Methodology for adaptive and robust FDG-PET escalated dose painting by numbers in head and neck tumors

被引:29
作者
Differding, Sarah [1 ,2 ]
Sterpin, Edmond [1 ,2 ]
Janssens, Guillaume [1 ,2 ]
Hanin, Francois-Xavier [3 ,4 ]
Lee, John Aldo [1 ,2 ]
Gregoire, Vincent [1 ,2 ]
机构
[1] Catholic Univ Louvain, Inst Rech Expt & Clin, Dept Radiat Oncol, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, Inst Rech Expt & Clin, Ctr Mol Imaging Oncol & Radiotherapy MIRO, B-1200 Brussels, Belgium
[3] Catholic Univ Louvain, Inst Rech Expt & Clin, St Luc Univ Hosp, Dept Nucl Med, B-1200 Brussels, Belgium
[4] Catholic Univ Louvain, Inst Rech Expt & Clin, St Luc Univ Hosp, Ctr Mol Imaging Oncol & Radiotherapy MIRO, B-1200 Brussels, Belgium
关键词
INTENSITY-MODULATED RADIOTHERAPY; RADIATION-THERAPY; HELICAL TOMOTHERAPY; POSITRON-EMISSION; TARGET VOLUME; CANCER; FEASIBILITY; TRIAL; IMRT; UNCERTAINTIES;
D O I
10.3109/0284186X.2015.1046997
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective. To develop a methodology for using FDG PET/CT in adaptive dose painting by numbers (DPBN) in head and neck squamous cell carcinoma (HNSCC) patients. Issues related to noise in PET and treatment robustness against geometric errors are addressed. Methods. Five patients with locally advanced HNSCC scheduled for chemo-radiotherapy were imaged with FDG-PET/CT at baseline and 2-3 times during radiotherapy (RT). The GTV(PET) was segmented with a gradient-based method. A double median filter reduces the impact of noise in the PET uptake-to-dose conversion. Filtered FDG uptake values were linearly converted into a voxel-by-voxel prescription from 70 (median uptake) to 86 Gy (highest uptake). A PTVPET was obtained by applying a dilation of 2.5 mm to the entire prescription. Seven iso-uptake thresholds led to seven sub-levels compatible with the Tomotherapy HiArt((R)) Treatment Planning System. Planning aimed to deliver a median dose of 56 Gy and 70 Gy in 35 fractions on the elective and therapeutic PTVs, respectively. Plan quality was assessed with quality volume histogram (QVH). At each time point, plans were generated with a total of 3-4 plans for each patient. Deformable image registration was used for automatic contour propagation and dose summation of the 3 or 4 treatment plans (MIMvista((R))). Results. GTV(PET) segmentations were performed successfully until week 2 of RT but failed in two patients at week 3. QVH analysis showed high conformity for all plans (mean V-Q = 0.95 93%; mean V-Q = 1.05 3.9%; mean QF 2.2%). Good OAR sparing was achieved while keeping high plan quality. Conclusion. Our results show that adaptive FDG-PET-based escalated dose painting in patients with locally advanced HNSCC is feasible while respecting strict dose constraints to organs at risk. Clinical studies must be conducted to evaluate toxicities and tumor response of such a strategy.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 34 条
[1]   Stability of 18F-deoxyglucose uptake locations within tumor during radiotherapy for NSCLC:: A prospective study [J].
Aerts, Hugo J. W. L. ;
Bosmans, Geert ;
van Baardwijk, Angela A. W. ;
Dekker, Andre L. A. J. ;
Oellers, Michel C. ;
Lambin, Philippe ;
De Ruysscher, Dirk .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (05) :1402-1407
[2]   FDG for dose painting: A rational choice [J].
Aerts, Hugo J. W. L. ;
Lambin, Philippe ;
De Ruysscher, Dirk .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (02) :163-164
[3]   On biologically conformal boost dose optimization [J].
Alber, M ;
Paulsen, F ;
Eschmann, SM ;
Machulla, HJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (02) :N31-N35
[4]   Multi-modality functional image guided dose escalation in the presence of uncertainties [J].
Alber, Markus ;
Thorwarth, Daniela .
RADIOTHERAPY AND ONCOLOGY, 2014, 111 (03) :354-359
[5]  
[Anonymous], 2010, J ICRU
[6]   DOES MEDIAN FILTERING TRULY PRESERVE EDGES BETTER THAN LINEAR FILTERING? [J].
Arias-Castro, Ery ;
Donoho, David L. .
ANNALS OF STATISTICS, 2009, 37 (03) :1172-1206
[7]   Theragnostic imaging for radiation oncology: dose-painting by numbers [J].
Bentzen, SM .
LANCET ONCOLOGY, 2005, 6 (02) :112-117
[8]   Molecular Imaging-Based Dose Painting: A Novel Paradigm for Radiation Therapy Prescription [J].
Bentzen, Soren M. ;
Gregoire, Vincent .
SEMINARS IN RADIATION ONCOLOGY, 2011, 21 (02) :101-110
[9]   Three-phase adaptive dose-painting-by-numbers for head-and-neck cancer: initial results of the phase I clinical trial [J].
Berwouts, Dieter ;
Olteanu, Luiza A. M. ;
Duprez, Frederic ;
Vercauteren, Tom ;
De Gersem, Werner ;
De Neve, Wilfried ;
Van de Wiele, Christophe ;
Madani, Indira .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) :310-316
[10]   Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy:: An evaluation of the setup verification process for the special case of a rigid head phantom [J].
Boswell, Sarah ;
Tome, Wolfgang ;
Jeraj, Robert ;
Jaradat, Hazirn ;
Mackie, T. Rock .
MEDICAL PHYSICS, 2006, 33 (11) :4395-4404