The use of ion exchange in ammonia removal under constant and variable loads

被引:56
作者
BelerBaykal, B [1 ]
Oldenburg, M [1 ]
Sekoulov, I [1 ]
机构
[1] TECH UNIV HAMBURG,ARBEITSBEREICH GEWASSERREINIGUNGSTECH,D-21071 HAMBURG,GERMANY
关键词
ammonia removal; ion exchange; clinoptilolite; filters with biological activity; peak loads;
D O I
10.1080/09593331708616438
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The potential of ammonia removal through ion exchange with clinoptilolite was investigated under constant and variable loads. Clinoptilolite, by itself and in combination with a filter With biological activity was studied. Special attention was given to peak loads of ammonia. It has been demonstrated that ion exchange is a very promising tool for this purpose both for new plants to be designed and as upgrades in existing facilities.
引用
收藏
页码:717 / 726
页数:10
相关论文
共 10 条
  • [1] BAYKAL BB, 1994, WATER RES, V28, P2039
  • [2] CZAN E, 1988, NUC CHEM WASTE MANAG, V8, P107
  • [3] *EPA, 1971, 17080 EPA
  • [4] GRADEV G, 1973, RADIOCHIM ACTA, V19, P66
  • [5] GRADEV G, 1993, 4 INT C OCC PROP UT
  • [6] JORGENSEN SE, 1976, WATER RES, V10, P213, DOI 10.1016/0043-1354(76)90130-5
  • [7] KOON JH, 1975, J WATER POLLUT CON F, V47, P448
  • [8] Sekoulov I., 1993, 2 INT SPEC C UPGR WA
  • [9] SEKOULOV I, 1993, ROYAL FLEMISH SOC EN, V2, P109
  • [10] Weber W.J., 1972, Physiochemical Processes for Water Quality Control, V1st