Reproducibility of shear wave elastography among operators, machines, and probes in an elasticity phantom

被引:22
作者
Alrashed, Abdulaziz Ibrahim [1 ]
Alfuraih, Abdulrahman M. [2 ]
机构
[1] Prince Sultan Mil Med City, Radiodiagnost & Med Imaging Dept, Riyadh, Saudi Arabia
[2] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Kharj, Saudi Arabia
关键词
Phantoms; Elasticity imaging techniques; Ultrasonography; Reproducibility of results; Transducers; ULTRASOUND ELASTOGRAPHY; WFUMB GUIDELINES; CLINICAL-USE; RECOMMENDATIONS; VARIABILITY; ACCURACY; SYSTEMS; STRAIN;
D O I
10.14366/usg.20011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study was aimed to investigate the reproducibility of shear wave elastography (SWE) among operators, machines, and probes in a phantom, and to evaluate the effect of depth of the embedded inclusions and the accuracy of the measurements. Methods: In vitro stiffness measurements were made of six inclusions (10, 40, and 60 kPa) embedded at two depths (1.5 cm and 5 cm) in an elastography phantom. Measurements were obtained by two sonographers using two ultrasound machines (the SuperSonic Imagine Aixplorer with the XC6-1, SL10-2 and SL18-5 probes, and the General Electric LOGIQ E9 with the 9L-D probe). Variability was evaluated using the coefficient of variation. Reproducibility was calculated using intraclass correlation coefficients (ICCs). Results: For shallow inclusions, low variability was observed between operators (range, 0.9% to 5.4%). However, the variability increased significantly for deep inclusions (range, 2.4% to 80.8%). The measurement difference between the operators was 1%-15% for superficial inclusions and 3%-43% for deep inclusions. Inter-operator reproducibility was almost perfect (ICC>0.90). The measurement difference between machines was 0%-15% for superficial inclusions and 38.6%-82.9% for deep inclusions. For superficial inclusions, the reproducibility among the three probes was excellent (ICC>0.97). The mean stiffness values of the 10 kPa inclusion were overestimated by 16%, while those of the 40 kPa and 60 kPa inclusions were underestimated by 42% and 48%, respectively. Conclusion: Phantom SWE measurements were only reproducible among operators, machines, and probes at superficial depths. SWE measurements acquired in deep regions should not be used interchangeably among operators, machines, or probes.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 37 条
[1]   The effect of unit, depth, and probe load on the reliability of muscle shear wave elastography: Variables affecting reliability of SWE [J].
Alfuraih, Abdulrahman M. ;
O'Connor, Philip ;
Hensor, Elizabeth ;
Tan, Ai Lyn ;
Emery, Paul ;
Wakefield, Richard J. .
JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (02) :108-115
[2]   An investigation into the variability between different shear wave elastography systems in muscle [J].
Alfuraih, Abdulrahman M. ;
O'Connor, Phil ;
Tan, Ai Lyn ;
Hensor, Elizabeth M. A. ;
Emery, Paul ;
Wakefield, Richard J. .
MEDICAL ULTRASONOGRAPHY, 2017, 19 (04) :392-400
[3]  
[Anonymous], 2020, EL QA PHANT MOD 049
[4]  
[Anonymous], 2013, MULT MULT ULTR PHANT
[5]  
Bercoff J., 2008, Shearwave elastography"
[6]  
Brown C.E., 1998, Springer eBooks, P155, DOI [10.1007/978-3-642-80328-4_13, DOI 10.1007/978-3-642-80328-4_13, DOI 10.1007/978-3-642-80328-4]
[7]   A Comparative Study of Strain and Shear-Wave Elastography in an Elasticity Phantom [J].
Carlsen, Jonathan F. ;
Pedersen, Malene R. ;
Ewertsen, Caroline ;
Saftoiu, Adrian ;
Lonn, Lars ;
Rafaelsen, Soren R. ;
Nielsen, Michael B. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) :W236-W242
[8]   Variability of ShearWave Velocity using Different Frequencies in Acoustic Radiation Force Impulse (ARFI) Elastography: A Phantom and Normal Liver Study [J].
Chang, S. ;
Kim, M. -J. ;
Kim, J. ;
Lee, M. -J. .
ULTRASCHALL IN DER MEDIZIN, 2013, 34 (03) :260-265
[9]   WFUMB GUIDELINES AND RECOMMENDATIONS ON THE CLINICAL USE OF ULTRASOUND ELASTOGRAPHY: PART 4. THYROID [J].
Cosgrove, David ;
Barr, Richard ;
Bojunga, Joerg ;
Cantisani, Vito ;
Chammas, Maria Cristina ;
Dighe, Manjiri ;
Vinayak, Sudhir ;
Xu, Jun-Mei ;
Dietrich, Christoph F. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01) :4-26
[10]   Clinical utilization of shear wave elastography in the musculoskeletal system [J].
Davis, Leah C. ;
Baumer, Timothy G. ;
Bey, Michael J. ;
van Holsbeeck, Marnix .
ULTRASONOGRAPHY, 2019, 38 (01) :2-12