Safety and efficiency of the fifth generation Woven EndoBridge device: technical note

被引:38
作者
Mihalea, Cristian [1 ,2 ]
Caroff, Jildaz [1 ]
Pagiola, Igor [1 ,3 ]
Ikka, Leon [1 ]
Hashemi, Gelareh Bani [1 ]
Naderi, Soheil [1 ]
Chalumeau, Vanessa [1 ]
Ples, Horia [2 ]
Popa, Bogdan Valeriu [4 ]
Yasuda, Thomas [1 ]
de la Torre, Joaquin Jose Marenco [1 ]
Iacobucci, Marta [1 ]
Ozanne, Augustin [1 ]
Gallas, Sophie [1 ]
Rouchaud, Aymeric [5 ]
Pescariu, Sorin [6 ]
Moret, Jacques [1 ]
Spelle, Laurent [1 ]
机构
[1] Paris Sud Univ, APHP, Hop Bicetre, Dept Intervent Neuroradiol,Neuro BrainVasc Ctr, Le Kremlin Bicetre, France
[2] Univ Med & Farm Timisoara, Dept Neurosurg, Timisoara, Romania
[3] Univ Fed Sao Paulo, Dept Intervent Neuroradiol, Sao Paulo, Brazil
[4] Carol Davila Univ Med & Pharm, Floresca Clin Emergency Hosp, Dept Radiol & Med Imaging, Bucharest, Romania
[5] Mayo Clin, Dept Radiol, Rochester, MN USA
[6] Victor Babes Univ Med & Pharm, Dept Cardiol, Timisoara, Romania
关键词
RUPTURED INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; WEB DEVICE; EFFICACY; SERIES;
D O I
10.1136/neurintsurg-2018-014343
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Backround The treatment of wide neck bifurcation aneurysms remains challenging despite the introduction of new techniques (Y stenting, waffle cone technique, or flow diverter stents). The Woven EndoBridge (WEB) device is an innovative solution for this type of cerebral aneurysm. A new WEB 17 is now available and has been designed to offer smaller sized devices to optimize navigability and delivery. Methods Between February 2017 and April 2018 all patients treated with the WEB 17 device in our center were retrospectively reviewed. 25 patients with 28 non-ruptured aneurysms were identified and analyzed. Three patients with two aneurysms both treated with the WEB device were identified. Results The device was successfully deployed in all cases. Procedure related morbidity was 4% and mortality was 0%. In one case, a delayed postprocedural thromboembolic event occurred owing to device protrusion. Technical success, complications, angiographic outcomes, procedural data, and follow-ups are reported. The modified Rankin Scale score at discharge was 0 for 24 patients (96%). At the 3, 6, or 9 month follow-up, angiograms were taken of 21 of the 25 patients (84%) (24 of 28 aneurysms had been controlled); 3 patients (3 aneurysms) did not receive angiographic follow-up at the time of submission of this work. Complete occlusion was achieved in 22 of 24 aneurysms (91.66%), and 2 of 24 aneurysm (8.33%) showed a neck remnant. Conclusions The WEB 17 is safe and technically feasible, according to this retrospective single center analysis. For very small bifurcation aneurysms, the WEB 17 seems to have lower complication rates than stent assisted techniques. However, further studies are needed to evaluate the complication rate and long term efficiency.
引用
收藏
页码:511 / 515
页数:5
相关论文
共 15 条
  • [1] Efficacy and Safety of the Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-Analysis
    Asnafi, S.
    Rouchaud, A.
    Pierot, L.
    Brinjikji, W.
    Murad, M. H.
    Kallmes, D. F.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2287 - 2292
  • [2] Role of C-Arm VasoCT in the Use of Endovascular WEB Flow Disruption in Intracranial Aneurysm Treatment
    Caroff, J.
    Mihalea, C.
    Neki, H.
    Ruijters, D.
    Ikka, L.
    Benachour, N.
    Moret, J.
    Spelle, L.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1353 - 1357
  • [3] Results of Embolization Used as the First Treatment Choice in a Consecutive Nonselected Population of Ruptured Aneurysms: Clinical Results of the Clarity GDC Study
    Cognard, Christophe
    Pierot, Laurent
    Anxionnat, Rene
    Ricolfi, Frederic
    [J]. NEUROSURGERY, 2011, 69 (04) : 837 - 841
  • [4] WEB Device for Endovascular Treatment of Wide-Neck Bifurcation Aneurysms
    Lubicz, B.
    Mine, B.
    Collignon, L.
    Brisbois, D.
    Duckwiler, G.
    Strother, C.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (06) : 1209 - 1214
  • [5] Systematic Review of Woven EndoBridge for Wide-Necked Bifurcation Aneurysms: Complications, Adequate Occlusion Rate, Morbidity, and Mortality
    Lv, Xianli
    Zhang, Yupeng
    Jiang, Weijian
    [J]. WORLD NEUROSURGERY, 2018, 110 : 20 - 25
  • [6] An update to the Raymond-Roy Occlusion Classification of intracranial aneurysms treated with coil embolization
    Mascitelli, Justin R.
    Moyle, Henry
    Oermann, Eric K.
    Polykarpou, Maritsa F.
    Patel, Aanand A.
    Doshi, Amish H.
    Gologorsky, Yakov
    Bederson, Joshua B.
    Patel, Aman B.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (07) : 496 - 502
  • [7] International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion
    Molyneux, AJ
    Kerr, RSC
    Yu, LM
    Clarke, M
    Sneade, M
    Yarnold, JA
    Sandercock, P
    [J]. LANCET, 2005, 366 (9488) : 809 - 817
  • [8] Moret J, 1997, J NEURORADIOLOGY, V24, P30
  • [9] Safety and Efficacy of Balloon Remodeling Technique during Endovascular Treatment of Intracranial Aneurysms: Critical Review of the Literature
    Pierot, L.
    Cognard, C.
    Spelle, L.
    Moret, J.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) : 12 - 15
  • [10] Pierot L, 2013, NEUROSURGERY, V34, P1209