A Feasibility Study on Autonomous Online Condition Monitoring of High-Voltage Overhead Power Lines

被引:76
作者
Zangl, Hubert [1 ]
Bretterklieber, Thomas [1 ]
Brasseur, Georg [1 ]
机构
[1] Graz Univ Technol, Inst Elect Measurement & Measurement Signal Proc, A-8010 Graz, Austria
关键词
Data transmission; energy harvesting; online condition monitoring; overhead power lines;
D O I
10.1109/TIM.2009.2012943
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For electric power transmission, high-voltage overhead power lines play an important role, as the costs for power transmission are comparatively low. However, the sag of the conductors (e.g., due to temperature variations, aging, or icing of conductors as a result of extreme weather conditions) may increase safety margins and limit the operability of these power lines. Furthermore, heavy loads due to icing or vibrations excited by wind streams increase the risk of line breakage. With online condition monitoring of power lines, critical states can be detected early, and appropriate countermeasures can be applied. In this paper, we investigate possibilities for monitoring devices that are directly mounted onto a conductor. The feasibility of powering the device from the electric field, protection of electronic circuitry from strong electric fields, and data transmission by means of a wireless link is demonstrated, as well as its operability during the presence of strong magnetic fields due to high currents and transient signals due to partial and spark discharge events.
引用
收藏
页码:1789 / 1796
页数:8
相关论文
共 12 条
[1]   Overhead-ground-wire power supply regulation by IVACE [J].
Bolduc, L ;
Brissette, Y ;
Beaudin, D ;
Pagé, D ;
Bérubé, A ;
Savard, P .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :393-399
[2]  
*EN, 2005, 10107 EN
[3]  
*EN, 2006, 607401 EN
[4]   Measurement of frequency response of overhead power lines to wind [J].
Ishino, R ;
Ishikawa, T .
IEEE POWER ENGINEERING SOCIETY - 1999 WINTER MEETING, VOLS 1 AND 2, 1999, :1327-1332
[5]   Lightning induced voltages on multiconductor power distribution line [J].
Kannu, PD ;
Thomas, MJ .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (06) :855-863
[6]  
KANNU PD, 1999, P 11 INT S HIGH VOLT, P315
[7]  
Lacroix M., 2008, Proc.CIFRE, pB2
[8]   De-icing EHV overhead transmission lines using electromagnetic forces generated by moderate short-circuit currents [J].
Landry, M ;
Beauchemin, R ;
Venne, A .
2000 IEEE ESMO - 2000 IEEE 9TH INTERNATIONAL CONFERENCE ON TRANSMISSION & DISTRIBUTION CONSTRUCTION, OPERATION & LIVE-LINE MAINTENANCE PROCEEDINGS, 2000, :94-100
[9]   Design and construction of a pollution monitor for power line insulators [J].
RamirezNino, J ;
Pacheco, MJO ;
Rodriguez, J ;
Castano, VM .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (06) :876-881
[10]  
SADANANDAN ND, 1990, P SOUT NEW ORL LA AP, P675