Improvement of part load efficiency of a combined cycle power plant provisioning ancillary services

被引:51
作者
Variny, Miroslav [1 ]
Mierka, Otto [1 ]
机构
[1] Slovak Tech Univ Bratislava, Dept Chem & Biochem Engn, Bratislava 81237, Slovakia
关键词
Combined cycle; Part load performance; Ancillary services; Electric efficiency; Fuel savings; GAS-TURBINE; GENERATION SYSTEM; ENERGY;
D O I
10.1016/j.apenergy.2008.11.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
According to the type of ancillary service provisioned, operation mode of a power plant may change to part load operation. In this contribution, part load operation is understood as delivering a lower power output than possible at given ambient temperature because of gas turbine power output control. If it is economically justified, a power plant may operate in the part load mode for longer time. Part load performance of a newly built 80 MW combined cycle in Slovakia was studied in order to assess the possibilities for fuel savings. Based on online monitoring data three possibilities were identified: condensate preheating by activation of the currently idle hot water section; change in steam condensing pressure regulation strategy; and the most important gas turbine inlet air preheating. It may seem to be in contradiction with the well proven concept of gas turbine inlet air cooling, which has however been developed for boosting the gas turbine cycles in full load operation. On the contrary, in a combined cycle in the part load operation mode, elevated inlet air temperature does not affect the part load operation of gas turbines but it causes more high pressure steam to be raised in HRSG, which leads to higher steam turbine power output. As a result, less fuel needs to be combusted in gas turbines in order to achieve the requested combined cycle's power output. By simultaneous application of all three proposals, more than a 2% decrease in the power plant's natural gas consumption can be achieved with only minor capital expenses needed. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:888 / 894
页数:7
相关论文
共 15 条
[1]  
Abedin A., 1998, P INT C EN RES DEV K, V1, P390
[2]   Comparison of evaporative inlet air cooling systems to enhance the gas turbine generated power [J].
Ameri, Mohammad ;
Shahbazian, H. R. ;
Nabizadeh, M. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (15) :1483-1503
[3]   Comparison between two gas turbine solutions to increase combined power plant efficiency [J].
Carcasci, C ;
Facchini, B .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (08) :757-773
[4]   Performance effects of combined cycle power plant with variable condenser pressure and loading [J].
Chuang, CC ;
Sue, DC .
ENERGY, 2005, 30 (10) :1793-1801
[5]  
KARAKAS E, 2004, ENERGY, V29, P2347
[6]  
KIM JS, 1995, KOREAN J GASTROINTES, V15, P91
[7]   Power augmentation of combined cycle power plants using cold energy of liquefied natural gas [J].
Kim, TS ;
Ro, ST .
ENERGY, 2000, 25 (09) :841-856
[8]   The Nordic approach to market-based provision of ancillary services [J].
Kristiansen, Tarjei .
ENERGY POLICY, 2007, 35 (07) :3681-3700
[9]   Analysis of a repowering proposal to the power generation system of a steel mill plant through the exergetic cost method [J].
Modesto, M. ;
Nebra, S. A. .
ENERGY, 2006, 31 (15) :3261-3277
[10]   Technical and economic aspects of ancillary services markets in the electric power industry:: an international comparison [J].
Raineri, R ;
Ríos, S ;
Schiele, D .
ENERGY POLICY, 2006, 34 (13) :1540-1555