摘要
This paper demonstrates that the gas-filled compartments in the packing material commonly called "bubble wrap" can be repurposed in resource-limited regions as containers to store liquid samples, and to perform bioanalyses. The bubbles of bubble wrap are easily filled by injecting the samples into them using a syringe with a needle or a pipet tip, and then sealing the hole with nail hardener. The bubbles are transparent in the visible range of the spectrum, and can be used as "cuvettes" for absorbance and fluorescence measurements. The interiors of these bubbles are sterile and allow storage of samples without the need for expensive sterilization equipment. The bubbles are also permeable to gases, and can be used to culture and store micro-organisms. By incorporating carbon electrodes, these bubbles can be used as electrochemical cells. This paper demonstrates the capabilities of the bubbles by culturing E. coli, growing C. elegans, measuring glucose and hemoglobin spectrophotometrically, and measuring ferrocyanide electrochemically, all within the bubbles.
引用
收藏
页码:7478 / 7485
页数:8
相关论文
共 35 条
[1]   Evaluation of an Electricity-free, Culture-based Approach for Detecting Typhoidal Salmonella Bacteremia during Enteric Fever in a High Burden, Resource-limited Setting [J].
Andrews, Jason R. ;
Prajapati, Krishna G. ;
Eypper, Elizabeth ;
Shrestha, Poojan ;
Shakya, Mila ;
Pathak, Kamal R. ;
Joshi, Niva ;
Tiwari, Priyanka ;
Risal, Manisha ;
Koirala, Samir ;
Karkey, Abhilasha ;
Dongol, Sabina ;
Wen, Shawn ;
Smith, Amy B. ;
Maru, Duncan ;
Basnyat, Buddha ;
Baker, Stephen ;
Farrar, Jeremy ;
Ryan, Edward T. ;
Hohmann, Elizabeth ;
Arjyal, Amit .
PLOS NEGLECTED TROPICAL DISEASES, 2013, 7 (06)
[2]  
[Anonymous], QUANTI TRAY QUANTI T
[3]   Mobile Phone Based Clinical Microscopy for Global Health Applications [J].
Breslauer, David N. ;
Maamari, Robi N. ;
Switz, Neil A. ;
Lam, Wilbur A. ;
Fletcher, Daniel A. .
PLOS ONE, 2009, 4 (07)
[4]   A simple artificial urine for the growth of urinary pathogens [J].
Brooks, T ;
Keevil, CW .
LETTERS IN APPLIED MICROBIOLOGY, 1997, 24 (03) :203-206
[5]   An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids [J].
Chen, Dafeng ;
Mauk, Michael ;
Qiu, Xianbo ;
Liu, Changchun ;
Kim, Jitae ;
Ramprasad, Sudhir ;
Ongagna, Serge ;
Abrams, William R. ;
Malamud, Daniel ;
Corstjens, Paul L. A. M. ;
Bau, Haim H. .
BIOMEDICAL MICRODEVICES, 2010, 12 (04) :705-719
[6]   Quantifying Colorimetric Assays in Paper-Based Microfluidic Devices by Measuring the Transmission of Light through Paper [J].
Ellerbee, Audrey K. ;
Phillips, Scott T. ;
Siegel, Adam C. ;
Mirica, Katherine A. ;
Martinez, Andres W. ;
Striehl, Pierre ;
Jain, Nina ;
Prentiss, Mara ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (20) :8447-8452
[7]   A COLLECTION OF KINETIC DATA FOR THE DIFFUSION OF ORGANIC-COMPOUNDS IN POLYOLEFINS [J].
FLYNN, JH .
POLYMER, 1982, 23 (09) :1325-1344
[8]   A microplate assay for the determination of hemoglobin concentration [J].
Frenchik, MD ;
McFaul, SJ ;
Tsonev, LI .
CLINICA CHIMICA ACTA, 2004, 339 (1-2) :199-201
[9]   Transport phenomena through polymeric systems [J].
George, SC ;
Thomas, S .
PROGRESS IN POLYMER SCIENCE, 2001, 26 (06) :985-1017
[10]  
Hulme S. E., 2011, ANGEW CHEM INT EDIT, V50, P4774