Detection of In Vivo Dynamic 3-D Motion Patterns in the Wrist Joint

被引:25
作者
Carelsen, Bart [1 ]
Jonges, Remmet [1 ]
Strackee, Simon D. [2 ]
Maas, Mario [3 ]
van Kemenade, Patricia [4 ]
Grimbergen, Cornelis A. [1 ]
van Herk, Marcel [1 ]
Streekstra, Geert J. [1 ]
机构
[1] Acad Med Ctr, Dept Med Phys, NL-1100 DD Amsterdam, Netherlands
[2] Acad Med Ctr, Dept Plast Reconstruct & Hand Surg, NL-1100 DD Amsterdam, Netherlands
[3] Acad Med Ctr, Dept Radiol, NL-1100 DD Amsterdam, Netherlands
[4] Philips Healthcare, NL-5600 PB Eindhoven, Netherlands
关键词
Dynamic imaging; joint imaging; skeletal; X-ray; CARPAL KINEMATICS; REGISTRATION;
D O I
10.1109/TBME.2008.2009069
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a method for measurement dynamic in vivo carpal motion patterns. The method consists of a 4-D rotational X-ray (RX) with improved image quality and image processing for accurate detection in vivo wrist motion measurements. Dynamic 3-D imaging yields a number of volume reconstructions of the wrist at different phases of its cyclic motion. Next, the carpal reconstructions are registered to their static acquired and segmented counterpart in all phases. With this information, the relation between the applied motion and carpal kinematic behavior is acquired, i.e., the motion patterns. We investigated the precision of the image acquisition and processing and tested it on three healthy subjects. The precision of the image acquisition and image processing is in the range of submillimeters and subdegrees, respectively, which is better than existing systems and sufficient for clinical investigations. Reproducibility measurements show some more deviation (>1 degrees). This method was tested on four human volunteers and agrees for the greater part with previously done invasive and nondynamic measurements. In vivo motion pattern measurement with 4-D-RX imaging and processing is accurate and noninvasive. The motion patterns can reveal disorders that could not have been detected in either video fluoroscopy, computed tomography, or MRI.
引用
收藏
页码:1236 / 1244
页数:9
相关论文
共 32 条
  • [1] Diagnostic comparison of 1.5 Tesla and 3.0 Tesla preoperative MRI of the wrist in patients with ulnar-sided wrist pain
    Anderson, Meredith L.
    Skinner, John A.
    Felmlee, Joel P.
    Berger, Richard A.
    Amrami, Kimberly K.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (07): : 1153 - 1159
  • [2] [Anonymous], 1992, J GEOM ANAL, DOI DOI 10.1007/BF02921333
  • [3] The hysteresis effect in carpal kinematics
    Berdia, S
    Short, WH
    Werner, FW
    Green, JK
    Panjabi, M
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (04): : 594 - 600
  • [4] BOND JR, 1991, HAND CLIN, V7, P113
  • [5] Brakke K.A., 1992, Exper. Math, V1, P141, DOI DOI 10.1080/10586458.1992.10504253
  • [6] Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    [J]. MEDICAL PHYSICS, 2003, 30 (09) : 2323 - 2331
  • [7] 4D rotational x-ray imaging of wrist joint dynamic motion
    Carelsen, B
    Bakker, NH
    Strackee, SD
    Boon, SN
    Maas, M
    Sabczynski, J
    Grimbergen, CA
    Streekstra, GJ
    [J]. MEDICAL PHYSICS, 2005, 32 (09) : 2771 - 2776
  • [8] CASTLEMAN KR, 1996, DIGITAL IMAGE PROCES, P473
  • [9] Crisco TJ, 1999, J ORTHOP RES, V17, P96
  • [10] Imaging of four-corner fusion (SLAC arthrodesis) of the wrist with 64-slice computed tomography
    Ekelund, L.
    Hagberg, L.
    Horberg, L.
    Jorgsholm, P.
    Gunnarsson, M.
    [J]. ACTA RADIOLOGICA, 2007, 48 (01) : 76 - 79