Design and Implementation of Hybrid Active Power Filter (Hapf) for UPS System

被引:1
|
作者
Kumar, Mahendar [1 ]
Memon, Zubair . A. [1 ]
Uqaili, M. . Aslam [1 ]
机构
[1] Mehran Univ Engn & Technol MUET, Inst Informat & Commun Technol IICT, Jamshoro Sindh 76090, Pakistan
来源
INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING | 2020年 / 12卷 / 06期
关键词
UPS; HAPF; d-q theorem; Reference Current; V-dc Bus Regulator; HARMONIC DISTORTION; MITIGATION; CONVERTER;
D O I
10.30880/ijie.2020.12.06.026
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Hybrid Active Power Filter (HAPF) is designed and applied for Uninterrupted Power Supply (UPS) System to mitigate harmonic currents in UPS during the power conversion from rectifiers to inverters (AC-DC-AC Converters). Various UPS types and topologies are used for continuous power supply without delay and protection to connected loads. In spite of the fact that UPS is one of the power quality apparatus but it has also drawback of disturbing the power system quality of system by current harmonics and voltage distortion during conversion of power. Passive and EMI Filters could not eliminate harmonics effectively from UPS system therefore it requires modern, rapid filtering method as well combination of Active and Passive Filters. Proposed model of HAPF for UPS System could mitigate current harmonics for optimal power transfer and minimize losses, increase overall efficiency, reliability and life span of equipment. Higher harmonic current and higher voltage distortion leads to greater power loss. In this paper the (d-q) theorem is applied for the identification of harmonic currents. The d-q theorem and calculation creates the signal of reference compensation current and this produced signal of current is tracked by the yield current of the voltage source converter.. Hysteresis based controller for HAPF is applied to create the switching signals to regulate and maintain the voltage source converter output currents. Harmonics and efficiencies are analyzed at different loads and on charging and discharging of batteries of various UPS System in different industries and sectors on the basis of experimental investigation then HAPF is designed and implemented. In simulation results, it is observed that THD reduced from 46 to 10%, the harmonic currents were compensated and eliminated effectively which improved power quality of UPS System. Furthermore, addition of proposed HAPF could save the power up to 15 % which lost due to poor power quality of UPS System.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 50 条
  • [1] Design and Analysis of Single-phase Adaptive Passive Part coupling Hybrid Active Power Filter (HAPF)
    Wang, Lei
    Pang, Ying
    Lam, Chi-Seng
    Deng, Jian-Yang
    Wong, Man-Chung
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 3615 - 3620
  • [2] Design, Implementation and Field Test of a Novel Hybrid Active Power Filter
    Han, Yang
    Khan, Muhammad Mansoor
    Yao, Gang
    Zhou, Li-Dan
    Chen, Chen
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 651 - 656
  • [3] Design and Implementation of an Active Power Filter
    Huang, Jiaoying
    Gao, Cheng
    Yuan, Haiwen
    Zou, Hang
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 1397 - +
  • [4] Laboratory Implementation of a Hybrid Series Active Power Filter System Part II: Series Active filter designing
    Djeghloud, H.
    Larakeb, M.
    Bentounsi, A.
    Terriche, Y.
    Kerdoun, D.
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 1047 - 1052
  • [5] Design and simulation of hybrid active power filter
    Xia, Xiangyang
    Luo, An
    Zhuo, Ke
    Gaodianya Jishu/High Voltage Engineering, 2006, 32 (02): : 67 - 69
  • [6] Converter Rating Reduction in Hybrid Active Power Filters (HAPF)
    Aminoroaya, Iman
    Karshenas, Hamid R.
    Bakhshai, Alireza
    Jain, Praveen
    2011 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2011, : 1113 - 1118
  • [7] Analysis, Design, and Implementation of Multi-Quasi-Proportional-Resonant Controller for Thyristor-Controlled LC-Coupling Hybrid Active Power Filter (TCLC-HAPF)
    Sou, Wai-Kit
    Chao, Chi-Wa
    Gong, Cheng
    Lam, Chi-Seng
    Wong, Chi-Kong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (01) : 29 - 40
  • [8] Design of high power parallel hybrid active power filter
    Chen, Ji-Cheng
    Qian, Zhao-Ming
    Lu, Zheng-Yu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2001, 21 (SUPPL.): : 225 - 228
  • [9] Modeling and Parameter Design of Thyristor-Controlled LC-Coupled Hybrid Active Power Filter (TCLC-HAPF) for Unbalanced Compensation
    Wang, Lei
    Lam, Chi-Seng
    Wong, Man-Chung
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (03) : 1827 - 1840
  • [10] DESIGN CONSIDERATIONS FOR SERIES HYBRID ACTIVE POWER FILTER
    陈国柱
    吕征宇
    钱照明
    JournalofZhejiangUniversityScience, 2001, (03) : 74 - 78