Why Does Synthesized Data Improve Multi-sequence Classification?

被引:61
作者
van Tulder, Gijs [1 ]
de Bruijne, Marleen [1 ,2 ]
机构
[1] Erasmus MC Univ, Med Ctr, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[2] Univ Copenhagen, Dept Comp Sci, DK-1168 Copenhagen, Denmark
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT I | 2015年 / 9349卷
关键词
ATTENUATION CORRECTION;
D O I
10.1007/978-3-319-24553-9_65
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The classification and registration of incomplete multi-modal medical images, such as multi-sequence MRI with missing sequences, can sometimes be improved by replacing the missing modalities with synthetic data. This may seem counter-intuitive: synthetic data is derived from data that is already available, so it does not add new information. Why can it still improve performance? In this paper we discuss possible explanations. If the synthesis model is more flexible than the classifier, the synthesis model can provide features that the classifier could not have extracted from the original data. In addition, using synthetic information to complete incomplete samples increases the size of the training set. We present experiments with two classifiers, linear support vector machines (SVMs) and random forests, together with two synthesis methods that can replace missing data in an image classification problem: neural networks and restricted Boltzmann machines (RBMs). We used data from the BRATS 2013 brain tumor segmentation challenge, which includes multi-modal MRI scans with T1, T1 post-contrast, T2 and FLAIR sequences. The linear SVMs appear to benefit from the complex transformations offered by the synthesis models, whereas the random forests mostly benefit from having more training data. Training on the hidden representation from the RBM brought the accuracy of the linear SVMs close to that of random forests.
引用
收藏
页码:531 / 538
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 2010, P PYTHON SCI COMPUTI
[2]  
[Anonymous], 2008, ICML
[3]  
[Anonymous], TECHNICAL REPORT
[4]  
[Anonymous], EUROPEAN J NUCL MED
[5]   A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images [J].
Eilertsen, Karsten ;
Vestad, Line Nilsen Tor Arne ;
Geier, Oliver ;
Skretting, Arne .
ACTA ONCOLOGICA, 2008, 47 (07) :1294-1302
[6]   Sequence-independent segmentation of magnetic resonance images [J].
Fischl, B ;
Salat, DH ;
van der Kouwe, AJW ;
Makris, N ;
Ségonne, F ;
Quinn, BT ;
Dale, AM .
NEUROIMAGE, 2004, 23 :S69-S84
[7]  
Hinton Geoffrey., 2010, Mo- mentum, V9
[8]   MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration [J].
Hofmann, Matthias ;
Steinke, Florian ;
Scheel, Verena ;
Charpiat, Guillaume ;
Farquhar, Jason ;
Aschoff, Philip ;
Brady, Michael ;
Schoelkopf, Bernhard ;
Pichler, Bernd J. .
JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (11) :1875-1883
[9]  
Iglesias JE, 2013, LECT NOTES COMPUT SC, V8149, P631, DOI 10.1007/978-3-642-40811-3_79
[10]   CT substitutes derived from MR images reconstructed with parallel imaging [J].
Johansson, Adam ;
Garpebring, Anders ;
Asklund, Thomas ;
Nyholm, Tufve .
MEDICAL PHYSICS, 2014, 41 (08) :474-480