Quantitative Energy-Dispersive X-Ray Microanalysis of Chlorine in Cement Paste

被引:13
|
作者
Pacheco, Jose [1 ]
Copuroglu, Oguzhan [1 ]
机构
[1] Delft Univ Technol, Fac Civil Engn & Geosci, NL-2628 CN Delft, Zuid Holland, Netherlands
关键词
ELECTRON-PROBE MICROANALYSIS; C-S-H; REINFORCED-CONCRETE; INDUCED CORROSION; POROUS MATERIALS; MICROSTRUCTURE; INTERFACE; STEEL; RISK; SEM;
D O I
10.1061/(ASCE)MT.1943-5533.0001336
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy dispersive X-ray spectroscopy (EDS) is a microanalysis technique for material characterization that can provide accurate quantification of elemental composition while maintaining high spatial resolution. EDS microanalysis studies on cementitious materials can face several challenges essentially due to the complex chemical and mineralogical characteristics of cement hydration products. Furthermore, EDS microanalysis is widely carried out in "standardless analysis" mode, which relies on the internal standards of the microanalysis software. This can lead to highly erroneous analysis results because standardless analysis typically normalizes total to 100% without taking chemically bound water into account. In the case of quantifying chlorine content of a cement paste, such normalization is unacceptable because it can lead to overestimation. For accurate determination of elemental concentrations, X-ray spectra collected from minerals or glasses with known chemical compositions are necessary as references. This paper examines the performance of six different minerals containing a wide range of chlorine concentrations as standards for quantitative EDS microanalysis. Also, the influence of experimental conditions such as beam current, accelerating voltage, dwell time, and scanning mode on the obtained results is discussed. It was found that among the minerals investigated, scapolite [(Na,Ca)4(Al3Si9O24)Cl] stands out as the most favorable microanalysis standard for quantifying chlorine content in cement paste. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [2] Energy-Dispersive X-ray Microanalysis of a Herbal Antimicrobial: Fifatrol
    Reddy, K. Ramachandra
    Sahni, Chetan
    Prasad, N. K.
    Anuraag, N. S.
    Chandana, K. Hari
    Vinay, K.
    Sharma, Sanchit
    ASIAN JOURNAL OF PHARMACEUTICS, 2023, 17 (01) : 59 - 63
  • [3] Energy-Dispersive X-Ray Microanalysis of Poststapedotomy Reparative Granuloma
    Topsakal, Vedat
    Willems, Stefan
    Tange, Rinze A.
    OTOLOGY & NEUROTOLOGY, 2014, 35 (01) : E62 - E63
  • [4] PREDICTION OF CONTINUUM INTENSITY IN ENERGY-DISPERSIVE X-RAY MICROANALYSIS
    FIORI, CE
    MYKLEBUST, RL
    HEINRICH, KFJ
    YAKOWITZ, H
    ANALYTICAL CHEMISTRY, 1976, 48 (01) : 172 - 176
  • [5] ENERGY-DISPERSIVE X-RAY-MICROANALYSIS
    WHALLON, JH
    FLEGLER, SL
    KLOMPARENS, KL
    BIOSCIENCE, 1989, 39 (04) : 256 - 259
  • [7] IMPROVED REPRODUCIBILITY OF ENERGY-DISPERSIVE X-RAY MICROANALYSIS BY NORMALIZATION TO BACKGROUND
    WENDT, M
    SCHMIDT, A
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1978, 46 (01): : 179 - 183
  • [8] THE ACCURATE ALIGNMENT OF ENERGY-DISPERSIVE X-RAY-DETECTORS FOR QUANTITATIVE MICROANALYSIS
    NICHOLSON, WAP
    CRAVEN, AJ
    JOURNAL OF MICROSCOPY-OXFORD, 1992, 168 : 289 - 300
  • [9] INTERPRETATION OF COMPOSITIONAL PATTERNS FOUND BY QUANTITATIVE ENERGY-DISPERSIVE X-RAY-ANALYSIS FOR CEMENT PASTE CONSTITUENTS
    BONEN, D
    DIAMOND, S
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1994, 77 (07) : 1875 - 1882
  • [10] STANDARDLESS QUANTITATIVE ELECTRON-PROBE MICROANALYSIS WITH ENERGY-DISPERSIVE X-RAY SPECTROMETRY - IS IT WORTH THE RISK
    NEWBURY, DE
    SWYT, CR
    MYKLEBUST, RL
    ANALYTICAL CHEMISTRY, 1995, 67 (11) : 1866 - 1871