Quantification of recombinant human erythropoietin by amino acid analysis using isotope dilution liquid chromatography-tandem mass spectrometry

被引:19
|
作者
Yim, Jung-Hyuk [1 ,2 ]
Yoon, Ina [3 ]
Yang, Hyo-Jin [1 ,4 ]
Kim, Sook-Kyung [1 ]
Park, Sang-Ryoul [1 ]
Lee, Yong-Moon [2 ]
Jeong, Ji-Seon [1 ]
机构
[1] Korea Res Inst Stand & Sci, Dept Metrol Qual Life, Ctr Bioanal, Taejon 305340, South Korea
[2] Chungbuk Natl Univ, Dept Pharm, Grad Sch, Chungbuk 361763, South Korea
[3] Univ Penn, Dept Chem, Philadelphia, PA 19104 USA
[4] Univ Sci & Technol, Dept Bioanalyt Sci, Taejon, South Korea
关键词
Protein quantification; Amino acid analysis; Erythropoietin; Isotope dilution mass spectrometry (ID-MS); UPLC-MS/MS; HUMAN GROWTH-HORMONE; FLUORESCENCE DETECTION; PROTEIN; QUANTITATION; HYDROLYSIS;
D O I
10.1007/s00216-014-7838-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein, we describe an accurate method for protein quantification based on conventional acid hydrolysis and an isotope dilution-ultra performance liquid chromatography-tandem mass spectrometry method. The analyte protein, recombinant human erythropoietin (rhEPO), was effectively hydrolyzed by incubation with 8 mol/L hydrochloric acid at 130 A degrees C for 48 h, in which at least 1 mu mol/kg of rhEPO was treated to avoid possible degradation of released amino acids during hydrolysis. Prior to hydrolysis, sample solution was subjected to ultrafiltration to eliminate potential interfering substances. In a reversed-phase column, the analytes (phenylalanine, proline, and valine) were separated within 3 min using gradient elution comprising 20 % (v/v) acetonitrile and 10 mmol/L ammonium acetate, both containing 0.3 % (v/v) trifluoroacetic acid. The optimized hydrolysis and analytical conditions in our study were strictly validated in terms of accuracy and precision, and were suitable for the accurate quantification of rhEPO. Certified rhEPO was analyzed using a conventional biochemical assay kit as an additional working calibrant for the quantification of EPO and improved the accuracy. The optimized protocol is suitable for the accurate quantification of rhEPO and satisfactorily serves as a reference analytical procedure for the certification of rhEPO and similar proteins.
引用
收藏
页码:4401 / 4409
页数:9
相关论文
共 50 条
  • [1] Quantification of recombinant human erythropoietin by amino acid analysis using isotope dilution liquid chromatography–tandem mass spectrometry
    Jung-Hyuk Yim
    Ina Yoon
    Hyo-Jin Yang
    Sook-Kyung Kim
    Sang-Ryoul Park
    Yong-Moon Lee
    Ji-Seon Jeong
    Analytical and Bioanalytical Chemistry, 2014, 406 : 4401 - 4409
  • [2] Quantification of melatonin in human saliva by liquid chromatography-tandem mass spectrometry using stable isotope dilution
    Eriksson, K
    Östin, A
    Levin, JO
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01): : 115 - 123
  • [3] Quantification of human growth hormone by amino acid composition analysis using isotope dilution liquid-chromatography tandem mass spectrometry
    Jeong, Ji-Seon
    Lim, Hyuk-Min
    Kim, Sook-Kyung
    Ku, Hyung-Keun
    Oh, Kyung-Hwa
    Park, Sang-Ryoul
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (38) : 6596 - 6602
  • [4] Pantothenic acid quantification by a stable isotope dilution assay based on liquid chromatography-tandem mass spectrometry
    Rychlik, M
    ANALYST, 2003, 128 (07) : 832 - 837
  • [5] Quantification of estrogens in infant formulas by isotope dilution liquid chromatography-tandem mass spectrometry
    Liu, Shuan
    Li, Xiaomin
    Zhao, Yingchen
    Yin, Xiong
    Zhang, Qinghe
    Li, Xiuqin
    Tang, Guangshi
    Li, Hongmei
    ANALYTICAL METHODS, 2018, 10 (32) : 3968 - 3975
  • [6] Quantification of mycophenolic acid in plasma by isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method
    Lin, Jing
    Shen, Min
    Yu, Ting
    Wang, Huimin
    Pan, Jingjue
    Huang, Gaipeng
    Li, Quanle
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (08) : 1607 - 1617
  • [7] Quantification of organic contaminants in urban stormwater by isotope dilution and liquid chromatography-tandem mass spectrometry
    Fan Hou
    Zhenyu Tian
    Katherine T. Peter
    Christopher Wu
    Alex D. Gipe
    Haoqi Zhao
    Ernesto A. Alegria
    Fengmao Liu
    Edward P. Kolodziej
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7791 - 7806
  • [8] Identification and Quantification of Dityrosine in Grain Proteins by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Nguyen, D. D.
    Johnson, S. K.
    Clarke, M. W.
    FOOD ANALYTICAL METHODS, 2017, 10 (10) : 3321 - 3328
  • [9] Identification and Quantification of Dityrosine in Grain Proteins by Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
    D. D. Nguyen
    S. K. Johnson
    M. W. Clarke
    Food Analytical Methods, 2017, 10 : 3321 - 3328
  • [10] Quantification of organic contaminants in urban stormwater by isotope dilution and liquid chromatography-tandem mass spectrometry
    Hou, Fan
    Tian, Zhenyu
    Peter, Katherine T.
    Wu, Christopher
    Gipe, Alex D.
    Zhao, Haoqi
    Alegria, Ernesto A.
    Liu, Fengmao
    Kolodziej, Edward P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (29) : 7791 - 7806