Cervical spinal cord MTR histogram analysis in multiple sclerosis using a 3D acquisition and a B-spline active surface segmentation technique

被引:21
作者
Hickman, SJ
Hadjiprocopis, A
Coulon, O
Miller, DH
Barker, GJ
机构
[1] UCL, NMR Res Unit, Inst Neurol, London WC1N 3BG, England
[2] Ecole Super Ingenieurs Luminy, CNRS, Lab Sci Informat & Syst, Marseille, France
[3] Kings Coll London, Neuroimaging Res Grp, Inst Psychiat, London SE5 8AF, England
关键词
multiple sclerosis; MRI; spinal cord; magnetization transfer; magnetization transfer histograms;
D O I
10.1016/j.mri.2004.01.056
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The application of a three-dimensional magnetization transfer (MT) sequence and B-spline active surface segmentation method to produce MT histograms of the cervical spinal cord in a pilot study of controls and multiple sclerosis (MS) patients is presented. Subjects' cervical spinal cords were imaged with (a) a volume-acquired inversion-prepared fast spoiled gradient echo sequence and (b) a volume-acquired noninversion-prepared fast spoiled gradient echo MT sequence. The images were segmented using the B spline active surface technique and MT histograms were produced from the MT images. The method was sensitive enough to detect differences between seven MS patients and 10 controls in mean MT ratio (42.4 pu versus 44.0 pu, p = 0.03) and peak location (45.2 versus 46.8, p = 0.03). The spinal cord volumes obtained from the two sequences were associated with each other (parameter estimate 0.972, 95% confidence intervals 0.742, 1.202, p < 0.001). (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:891 / 895
页数:5
相关论文
共 10 条
  • [1] *ALD HEY HOSP, 1994, ALD HEY BOOK CHILDR
  • [2] An interleaved sequence for accurate and reproducible clinical measurement of magnetization transfer ratio
    Barker, GJ
    Tofts, PS
    Gass, A
    [J]. MAGNETIC RESONANCE IMAGING, 1996, 14 (04) : 403 - 411
  • [3] Bozzali M, 1999, AM J NEURORADIOL, V20, P1803
  • [4] Quantification of spinal cord atrophy from magnetic resonance images via a B-spline active surface model
    Coulon, O
    Hickman, SJ
    Parker, GJ
    Barker, GJ
    Miller, DH
    Arridge, SR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1176 - 1185
  • [5] A conventional and magnetization transfer MRI study of the cervical cord in patients with MS
    Filippi, M
    Bozzali, M
    Horsfield, MA
    Rocca, MA
    Sormani, MP
    Iannucci, G
    Colombo, B
    Comi, G
    [J]. NEUROLOGY, 2000, 54 (01) : 207 - 213
  • [6] Fischer J.S., 2001, Multiple sclerosis functional composite: Administration and scoring manual
  • [7] Hickman SJ, 2000, NEUROIMAG CLIN N AM, V10, P689
  • [8] HICKMAN SJ, 2002, P INT SOC MAGN RESON, V10, P942
  • [9] KURTZKE JF, 1983, NEUROLOGY, V33, P1444, DOI 10.1212/WNL.33.11.1444
  • [10] Magnetisation transfer ratio measurement in the cervical spinal cord: A preliminary study in multiple sclerosis
    Silver, NC
    Barker, GJ
    Losseff, NA
    GawneCain, ML
    MacManus, DG
    Thompson, AJ
    Miller, DH
    [J]. NEURORADIOLOGY, 1997, 39 (06) : 441 - 445