Comparison of early haemodynamics of 19-mm aortic valve bioprostheses in patients with a small aortic annulus

被引:19
作者
Domoto, Satoru [1 ]
Niinami, Hiroshi [1 ]
Uwabe, Kazuhiko [1 ]
Koike, Hiroyuki [1 ]
Tabata, Mimiko [1 ]
Morita, Kozo [1 ]
Kambe, Masaru [1 ]
Iguchi, Atsushi [1 ]
机构
[1] Saitama Med Univ, Saitama Int Med Ctr, Dept Cardiovasc Surg, Hidaka, Saitama, Japan
关键词
Trifecta valve; Aortic valve replacement; Effective orifice area; Pressure gradient; Prosthesis-patient mismatch; LEFT-VENTRICULAR MASS; PERIMOUNT MAGNA; HEART-VALVES; REPLACEMENT; PROSTHESIS; MISMATCH; TRIFECTA; PERFORMANCE; SURVIVAL;
D O I
10.1093/icvts/ivv284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: A potential problem in aortic valve replacement (AVR) for patients with a small aortic annulus is prosthesis-patient mismatch (PPM). Although larger size prostheses have been well studied, the haemodynamics of 19-mm bioprostheses has been reported in only a small number of patients. The Trifecta valve is a novel bioprosthesis and its unique design is conceived to increase effective orifice area (EOA) and prevent PPM. This study aims at comparing the early haemodynamics of the new Trifecta valve with that of other conventional 19-mm valves. METHODS: We retrospectively evaluated 128 consecutive patients who underwent AVR with 19-mm bioprosthesis (39 Trifecta valve, 67 Magna Ease valve and 22 Mosaic Ultra valve) at Saitama International Medical Center between April 2012 and December 2014. Haemodynamics was evaluated by transthoracic echocardiography at 1 month after discharge and at 1-year follow-up. RESULTS: The average body surface area of all patients was 1.37 m(2). There was no difference in postoperative clinical outcomes between the three groups. Among the three groups, the mean pressure gradient (MPG) was the smallest (10.6 +/- 4.3 mmHg, P < 0.001) and the EOA was the largest (1.63 +/- 0.36 cm(2), P < 0.001) in the Trifecta group at 1 month after discharge. In the Trifecta group, PPM was not observed (P < 0.001), the MPG was the smallest (12.8 +/- 3.6 mmHg, P < 0.001) and the EOA was the largest (1.50 +/- 0.30 cm(2), P < 0.001) at the 1-year follow-up. CONCLUSIONS: The new 19-mm Trifecta valve showed favourable early haemodynamics compared with the conventional valves and may be useful for preventing PPM in patients with a small aortic annulus.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 25 条
[1]   Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis [J].
Banbury, MK ;
Cosgrove, DM ;
Thomas, JD ;
Blackstone, EH ;
Rajeswaran, J ;
Okies, JE ;
Frater, RM .
ANNALS OF THORACIC SURGERY, 2002, 73 (05) :1460-1465
[2]   Effect of Valve Design on the Stent Internal Diameter of a Bioprosthetic Valve A Concept of True Internal Diameter and Its Implications for the Valve-in-Valve Procedure [J].
Bapat, Vinayak N. ;
Attia, Rizwan ;
Thomas, Martyn .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (02) :115-127
[3]   The St Jude Medical Trifecta aortic pericardial valve: Results from a global, multicenter, prospective clinical study [J].
Bavaria, Joseph E. ;
Desai, Nimesh D. ;
Cheung, Anson ;
Petracek, Michael R. ;
Groh, Mark A. ;
Borger, Michael A. ;
Schaff, Hartzell V. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (02) :590-597
[4]   Bovine pericardial versus porcine stented replacement aortic valves: Early results of a randomized comparison of the Perimount and the Mosaic valves [J].
Chambers, John B. ;
Rajani, Ronak ;
Parkin, Denise ;
Rimington, Helen M. ;
Blauth, Christopher I. ;
Venn, Graham E. ;
Young, Christopher P. ;
Roxburgh, James C. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05) :1142-1148
[5]  
Dalmau Maria Jose, 2007, Interact Cardiovasc Thorac Surg, V6, P345, DOI 10.1510/icvts.2006.144196
[6]   Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves [J].
Flameng, Willem ;
Herregods, Marie-Christine ;
Vercalsteren, Monique ;
Herijgers, Paul ;
Bogaerts, Kris ;
Meuris, Bart .
CIRCULATION, 2010, 121 (19) :2123-2129
[7]   Comparison of Transcatheter and Surgical Aortic Valve Replacement in Severe Aortic Stenosis [J].
Hahn, Rebecca T. ;
Pibarot, Philippe ;
Stewart, William J. ;
Weissman, Neil J. ;
Gopalakrishnan, Deepika ;
Keane, Martin G. ;
Anwaruddin, Saif ;
Wang, Zuyue ;
Bilsker, Martin ;
Lindman, Brian R. ;
Herrmann, Howard C. ;
Kodali, Susheel K. ;
Makkar, Raj ;
Thourani, Vinod H. ;
Svensson, Lars G. ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. ;
Douglas, Pamela S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (25) :2514-2521
[8]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529
[9]   Hemodynamic performance of the Medtronic Mosaic and Perimount Magna aortic bioprostheses: five-year results of a prospectively randomized study [J].
Jose Dalmau, Maria ;
Gonzalez-Santos, Jose Maria ;
Antonio Blazquez, Jose ;
Alfonso Sastre, Jose ;
Lopez-Rodriguez, Javier ;
Bueno, Maria ;
Castano, Mario ;
Arribas, Antonio .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (06) :844-852
[10]   Patient-Prosthesis Mismatch and Reduction in Left Ventricular Mass After Aortic Valve Replacement [J].
Kandler, Kristian ;
Moller, Christian H. ;
Hassager, Christian ;
Olsen, Peter S. ;
Lilleor, Nikolaj ;
Steinbruchel, Daniel A. .
ANNALS OF THORACIC SURGERY, 2013, 96 (01) :66-71