Long axial imaging range using conventional swept source lasers in optical coherence tomography via re-circulation loops

被引:0
作者
Bradu, Adrian [1 ]
Jackson, David A. [1 ]
Podoleanu, Adrian [1 ]
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
来源
2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES | 2018年 / 10591卷
基金
英国工程与自然科学研究理事会;
关键词
optical coherence tomography; re-circulation rings; long axial range; coherence length; 1310; NM;
D O I
10.1117/12.2282116
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Typically, swept source optical coherence tomography (SS-OCT) imaging instruments are capable of a longer axial range than their camera based (CB) counterpart. However, there are still various applications that would take advantage for an extended axial range. In this paper, we propose an interferometer configuration that can be used to extend the axial range of the OCT instruments equipped with conventional swept-source lasers up to a few cm. In this configuration, the two arms of the interferometer are equipped with adjustable optical path length rings. The use of semiconductor optical amplifiers in the two rings allows for compensating optical losses hence, multiple paths depth reflectivity profiles (A-scans) can be combined axially. In this way, extremely long overall axial ranges are possible. The use of the re-circulation loops produces an effect equivalent to that of extending the coherence length of the swept source laser. Using this approach, the achievable axial imaging range in SS-OCT can reach values well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters. In the present work, we demonstrate axial ranges exceeding 4 cm using a commercial swept source laser and reaching 6 cm using an "in-house" swept source laser. When used in a conventional set-up alone, both these lasers can provide less than a few mm axial range.
引用
收藏
页数:5
相关论文
共 3 条
[1]   Swept source optical coherence microscopy using a 1310 nm VCSEL light source [J].
Ahsen, Osman O. ;
Tao, Yuankai K. ;
Potsaid, Benjamin M. ;
Sheikine, Yuri ;
Jiang, James ;
Grulkowski, Ireneusz ;
Tsai, Tsung-Han ;
Jayaraman, Vijaysekhar ;
Kraus, Martin F. ;
Connolly, James L. ;
Hornegger, Joachim ;
Cable, Alex ;
Fujimoto, James G. .
OPTICS EXPRESS, 2013, 21 (15) :18021-18033
[2]   Akinetic all-semiconductor programmable swept-source at 1550 nm and 1310 nm with centimeters coherence length [J].
Bonesi, M. ;
Minneman, M. P. ;
Ensher, J. ;
Zabihian, B. ;
Sattmann, H. ;
Boschert, P. ;
Hoover, E. ;
Leitgeb, R. A. ;
Crawford, M. ;
Drexler, W. .
OPTICS EXPRESS, 2014, 22 (03) :2632-2655
[3]   Extra long imaging range swept source optical coherence tomography using re-circulation loops [J].
Bradu, Adrian ;
Neagu, Liviu ;
Podolcanu, Adrian .
OPTICS EXPRESS, 2010, 18 (24) :25361-25370