Comparative analysis of odorous volatile organic compounds between direct injection and solid-phase microextraction: Development and validation of a gas chromatography-mass spectrometry-based methodology

被引:12
作者
Pandey, Sudhir Kumar [1 ]
Kim, Ki-Hyun [1 ]
机构
[1] Sejong Univ, Dept Earth & Environm Sci, Atmospher Environm Lab, Seoul 143747, South Korea
关键词
Gas chromatography with mass spectrometry; Odorants; Solid-phase microextraction; Volatile organic compounds; Environmental air samples; GASEOUS REDUCED SULFUR; AIR; SYSTEM; ATMOSPHERE; FIBERS;
D O I
10.1016/j.chroma.2009.05.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, the feasibility of GC-MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC-MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002-0.007 ng) and SPME method (1.03-1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol(-1)) relative to the DI method (similar to 6-15 nmol mol(-1)). The reliability of the GC-MS method was further validated through an analysis of real environmental samples collected from an industrial area. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5436 / 5444
页数:9
相关论文
共 38 条
[1]  
Agency for Toxic Substances and Disease Registry (ATSDR), 1992, TOX PROF BOR, P1
[2]   Odor as an Aid to Chemical Safety: Odor Thresholds Compared with Threshold Limit Values and Volatilities for 214 Industrial Chemicals in Air and Water Dilution [J].
Amoore, John E. ;
Hautala, Earl .
JOURNAL OF APPLIED TOXICOLOGY, 1983, 3 (06) :272-290
[3]  
[Anonymous], 1989, OD THRESH CHEM EST O
[4]  
[Anonymous], 2003, Standard Operating Procedure for the Digestion of Aqueous and Solid Samples Using Method 200.2 Hotblock Digestion Technique Method 200.2, Metal Methods 025, Region 5, Chicago, P1
[5]  
*ATSDR, 2001, FACT SHEET TOL
[6]  
*ATSDR, 1997, TOX PROF BE IN PRESS
[7]  
*ATSDR, 2007, FACT SHEET XYL
[8]   Analysis of industrial contaminants in indoor air: Part 1. Volatile organic compounds, carbonyl compounds, polycyclic aromatic hydrocarbons and polychlorinated biphenyls [J].
Barro, Ruth ;
Regueiro, Jorge ;
Llompart, Maria ;
Garcia-Jares, Carmen .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (03) :540-566
[9]   Use of poly(ethylene terephtalate) film bag to sample and remove humidity from atmosphere containing volatile organic compounds [J].
Beghi, Sandra ;
Guillot, Jean-Michel .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1183 (1-2) :1-5
[10]   Comparative evaluation of liquid chromatography versus gas chromatography using a β-cyclodextrin stationary phase for the determination of BTEX in occupational environments [J].
Campos-Candel, Andreu ;
Llobat-Estelles, Maria ;
Mauri-Aucejo, Adela .
TALANTA, 2009, 78 (4-5) :1286-1292