Determination of optimal intravenous contrast agent iodine dose for the detection of liver metastasis at 80-kVp CT

被引:16
作者
Goshima, Satoshi [1 ]
Kanematsu, Masayuki [1 ]
Noda, Yoshifumi [1 ]
Kondo, Hiroshi [1 ]
Watanabe, Haruo [1 ]
Kawada, Hiroshi [1 ]
Kawai, Nobuyuki [1 ]
Tanahashi, Yukichi [1 ]
Bae, Kyongtae T. [2 ]
机构
[1] Gifu Univ Hosp, Dept Radiol, Gifu 5011194, Japan
[2] Univ Pittsburgh, Dept Radiol, Med Ctr, Pittsburgh, PA 15260 USA
关键词
Liver; CT; Metastasis; Contrast; LOW-TUBE-VOLTAGE; ITERATIVE RECONSTRUCTION ALGORITHM; IMAGE QUALITY; PATIENT WEIGHT; ABDOMINAL CT; DYNAMIC CT; ENHANCEMENT;
D O I
10.1007/s00330-014-3227-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the optimal iodine mass (IM) to achieve a 50-HU increase in hepatic attenuation for the detection of liver metastasis based on total body weight (TBW) or body surface area (BSA) at 80-kVp computed tomography (CT) imaging of the liver. One-hundred and fifty patients who underwent contrast-enhanced CT at 80-kVp were randomised into three groups: 0.5 gI/kg, 0.4 gI/kg and 0.3 gI/kg. Portal venous phase images were evaluated for hepatic parenchymal enhancement (a dagger HU) and visualisation of liver metastasis. Iodine mass per BSA (gI/m(2)) calculated in individual patients were evaluated. Mean a dagger HU for the 0.5 gI/kg group (84.2 HU) was higher than in the 0.4 gI/kg (66.1 HU) and 0.3 gI/kg (53.7 HU) groups (P < 0.001). Linear correlation equations between a dagger HU and IM per TBW or BSA are a dagger HU = 7.0 + 153.0 x IM/TBW (r = 0.73, P < 0.001) and a dagger HU = 11.4 + 4.0 x IM/BSA (r = 0.75, P < 0.001), respectively. The three groups were comparable for the visualisation of hepatic metastases. The iodine mass to achieve a 50-HU increase in hepatic attenuation at 80-kVp CT was estimated to be 0.28 gI/kg of body weight or 9.6 gI/m(2) of body surface area. aEuro cent Hepatic enhancement is expressed as a dagger HU = 7.0 + 153.0 x IM [g]/TBW [kg]. aEuro cent Hepatic enhancement is expressed as a dagger HU = 11.4 + 4.0 x IM [g]/BSA [m (2) ]. aEuro cent Essential iodine dose at 80-kVp CT was 0.28 gI/kg or 9.6 gI/m (2) .
引用
收藏
页码:1853 / 1859
页数:7
相关论文
共 18 条
[1]   Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CV [J].
Awai, K ;
Takada, K ;
Onishi, H ;
Hori, S .
RADIOLOGY, 2002, 224 (03) :757-763
[2]   Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model [J].
Bae, KT .
RADIOLOGY, 2003, 227 (03) :809-816
[3]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[4]   Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity [J].
Bae, Kyongtae T. ;
Seeck, Brian A. ;
Hildebolt, Charles F. ;
Tao, Cheng ;
Zhu, Fang ;
Kanematsu, Masayuki ;
Woodard, Pamela K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :777-784
[5]   QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING [J].
BROOKS, RA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) :487-493
[6]  
Goshima Satoshi, 2006, AJR Am J Roentgenol, V187, pW25, DOI 10.2214/AJR.04.1878
[7]   DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
CROWE, TM ;
GAINES, MV .
RADIOLOGY, 1995, 195 (02) :353-357
[8]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[9]   Techniques and applications of automatic tube current modulation for CT [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Schmidt, B ;
Westerman, BL ;
Morgan, HT ;
Saini, S .
RADIOLOGY, 2004, 233 (03) :649-657
[10]   Body size indices to determine iodine mass with contrast-enhanced multi-detector computed tomography of the upper abdomen: does body surface area outperform total body weight or lean body weight? [J].
Kondo, Hiroshi ;
Kanematsu, Masayuki ;
Goshima, Satoshi ;
Watanabe, Haruo ;
Kawada, Hiroshi ;
Moriyama, Noriyuki ;
Bae, Kyongtae T. .
EUROPEAN RADIOLOGY, 2013, 23 (07) :1855-1861