Development of a robust, fast screening method for the potentiometric determination of iodide in urine and salt samples

被引:22
作者
Machado, Ana [1 ,2 ]
Mesquita, Raquel B. R. [1 ,3 ]
Oliveira, Sara [1 ]
Bordalo, Adriano A. [1 ,2 ]
机构
[1] Univ Porto, ICBAS, Rua Jorge Viterbo Ferreira 228, P-4050313 Porto, Portugal
[2] Univ Porto, Ctr Interdisciplinar Invest Marinha & Ambiental, CIIMAR CIMAR, Au Gen Norton Matos, P-4050208 Matosinhos, Portugal
[3] Univ Catolica Portuguesa, CBQF, Lab Associado, Escola Super Biotecnol, Rua Arquiteto Lobao Vital,Apartado 2511, P-4202401 Porto, Portugal
关键词
Iodide and iodate bi-parametric determination; Potentiometric detection; Urine samples; Salt samples; ELECTROCHEMICAL DETECTION; QUANTIFICATION; GOLD;
D O I
10.1016/j.talanta.2017.03.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a potentiometric flow injection method is described for the fast bi-parametric determination of iodide and iodate in urine and salt samples. The developed methodology aimed for iodine speciation with a potentially portable system (running on batteries). The iodate reduction to iodide was effectively attained in line within the same manifold. The iodide determination was accomplished in the dynamic range of 2.50x10(-6) - 1.00x10(-3) M and the total iodine dynamic range, resulted from iodide plus iodate, was 3.50x10(-6) - 2.00x10(-3) M. The calculated limits of detection were 1.39x10(-6) M and 1.77x10(-6) M for iodide and iodate, respectively. A determination rate of 21 h(-1) for the bi-parametric iodide and iodate determination was obtained for sample injection. The urine samples (RSD < 5.8% for iodide and RSD < 7.0% for iodate) results were in agreement with those obtained by the classic Sandell-Kolthoff reaction colorimetric reference procedure (RD < 7.0%) and standard samples from Centers for Disease Control and Prevention, Atlanta, USA (CDC) international inter-laboratory EQUIP program. The developed flow method was also successfully applied to the iodide and iodate determination in salt samples (RSD <3.1% for iodate and iodide), with comparable results to conventional procedures. No significant interferences were observed interference percentage < 9% for both determinations.
引用
收藏
页码:688 / 694
页数:7
相关论文
共 16 条
[1]   A simple artificial urine for the growth of urinary pathogens [J].
Brooks, T ;
Keevil, CW .
LETTERS IN APPLIED MICROBIOLOGY, 1997, 24 (03) :203-206
[2]   Sensitive quantification of iodide by ion-exchange chromatography with electrochemical detection at a modified platinum electrode [J].
Cataldi, TRI ;
Rubino, A ;
Ciriello, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (01) :134-141
[3]   Comparison of silver, gold and modified platinum electrodes for the electrochemical detection of iodide in urine samples following ion chromatography [J].
Cataldi, TRI ;
Rubino, A ;
Laviola, MC ;
Ciriello, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (02) :224-231
[4]   Carbon dots-based fluorescent probes for sensitive and selective detection of iodide [J].
Du, Fangkai ;
Zeng, Fang ;
Ming, Yunhao ;
Wu, Shuizhu .
MICROCHIMICA ACTA, 2013, 180 (5-6) :453-460
[5]  
Dunn J. T., 1993, METHODS MEASURING IO
[6]  
Hanna Instruments, IOD ION SEL EL INSTR
[7]   Ten Repeat Collections for Urinary Iodine from Spot Samples or 24-Hour Samples Are Needed to Reliably Estimate Individual Iodine Status in Women [J].
Koenig, Franziska ;
Andersson, Maria ;
Hotz, Karin ;
Aeberli, Isabelle ;
Zimmermann, Michael B. .
JOURNAL OF NUTRITION, 2011, 141 (11) :2049-2054
[8]   Gold nanoelectrode ensembles for direct trace electroanalysis of iodide [J].
Pereira, Francisco C. ;
Moretto, Ligia M. ;
De Leo, Manuela ;
Zanoni, Maria V. Boldrin ;
Ugo, Paolo .
ANALYTICA CHIMICA ACTA, 2006, 575 (01) :16-24
[9]   Day-to-day and within-day variation in urinary iodine excretion [J].
Rasmussen, LB ;
Ovesen, L ;
Christiansen, E .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (05) :401-407
[10]  
Sandell EB., 1937, MICROCHIM ACTA, V1, P9, DOI [DOI 10.1007/BF01476194, 10.1007/BF01476194]