IBIS: an OR ready open-source platform for image-guided neurosurgery

被引:81
作者
Drouin, Simon [1 ]
Kochanowska, Anna [1 ]
Kersten-Oertel, Marta [1 ]
Gerard, Ian J. [1 ]
Zelmann, Rina [1 ]
De Nigris, Dante [1 ]
Beriault, Silvain [1 ]
Arbel, Tal [1 ]
Sirhan, Denis [1 ]
Sadikot, Abbas F. [1 ]
Hall, Jeffery A. [1 ]
Sinclair, David S. [1 ]
Petrecca, Kevin [1 ]
DelMaestro, Rolando F. [1 ]
Collins, D. Louis [1 ]
机构
[1] Montreal Neurol Hosp & Inst, McConnell Brain Imaging Ctr, WB 221,3801 Univ St, Montreal, PQ H3A 2B4, Canada
关键词
Image-guided surgery; Ultrasound; Augmented reality; Brain shift correction; ULTRASOUND-CT REGISTRATION; MAGNETIC-RESONANCE IMAGES; DEEP BRAIN-STIMULATION; 3-DIMENSIONAL ULTRASOUND; NONRIGID REGISTRATION; RIGID REGISTRATION; VISUALIZATION; TOOLKIT; VOLUME; VERTEBRAE;
D O I
10.1007/s11548-016-1478-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Navigation systems commonly used in neurosurgery suffer from two main drawbacks: (1) their accuracy degrades over the course of the operation and (2) they require the surgeon to mentally map images from the monitor to the patient. In this paper, we introduce the Intraoperative Brain Imaging System (IBIS), an open-source image-guided neurosurgery research platform that implements a novel workflow where navigation accuracy is improved using tracked intraoperative ultrasound (iUS) and the visualization of navigation information is facilitated through the use of augmented reality (AR). The IBIS platform allows a surgeon to capture tracked iUS images and use them to automatically update preoperative patient models and plans through fast GPU-based reconstruction and registration methods. Navigation, resection and iUS-based brain shift correction can all be performed using an AR view. IBIS has an intuitive graphical user interface for the calibration of a US probe, a surgical pointer as well as video devices used for AR (e.g., a surgical microscope). The components of IBIS have been validated in the laboratory and evaluated in the operating room. Image-to-patient registration accuracy is on the order of and can be improved with iUS to a median target registration error of 2.54 mm. The accuracy of the US probe calibration is between 0.49 and 0.82 mm. The average reprojection error of the AR system is . The system has been used in the operating room for various types of surgery, including brain tumor resection, vascular neurosurgery, spine surgery and DBS electrode implantation. The IBIS platform is a validated system that allows researchers to quickly bring the results of their work into the operating room for evaluation. It is the first open-source navigation system to provide a complete solution for AR visualization.
引用
收藏
页码:363 / 378
页数:16
相关论文
共 57 条
[1]   World Medical Association Declaration of Helsinki Ethical Principles for Medical Research Involving Human Subjects [J].
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (20) :2191-2194
[2]   CustusX: an open-source research platform for image-guided therapy [J].
Askeland, Christian ;
Solberg, Ole Vegard ;
Bakeng, Janne Beate Lervik ;
Reinertsen, Ingerid ;
Tangen, Geir Arne ;
Hofstad, Erlend Fagertun ;
Iversen, Daniel Hoyer ;
Vapenstad, Cecilie ;
Selbekk, Tormod ;
Lango, Thomas ;
Hernes, Toril A. Nagelhus ;
Leira, Hakon Olav ;
Unsgard, Geirmund ;
Lindseth, Frank .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (04) :505-519
[3]  
Beriault Silvain, 2013, Clinical Image-Based Procedures. From Planning to Intervention. International Workshop, CLIP 2012 Held in Conjunction with MICCAI 2012. Revised Selected Papers, P42, DOI 10.1007/978-3-642-38079-2_6
[4]   Automatic SWI Venography Segmentation Using Conditional Random Fields [J].
Beriault, Silvain ;
Xiao, Yiming ;
Collins, D. Louis ;
Pike, G. Bruce .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (12) :2478-2491
[5]   Neuronavigation using susceptibility-weighted venography: application to deep brain stimulation and comparison with gadolinium contrast [J].
Beriault, Silvain ;
Sadikot, Abbas F. ;
Alsubaie, Fahd ;
Drouin, Simon ;
Collins, D. Louis ;
Pike, G. Bruce .
JOURNAL OF NEUROSURGERY, 2014, 121 (01) :131-141
[6]  
Bériault S, 2012, LECT NOTES COMPUT SC, V7510, P487, DOI 10.1007/978-3-642-33415-3_60
[7]   A multi-modal approach to computer-assisted deep brain stimulation trajectory planning [J].
Beriault, Silvain ;
Al Subaie, Fahd ;
Collins, D. Louis ;
Sadikot, Abbas F. ;
Pike, G. Bruce .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (05) :687-704
[8]   STEREOTACTIC HEAD FRAME FOR USE WITH CT BODY SCANNERS [J].
BROWN, RA .
INVESTIGATIVE RADIOLOGY, 1979, 14 (04) :300-304
[9]   3D interactive tractography-informed resting-state fMRI connectivity [J].
Chamberland, Maxime ;
Bernier, Michael ;
Fortin, David ;
Whittingstall, Kevin ;
Descoteaux, Maxime .
FRONTIERS IN NEUROSCIENCE, 2015, 9
[10]   Real-time multi-peak tractography for instantaneous connectivity display [J].
Chamberland, Maxime ;
Whittingstall, Kevin ;
Fortin, David ;
Mathieu, David ;
Descoteaux, Maxime .
FRONTIERS IN NEUROINFORMATICS, 2014, 8