Deep learning-based image restoration algorithm for coronary CT angiography

被引:209
作者
Tatsugami, Fuminari [1 ]
Higaki, Toru [1 ]
Nakamura, Yuko [1 ]
Yu, Zhou [2 ]
Zhou, Jian [2 ]
Lu, Yujie [2 ]
Fujioka, Chikako [3 ]
Kitagawa, Toshiro [4 ]
Kihara, Yasuki [4 ]
Iida, Makoto [1 ]
Awai, Kazuo [1 ]
机构
[1] Hiroshima Univ, Dept Diagnost Radiol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[2] Canon Med Res USA Inc, 706 N Deerpath Dr, Vernon Hills, IL 60061 USA
[3] Hiroshima Univ, Dept Radiol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[4] Hiroshima Univ, Dept Cardiovasc Med, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
关键词
Computed tomography angiography; Cardiac imaging techniques; Artificial intelligence; Image enhancement; LOW-DOSE CT; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; 64-MDCT;
D O I
10.1007/s00330-019-06183-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The purpose of this study was to compare the image quality of coronary computed tomography angiography (CTA) subjected to deep learning-based image restoration (DLR) method with images subjected to hybrid iterative reconstruction (IR). Methods We enrolled 30 patients (22 men, 8 women) who underwent coronary CTA on a 320-slice CT scanner. The images were reconstructed with hybrid IR and with DLR. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured on all images and the contrast-to-noise ratio (CNR) in the proximal coronary arteries was calculated. We also generated CT attenuation profiles across the proximal coronary arteries and measured the width of the edge rise distance (ERD) and the edge rise slope (ERS). Two observers visually evaluated the overall image quality using a 4-point scale (1 = poor, 4 = excellent). Results On DLR images, the mean image noise was lower than that on hybrid IR images (18.5 +/- 2.8 HU vs. 23.0 +/- 4.6 HU, p < 0.01) and the CNR was significantly higher (p < 0.01). The mean ERD was significantly shorter on DLR than on hybrid IR images, whereas the mean ERS was steeper on DLR than on hybrid IR images. The mean image quality score for hybrid IR and DLR images was 2.96 and 3.58, respectively (p < 0.01). Conclusions DLR reduces the image noise and improves the image quality at coronary CTA.
引用
收藏
页码:5322 / 5329
页数:8
相关论文
共 22 条
[1]   Lung Pattern Classification for Interstitial Lung Diseases Using a Deep Convolutional Neural Network [J].
Anthimopoulos, Marios ;
Christodoulidis, Stergios ;
Ebner, Lukas ;
Christe, Andreas ;
Mougiakakou, Stavroula .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (05) :1207-1216
[2]   A survey of MRI-based medical image analysis for brain tumor studies [J].
Bauer, Stefan ;
Wiest, Roland ;
Nolte, Lutz-P ;
Reyes, Mauricio .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13) :R97-R129
[3]   Deep Learning in Mammography Diagnostic Accuracy of a Multipurpose Image Analysis Software in the Detection of Breast Cancer [J].
Becker, Anton S. ;
Marcon, Magda ;
Ghafoor, Soleen ;
Wurnig, Moritz C. ;
Frauenfelder, Thomas ;
Boss, Andreas .
INVESTIGATIVE RADIOLOGY, 2017, 52 (07) :434-440
[4]   Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 242 (01) :109-119
[5]   Deep Learning: A Primer for Radiologists [J].
Chartrand, Gabriel ;
Cheng, Phillip M. ;
Vorontsov, Eugene ;
Drozdzal, Michal ;
Turcotte, Simon ;
Pal, Christopher J. ;
Kadoury, Samuel ;
Tang, An .
RADIOGRAPHICS, 2017, 37 (07) :2113-2131
[6]   Low-dose CT via convolutional neural network [J].
Chen, Hu ;
Zhang, Yi ;
Zhang, Weihua ;
Liao, Peixi ;
Li, Ke ;
Zhou, Jiliu ;
Wang, Ge .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02) :679-694
[7]   When Machines Think: Radiology's Next Frontier [J].
Dreyer, Keith J. ;
Geis, J. Raymond .
RADIOLOGY, 2017, 285 (03) :713-718
[8]  
Fan Y, 2012, IEEE NUCL SCI CONF R, P3641
[9]   State of the Art: Iterative CT Reconstruction Techniques [J].
Geyer, Lucas L. ;
Schoepf, U. Joseph ;
Meinel, Felix G. ;
Nance, John W., Jr. ;
Bastarrika, Gorka ;
Leipsic, Jonathon A. ;
Paul, Narinder S. ;
Rengo, Marco ;
Laghi, Andrea ;
De Cecco, Carlo N. .
RADIOLOGY, 2015, 276 (02) :338-356
[10]   Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507