Efficient Bregman Iteration in fully 3D PET

被引:0
|
作者
Szirmay-Kalos, Laszlo [1 ]
Toth, Balazs [1 ]
Jakab, Gabor [2 ]
机构
[1] Budapest Univ Technol & Econ, Budapest, Hungary
[2] Mediso Ltd, Budapest, Hungary
来源
2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2014年
关键词
ALGORITHMS;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Positron Emission Tomography reconstruction is ill posed. The result obtained with the iterative ML-EM algorithm is often noisy, which can be controlled by regularization. Common regularization methods penalize high frequency features or the total variation, thus they compromise even valid solutions that have such properties. Bregman iteration offers a better choice enforcing regularization only where needed by the noisy data. Bregman iteration requires a nested optimization, which poses problems when the algorithm is implemented on the GPU where storage space is limited and data transfer is slow. Another problem is that the strength of the regularization is set by a single global parameter, which results in overregularization for voxels measured by fewer LORs. To handle these problems, we propose a modified scheme that merges the two optimization steps into one, eliminating the overhead of Bregman iteration. The algorithm is demonstrated for a 2D test scenario and also in fully 3D reconstruction. The benefits over TV regularization are particularly high if the data has higher variation and point like features. The proposed algorithm is built into the TeraTomo (TM) system.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Efficient Point Clouds Based Scatter Correction for Fully 3D PET
    Gao, Fei
    Xu, Jingjia
    Liu, Huafeng
    Shi, Pengcheng
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2931 - 2934
  • [2] A FULLY 3D SMALL PET SCANNER
    TAVERNIER, S
    BRUYNDONCKX, P
    SHUPING, Z
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 635 - 643
  • [3] Fully 3D GPU PET reconstruction
    Herraiz, J. L.
    Espana, S.
    Cal-Gonzalez, J.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S169 - S171
  • [4] Optimization of a fully 3D single scatter simulation algorithm for 3D PET
    Accorsi, R
    Adam, LE
    Werner, ME
    Karp, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2577 - 2598
  • [5] DETECTOR EFFICIENCY AND COMPTON SCATTER IN FULLY 3D PET
    OLLINGER, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1168 - 1173
  • [7] Experience with fully 3D PET and implications for future high-resolution 3D tomographs
    Bailey, DL
    Miller, MP
    Spinks, TJ
    Bloomfield, PM
    Livieratos, L
    Young, HE
    Jones, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 777 - 786
  • [8] FULLY 3D PET IMAGE-RECONSTRUCTION WITH PLANE INTEGRALS
    WU, C
    CHEN, CT
    GUNTER, DL
    ORDONEZ, CE
    RADIOLOGY, 1992, 185 : 252 - 252
  • [9] Attenuation and scatter correction in fully 3D limited angle PET
    Pönisch, F
    Enghardt, W
    Lauckner, K
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2115 - 2118
  • [10] The effect of energy threshold on image variance in fully 3D pet
    Ollinger, JM
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 269 - 276