Online Fault Diagnosis for Open-Cathode PEMFC Systems Based on Output Voltage Measurements and Data-Driven Method

被引:19
作者
Ma, Rui [1 ]
Dang, Hanbin [1 ]
Xie, Renyou [1 ]
Xu, Liangcai [1 ]
Zhao, Dongdong [1 ]
机构
[1] Northwestern Polytech Univ, Sch Automat, Xian 710072, Peoples R China
基金
中国国家自然科学基金;
关键词
Fault diagnosis; Feature extraction; Fuel cells; Hydrogen; Transportation; Analytical models; Water heating; Classification; data-driven fault diagnosis; fault degree; open-cathode proton exchange membrane fuel cell (PEMFC) system; MODEL-BASED DIAGNOSIS; FUEL-CELL SYSTEMS; TOLERANT CONTROL; MANAGEMENT; METHODOLOGIES; STACKS;
D O I
10.1109/TTE.2021.3114194
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fault diagnosis is essential for the stable and efficient operation of the proton exchange membrane fuel cell (PEMFC) system. However, the manifold balance of plant (BOP) components and the coupling phenomenon involving multiple physical fields will significantly increase the probability of system fault, which makes it difficult to realize a timely and effective diagnosis. In this study, a novel online diagnosis method for an open-cathode PEMFC system is proposed, which is only based on output voltage measurements, and both the normal state and fault states caused by abnormal BOP components operation are taken into consideration. Specifically, the fault identification is realized based on the fusion of t-Distributed Stochastic Neighbor Embedding (t-SNE) and eXtreme Gradient Boosting (XGBoost), where the t-SNE is adopted to extract the diagnostic features from the individual cell output voltages and the XGBoost is adopted to identify the fault type based on the extracted diagnostic features. A facile method based on the gray relational analysis (GRA) is also proposed to quantify the fault degree, which can contribute to the condition-based maintenance of the system. The results validated by the fuel cell system diagnostic experiments reveal that the novel method can effectively identify the five health states and the fault degree. The overall accuracy is 99.31%, and the diagnosis period is shortened from 0.3375 to 0.1416 s after processing by t-SNE, which indicates that the proposed method can have a better performance compared with the traditional methods.
引用
收藏
页码:2050 / 2061
页数:12
相关论文
共 46 条
  • [1] A human liver cell atlas reveals heterogeneity and epithelial progenitors
    Aizarani, Nadim
    Saviano, Antonio
    Sagar
    Mailly, Laurent
    Durand, Sarah
    Herman, Josip S.
    Pessaux, Patrick
    Baumert, Thomas F.
    Gruen, Dominic
    [J]. NATURE, 2019, 572 (7768) : 199 - 204
  • [2] Investigation of effects of high temperature and pressure on a polymer electrolyte fuel cell with polarization analysis and X-ray imaging of liquid water
    Akitomo, Fumiya
    Sasabe, Takashi
    Yoshida, Toshihiko
    Naito, Hiroshi
    Kawamura, Katsuyuki
    Hirai, Shuichiro
    [J]. JOURNAL OF POWER SOURCES, 2019, 431 : 205 - 209
  • [3] [Anonymous], 2002, ADV NEURAL INFORM PR
  • [4] Diagnosis of PEM fuel cell stack dynamic behaviors
    Chen, Jixin
    Zhou, Biao
    [J]. JOURNAL OF POWER SOURCES, 2008, 177 (01) : 83 - 95
  • [5] XGBoost: A Scalable Tree Boosting System
    Chen, Tianqi
    Guestrin, Carlos
    [J]. KDD'16: PROCEEDINGS OF THE 22ND ACM SIGKDD INTERNATIONAL CONFERENCE ON KNOWLEDGE DISCOVERY AND DATA MINING, 2016, : 785 - 794
  • [6] A review of fault tolerant control strategies applied to proton exchange membrane fuel cell systems
    Dijoux, Etienne
    Steiner, Nadia Yousfi
    Benne, Michel
    Pera, Marie-Cecile
    Perez, Brigitte Grondin
    [J]. JOURNAL OF POWER SOURCES, 2017, 359 : 119 - 133
  • [7] Data-based flooding fault diagnosis of proton exchange membrane fuel cell systems using LSTM networks
    Gu, Xin
    Hou, Zhongjun
    Cai, Jun
    [J]. ENERGY AND AI, 2021, 4
  • [8] Diagnostic & health management of fuel cell systems: Issues and solutions
    Hissel, D.
    Pera, M. C.
    [J]. ANNUAL REVIEWS IN CONTROL, 2016, 42 : 201 - 211
  • [9] A Novel Power Transformer Condition Monitoring System Based on Wide-Band Measurement of Core Earth Signals and Correlation Analysis With Multi-Source Data
    Ke, Xuezhi
    Pang, Lisheng
    Dong, Xiang
    Li, Zhaohui
    [J]. IEEE ACCESS, 2019, 7 : 161754 - 161763
  • [10] Implementation of discrete wavelet transform-based discrimination and state-of-health diagnosis for a polymer electrolyte membrane fuel cell
    Kim, Jonghoon
    Tak, Yongsug
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (20) : 10664 - 10682