Comparison of the Biomechanical Changes After Percutaneous Full-Endoscopic Anterior Cervical Discectomy versus Posterior Cervical Foraminotomy at C5-C6: A Finite Element-Based Study

被引:20
作者
Yuchi, Chen-Xi [1 ,2 ]
Sun, Guiming [3 ]
Chen, Chao [3 ]
Liu, Gang [3 ]
Zhao, Dong [3 ]
Yang, Haiyun [3 ]
Xu, Baoshan [3 ]
Deng, Shucai [3 ]
Ma, Xinlong [3 ]
Du, Cheng-Fei [1 ,2 ]
Yang, Qiang [3 ]
机构
[1] Tianjin Univ Technol, Sch Mech Engn, Tianjin Key Lab Adv Machatron Syst Design & Intel, Tianjin, Peoples R China
[2] Tianjin Univ Technol, Natl Demonstrat Ctr Expt Alechameal & Elect Engn, Tianjin, Peoples R China
[3] Tianjin Hosp, Dept Spine Surg, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanics; Finite element study; Percutaneous full-endoscopic anterior cervical discectomy; Posterior cervical foraminotomy; STRUCTURAL-PROPERTIES; DISC REPLACEMENT; SPINE; SEGMENT; STABILITY; MOTION; VALIDATION; PREDICTION; COMPONENTS; STRENGTHS;
D O I
10.1016/j.wneu.2019.05.025
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Percutaneous full-endoscopic anterior cervical discectomy (PEACD) and posterior cervical foraminotomy (PCF) have been reported as effective treatments for the cervical spondylosis radiculopathy (CSR), but the biomechanical effects on the discs and facet joints of PEACD and PCF remain largely unclear. The purpose of this paper is to investigate and compare the biomechanical changes on cervical spine after PECAD and PCF procedures, thus providing evidences for surgeons to select a more appropriate approach. METHODS: An intact cervical C5-C6 digital model was constructed and then modified to obtain the PCF and PEACD models using finite element method. All the models were subjected to a 73.6N preload accompanied by a 1.8 Nm moment during flexion, extension, axial rotation, lateral bending. The range of motion (ROM), intervertebral disc pressure (IDP), facet joint contact area, and contact pressure were calculated under different loading conditions. RESULTS: The ROM of the PCF model changed slightly (0.28%), whereas that of the PEACD model increased significantly (20.49%) compared with intact model. The trend of IDP changes in these 2 surgical models were similar to ROM in the corresponding motion state. The contact pressure on the facet joint of the PEACD model increased by 20.53%, 33.38%, and 17.46% during extension, lateral bending, and axial bending, respectively, compared with the intact model, and the PCF increased by 33.53% and 16.16% during extension and lateral bending, respectively, whereas it decreased 0.97% in axial rotation. The facet joint contact area of the PCF model increased by 85.71%, 1.54%, and 2.17% during extension, lateral bending, and axial rotation, respectively, and the area of the PEACD model increased by 157.14% and 36.96% during extension and axial rotation, whereas it decreased by 13.85% during lateral bending. CONCLUSIONS: This is the first biomechanical finite element study comparing PEACD with PCF for the treatment of CSR. Our results showed that PEACD led to hypermobility with high IDP within the cervical segment undergone surgery, whereas the ROM and IDP changed slightly after PCF. The variations of the contact stress indicated that both procedures changed the transmission path of the force on the facet joint and may accelerate the degeneration of the facet joint. PCF may be a better choice for the treatment of CSR compared with PEACD.
引用
收藏
页码:E905 / E911
页数:7
相关论文
共 32 条
  • [11] Kerry G, 2015, BRIT J NEUROSURG, V31, P39
  • [12] Kimpara Hideyuki, 2006, Stapp Car Crash J, V50, P509
  • [13] Kumaresan S, 1997, J SPINAL DISORD, V10, P40
  • [14] Finite element modeling approaches of human cervical spine facet joint capsule
    Kumaresan, S
    Yoganandan, N
    Pintar, FA
    [J]. JOURNAL OF BIOMECHANICS, 1998, 31 (04) : 371 - 376
  • [15] Standing balance and sagittal plane spinal deformity - Analysis of spinopelvic and gravity line parameters
    Lafage, Virginie
    Schwab, Frank
    Skalli, Wafa
    Hawkinson, Nicola
    Gagey, Pierre-Marie
    Ondra, Stephen
    Farcy, Jean-Pierre
    [J]. SPINE, 2008, 33 (14) : 1572 - 1578
  • [16] Comparison of Cervical Spine Biomechanics After Fixed- and Mobile-Core Artificial Disc Replacement: A Finite Element Analysis
    Lee, Sang-Hun
    Im, Yang-Jin
    Kim, Ki-Tack
    Kim, Yoon-Hyuk
    Park, Won-Man
    Kim, Kyungsoo
    [J]. SPINE, 2011, 36 (09) : 700 - 708
  • [17] Preservation of Motion at the Surgical Level after Minimally Invasive Posterior Cervical Foraminotomy
    Lee, Young-Seok
    Kim, Young-Baeg
    Park, Seung-Won
    Kang, Dong-Ho
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2017, 60 (04) : 433 - 440
  • [18] Levin KH, 1987, DIG WORLD LATEST MED, V7, P486
  • [19] Biomechanical effects of cervical arthroplasty with U-shaped disc implant on segmental range of motion and loading of surrounding soft tissue
    Mo, Zhong Jun
    Bin Zhao, Yan
    Wang, Li Zhen
    Sun, Yu
    Zhang, Ming
    Fan, Yu Bo
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (03) : 613 - 621
  • [20] Biomechanical consideration of prosthesis selection in hybrid surgery for bi-level cervical disc degenerative diseases
    Mo, Zhongjun
    Li, Qi
    Jia, Zhiwei
    Yang, Jiemeng
    Wong, Duo Wai-Chi
    Fan, Yubo
    [J]. EUROPEAN SPINE JOURNAL, 2017, 26 (04) : 1181 - 1190