In Situ Determination of Nitrate in Water Using Fourier Transform Mid-Infrared Attenuated Total Reflectance Spectroscopy Coupled with Deconvolution Algorithm

被引:25
作者
Gan, Fangqun [1 ,2 ]
Wu, Ke [2 ]
Ma, Fei [1 ]
Du, Changwen [1 ,3 ]
机构
[1] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Peoples R China
[2] Jiangsu Open Univ, Coll Environm & Ecol, Nanjing 210017, Peoples R China
[3] Univ Chinese Acad Sci, Coll Adv Agr Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
nitrate; water bodies; Fourier transform attenuated total reflection; deconvolution; curve-fitting; partial least squares; VARIABLE SELECTION; RAPID-DETERMINATION; SOIL;
D O I
10.3390/molecules25245838
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Fourier transform infrared attenuated total reflectance (FTIR-ATR) spectroscopy has been used to determine the nitrate content in aqueous solutions. However, the conventional water deduction algorithm indicated considerable limits in the analysis of samples with low nitrate concentration. In this study, FTIR-ATR spectra of nitrate solution samples with high and low concentrations were obtained, and the spectra were then pre-processed with deconvolution curve-fitting (without water deduction) combined with partial least squares regression (PLSR) to predict the nitrate content. The results show that the typical absorption of nitrate (1200-1500 cm(-1)) did not clearly align with the conventional algorithm of water deduction, while this absorption was obviously observed through the deconvolution algorithm. The first principal component of the spectra, which explained more than 95% variance, was linearly related to the nitrate content; the correlation coefficient (R-2) of the PLSR model for the high-concentration group was 0.9578, and the ratio of the standard deviation of the prediction set to that of the calibration set (RPD) was 4.22, indicating excellent prediction performance. For the low-concentration group model, R-2 and RPD were 0.9865 and 3.15, respectively, which also demonstrated significantly improved prediction capability. Therefore, FTIR-ATR spectroscopy combined with deconvolution curve-fitting can be conducted to determine the nitrate content in aqueous solutions, thus facilitating rapid determination of nitrate in water bodies with varied concentrations.
引用
收藏
页数:9
相关论文
共 32 条
[1]  
Anjali Verma Anjali Verma, 2014, Current World Environment, V9, P114, DOI 10.12944/CWE.9.1.17
[2]  
[Anonymous], 2006, GEODERMA
[3]   Biodiesel classification by base stock type (vegetable oil) using near infrared spectroscopy data [J].
Balabin, Roman M. ;
Safieva, Ravilya Z. .
ANALYTICA CHIMICA ACTA, 2011, 689 (02) :190-197
[4]  
Barth A., 2009, Biological and Biomedical Infrared Spectroscopy
[5]   Analysis of the Structure of the Bands in the IR Spectrum of β-D Glucose by the Regularized Method of Deconvolution [J].
Buslov, D.K. ;
Nikonenko, N.A. ;
Sushko, N.I. ;
Zhbankov, R.G. .
Journal of Applied Spectroscopy, 2002, 69 (06) :817-824
[6]   Regularized method of spectral curve deconvolution [J].
Buslov, DK ;
Nionenko, NA .
APPLIED SPECTROSCOPY, 1997, 51 (05) :666-672
[7]  
China Soil Society Agrochemistry Speciality Committee, 1989, AGR CONV AN, P91
[8]   Measuring dermal exposure to pesticide residues with attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy [J].
Doran, EM ;
Yost, MG ;
Fenske, RA .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2000, 64 (05) :666-672
[9]  
Du CW, 2007, CHINESE J ANAL CHEM, V35, P119
[10]   Determination of soil properties using Fourier transform mid-infrared photoacoustic spectroscopy [J].
Du, Changwen ;
Zhou, Jianmin ;
Wang, Huoyan ;
Chen, Xiaoqin ;
Zhu, Anning ;
Zhang, Jiabao .
VIBRATIONAL SPECTROSCOPY, 2009, 49 (01) :32-37