Comparative analysis between 64-and 320-slice spiral computed tomography in the display of coronary artery stents and diagnosis of in-stent restenosis

被引:10
作者
Yue, Junyan [1 ]
Chen, Jie [1 ]
Dou, Wenguang [1 ]
Hu, Ying [1 ]
Li, Qiang [1 ]
Zhou, Fengmei [1 ]
Cui, Hongkai [1 ]
Wu, Qingwu [1 ]
Yang, Ruimin [1 ]
机构
[1] Xinxiang Med Univ, Affiliated Hosp 1, Imaging Ctr, Weihui 453100, Henan, Peoples R China
关键词
coronary vessels; stents; tomography; computed tomography; in-stent restenosis; CT ANGIOGRAPHY; INITIAL-EXPERIENCE; ACCURACY; PATENCY; IMPLANTATION; FRACTURE; PATIENT;
D O I
10.3892/etm.2015.2768
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to compare the accuracy of 64-multi-slice spiral computed tomography (64-MSCT) and 320-MSCT in the display of coronary artery stents and diagnosis of in-stent restenosis. The data collected from the 64- and 320-MSCT coronary angiography of 93 patients following coronary artery stent implantation were retrospectively analyzed. The 64-MSCT group comprised 30 cases with 57 stents and the 320-MSCT group comprised 63 cases with 93 stents. The image quality, heart rate of the patients and the radiation effective dose (ED) they were subjected to, were compared. Furthermore, the diagnostic abilities of 64-and 320-MSCT coronary angiography for in-stent restenosis were evaluated using invasive coronary angiography results as the gold standards. Statistically significant differences were observed in the heart rate and ED of the patients from the two groups (P<0.05), but no significant difference was identified in the accuracy index (P>0.05). The sensitivity, specificity, positive and negative predictive value and accuracy of the 64-MSCT group were found to be 100% (7/7), 93.94% (31/33); 77.78% (7/9), 100% (31/31) and 95% (38/40), respectively, and those in the 320-MSCT group were found to be 100% (16/16), 95.89% (70/73), 84.21% (16/19), 100% (70/70) and 96.63% (86/89), respectively. The present findings suggest that both 64-MSCT and 320-MSCT can be used for follow-up and curative effect evaluation following coronary stent implantation; however, 320-MS CT has fewer requirements of the patients' heart rate and uses a lower radiation dose.
引用
收藏
页码:1871 / 1876
页数:6
相关论文
共 50 条
  • [21] Coronary artery bypass graft angioplasty conducted by 64-slice spiral computed tomography
    Ochala, Andrzej
    Syzdol, Marcin
    Wieja, Pawel
    Garbocz, Piotr
    Sosnowski, Maciej
    Cybulski, Wieslaw
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2011, 7 (03): : 193 - 198
  • [22] 64-slice computed tomography assessment of coronary artery stents:: a phantom study
    Mahnken, AH
    Mühlenbruch, G
    Seyfarth, T
    Flohr, T
    Stanzel, S
    Wildberger, JE
    Günther, RW
    Kuettner, A
    ACTA RADIOLOGICA, 2006, 47 (01) : 36 - 42
  • [23] Diagnostic accuracy of 64-slice multidetector CT angiography for detection of in-stent restenosis of vertebral artery ostium stents: comparison with conventional angiography
    Lee, Youn Joo
    Lim, Yeon Soo
    Lim, Hyun Wook
    Yoo, Won Jong
    Choi, Byung Gil
    Kim, Bum Soo
    ACTA RADIOLOGICA, 2014, 55 (08) : 1000 - 1007
  • [24] Visualization of coronary arteries and coronary stents by low dose 320-slice multi-detector computed tomography in a patient with atrial fibrillation
    Gaudio, Carlo
    Evangelista, Antonietta
    Pasceri, Vincenzo
    Pannarale, Giuseppe
    Varrica, Salvatore
    Romitelli, Susanna
    Pelliccia, Francesco
    Pellegrini, Massimo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (01) : E6 - E7
  • [25] Detection of in-stent restenosis of coronary stents using 40-detector row computed tomography in vitro
    Suzuki, Shigeru
    Furui, Shigeru
    Kuwahara, Sadatoshi
    Kaminaga, Tatsuro
    Takei, Ryoji
    Isshiki, Takaaki
    Kozuma, Ken
    Aizawa, Tadanori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (02) : 252 - 258
  • [26] Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis
    Tao Dai
    Jiang-rong Wang
    Peng-fei Hu
    European Radiology, 2018, 28 : 1373 - 1382
  • [27] Angiographic patterns of in-stent restenosis classified by computed tomography in patients with drug-eluting stents: correlation with invasive coronary angiography
    Pan, Jingwei
    Lu, Zhigang
    Zhang, Jiayin
    Li, Minghua
    Wei, Meng
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 101 - 107
  • [28] Flat-panel detector computed tomography for the assessment of coronary artery stents -: Phantom study in comparison with 16-slice spiral computed tomography
    Mahnken, AH
    Seyfarth, T
    Flohr, T
    Herzog, C
    Stahl, J
    Stanzel, S
    Kuettner, A
    Wildberger, JE
    Günther, RW
    INVESTIGATIVE RADIOLOGY, 2005, 40 (01) : 8 - 13
  • [29] Evaluation of In-Stent Restenosis After Stent Implantation in the Vertebral Artery Ostium by Multislice Computed Tomography Angiography: Factors Affecting Accurate Diagnosis
    Lee, Y. J.
    Lim, Y. S.
    Lim, H. W.
    Yu, I. K.
    Kim, Y. J.
    Yoo, W. J.
    CLINICAL NEURORADIOLOGY, 2015, 25 (04) : 379 - 386
  • [30] Evaluation of In-Stent Restenosis After Stent Implantation in the Vertebral Artery Ostium by Multislice Computed Tomography Angiography: Factors Affecting Accurate Diagnosis
    Y. J. Lee
    Y. S. Lim
    H. W. Lim
    I. K. Yu
    Y. J. Kim
    W. J. Yoo
    Clinical Neuroradiology, 2015, 25 : 379 - 386