Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle Penetration

被引:265
作者
Grinshpun, Sergey A. [1 ]
Haruta, Hiroki [1 ,3 ]
Eninger, Robert M. [1 ]
Reponen, Tiina [1 ]
Mckay, Roy T. [1 ]
Lee, Shu-An [1 ,2 ]
机构
[1] Univ Cincinnati, Dept Environm Hlth, Ctr Hlth Related Aerosol Studies, Cincinnati, OH 45267 USA
[2] Feng Chia Univ, Dept Environm Engn & Sci, Taichung, Taiwan
[3] Koken Ltd, Tokyo, Japan
关键词
aerosol; breathing; leakage; penetration; respirator; surgical mask; CYCLIC-FLOW; EFFICIENCY; STEADY; BIAS;
D O I
10.1080/15459620903120086
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The protection level offered by filtering facepiece particulate respirators and face masks is defined by the percentage of ambient particles penetrating inside the protection device. There are two penetration pathways: (1) through the faceseal leakage, and the (2) filter medium. This study aimed at differentiating the contributions of these two pathways for particles in the size range of 0.03-1 mu m under actual breathing conditions. One N95 filtering facepiece respirator and one surgical mask commonly used in health care environments were tested on 25 subjects (matching the latest National Institute for Occupational Safety and Health fit testing panel) as the subjects performed conventional fit test exercises. The respirator and the mask were also tested with breathing manikins that precisely mimicked the prerecorded breathing patterns of the tested subjects. The penetration data obtained in the human subject and manikin-based tests were compared for different particle sizes and breathing patterns. Overall, 5250 particle size and exercise-specific penetration values were determined. For each value, the faceseal leakage-to-filter ratio was calculated to quantify the relative contributions of the two penetration pathways. The number of particles penetrating through the faceseal leakage of the tested respirator/mask far exceeded the number of those penetrating through the filter medium. For the N95 respirator, the excess was (on average) by an order of magnitude and significantly increased with an increase in particle size (p < 0.001): similar to 7-fold greater for 0.04 mu m, similar to 10-fold for 0.1 mu m, and similar to 20-fold for 1 mu m. For the surgical mask, the faceseal leakage-to-filter ratio ranged from 4.8 to 5.8 and was not significantly affected by the particle size for the tested submicrometer fraction. Facial/body movement had a pronounced effect on the relative contribution of the two penetration pathways. Breathing intensity and facial dimensions showed some (although limited) influence. Because most of the penetrated particles entered through the faceseal, the priority in respirator/mask development should be shifted from improving the efficiency of the filter medium to establishing a better fit that would eliminate or minimize faceseal leakage.
引用
收藏
页码:593 / 603
页数:11
相关论文
共 20 条
  • [1] Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles
    Balazy, A
    Toivola, M
    Reponen, T
    Podgo,rski, A
    Zimmer, A
    Grinshpun, SA
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2006, 50 (03) : 259 - 269
  • [2] FUNCTION OF RODLETS ON SURFACE OF FUNGAL SPORES
    BEEVER, RE
    DEMPSEY, GP
    [J]. NATURE, 1978, 272 (5654) : 608 - 610
  • [3] BROSSEAU LM, 1990, AM IND HYG ASSOC J, V51, P420
  • [4] CHEN CC, 1992, AM IND HYG ASSOC J, V53, P533, DOI 10.1202/0002-8894(1992)053<0533:COFSLI>2.0.CO
  • [5] 2
  • [6] CHEN CC, 1990, AM IND HYG ASSOC J, V51, P632, DOI 10.1202/0002-8894(1990)051<0632:FALPCO>2.0.CO
  • [7] 2
  • [8] Crutchfield C D, 1999, Appl Occup Environ Hyg, V14, P827
  • [9] Eshbaugh JP, 2009, J OCCUP ENVIRON HYG, V6, P52, DOI [10.1080/15459620802558196, 10.1080/1545962080255X196]
  • [10] Haruta H., 2008, J Int Soc Resp Prot, V25, P75