE MAXILLARY SINUS FLOOR AND THE APICES OF THE MAXILLARY POSTERIOR TEETH [J].
EBERHARDT, JA ;
TORABINEJAD, M ;
CHRISTIANSEN, EL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 73 (03) :345-346
[6]  
GARRETSON JE, 1873, SYSTEM ORAL SURG BEI
[7]   Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography [J].
Hilgers, ML ;
Scarfe, WC ;
Scheetz, JP ;
Farman, AG .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (06) :803-811
[8]   Evaluation of the usefulness of the limited cone-beam CT (3DX) in the assessment of the thickness of the roof of the glenoid fossa of the temporomandibular joint [J].
Honda, K ;
Arai, Y ;
Kashima, M ;
Takano, Y ;
Sawada, K ;
Ejima, K ;
Iwai, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (06) :391-395
[9]   Ortho cubic super-high resolution computed tomography: A new radiographic technique with application to the temporomandibular joint [J].
Honda, K ;
Larheim, TA ;
Johannessen, S ;
Arai, Y ;
Shinoda, K ;
Westesson, PL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (02) :239-243
[10]   Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom) [J].
Lascala, C ;
Panella, J ;
Marques, MM .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) :291-294