Backprojection-filtration reconstruction for helical cone-beam CT with curved detectors

被引:0
|
作者
Zuo, Nianming [1 ]
Xia, Dan [1 ]
Sidky, Emil Y. [1 ]
Yu, Lifeng [1 ]
Zou, Yu [1 ]
Pan, Xiaochuan [1 ]
Tang, Tianzi [1 ]
机构
[1] Chinese Acad Sci, Inst Automat, Beijing 100864, Peoples R China
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
computed tomography (CT); image reconstruction; backprojection-filtration; curved detector;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Helical CT scanners with multi-row detectors have gained wide popularity in clinics. With increasing interest in extending the number of detector rows, the cone angle must be accounted for in image reconstruction algorithms. As the cone angle increases, artifacts in reconstructed images caused by approximate algorithms, such as the widely used FDK-based algorithms [1], become more of a factor that degrades the image quality. Recently, a novel reconstruction algorithm for helical cone-beam CT (CB-CT) has been proposed [2] [3], which is referred to as the backprojection-filtration algorithm. This algorithm requires theoretically minimum data to reconstruct a volume image. The original BPF algorithm was presented by assuming a flat-panel detector. However, most current multi-row detectors employed in clinic CT scanners are curved detectors. In this work, we modify the backprojection-filtration (BPF) algorithm to allow for reconstruction from data collected with a curved detector. We perform simulation studies using the Shepp-Logan phantom to evaluate the modified BPF algorithm.
引用
收藏
页码:2306 / 2309
页数:4
相关论文
共 50 条
  • [1] A general exact reconstruction for cone-beam CT via backprojection-filtration
    Ye, YB
    Zhao, SY
    Yu, HY
    Wang, G
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (09) : 1190 - 1198
  • [2] A Rebinning-type Backprojection-Filtration Algorithm for Image Reconstruction in Helical Cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil
    Pan, Xiaochuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2869 - 2872
  • [3] Parallel Backprojection-Filtration Algorithm for 3D Helical Cone-Beam CT
    Liu, Baodong
    Zeng, Li
    Zou, Xiaobing
    2010 6TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS NETWORKING AND MOBILE COMPUTING (WICOM), 2010,
  • [4] A Filtered Backprojection Algorithm for Triple-Source Helical Cone-Beam CT
    Zhao, Jun
    Jin, Yannan
    Lu, Yang
    Wang, Ge
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) : 384 - 393
  • [5] A cone-beam tomography system with a reduced size planar detector: A backprojection-filtration reconstruction algorithm as well as numerical and practical experiments
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    Kang, Kejun
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (09) : 1041 - 1047
  • [6] Exact image reconstruction for selected ROI in helical cone-beam CT
    Pan, XC
    Zou, Y
    Xia, D
    Sidky, E
    Jiang, TZ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3773 - 3776
  • [7] Derivative-Hilbert-Backprojection based image reconstruction from truncated projections in helical cone-beam CT
    张峰
    闫镔
    李磊
    席晓琦
    江桦
    魏星
    张翔
    崔进鲜
    Nuclear Science and Techniques, 2015, 26 (02) : 49 - 57
  • [8] Derivative-Hilbert-Backprojection based image reconstruction from truncated projections in helical cone-beam CT
    Zhang Feng
    Yan Bin
    Li Lei
    Xi Xiao-Qi
    Jiang Hua
    Wei Xing
    Zhang Xiang
    Cui Jin-Xian
    NUCLEAR SCIENCE AND TECHNIQUES, 2015, 26 (02)
  • [9] A weighted rebinned backprojection-filtration algorithm from partially beam-blocked data for a single-scan cone-beam CT with hybrid type scatter correction
    Min, Jonghwan
    Pua, Rizza
    Kim, Changhwan
    Park, Miran
    Lee, Jongha
    Ye, Sung-Joon
    Cho, Seungryong
    MEDICAL PHYSICS, 2019, 46 (03) : 1182 - 1197
  • [10] Chord-based image reconstruction in cone-beam CT with a curved detector
    Zuo, Nianming
    Xia, Dan
    Zou, Yu
    Jiang, Tianzi
    Pan, Xiao-Chuan
    MEDICAL PHYSICS, 2006, 33 (10) : 3743 - 3757