Anthropomorphic breast phantoms for testing elastography systems

被引:82
作者
Madsen, Ernest L.
Hobson, Maritza A.
Frank, Gary R.
Shi, Hairong
Jiang, Jingfeng
Hall, Timothy J.
Varghese, Tomy
Doyley, Marvin M.
Weaver, John B.
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Radiol, Lebanon, NH 03766 USA
关键词
elastography; elasticity; phantom; breast; ultrasound; MR;
D O I
10.1016/j.ultrasmedbio.2006.02.1428
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Two equivalent anthropomorphic breast phantoms were constructed, one for use in ultrasound elastography and the other in magnetic resonance (MR) elastography. A complete description of the manufacturing methods is provided. The materials used were oil-in-gelatin dispersions, where the volume percent oil differentiates the materials, primarily according to Young's moduli. Values of Young's moduli are in agreement with in vitro ranges for the corresponding normal and abnormal breast tissues. Ultrasound and nuclear magnetic resonance (NMR) properties are reasonably well represented. Phantoms of the type described promise to aid researchers who are developing hardware and software for elastography. Examples of ultrasound and MR elastograms of the phantoms are included to demonstrate the utility of the phantoms. Also, the level of stability of elastic properties of the component materials is quantified over a 15-month period. Such phantoms can serve as performance-assessing intermediaries between simple phantoms (consisting, for example, of homogeneous cylindrical inclusions in a homogeneous background) and a full-scale clinical trial. Thus, premature clinical trials may be avoided. (E-mail: elmadsen@wisc.edu) (c) 2006 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:857 / 874
页数:18
相关论文
共 37 条
[1]   Finite element modeling and intravascular ultrasound elastography of vulnerable plaques: parameter variation [J].
Baldewsing, RA ;
de Korte, CL ;
Schaar, JA ;
Mastik, F ;
van der Steen, AFW .
ULTRASONICS, 2004, 42 (1-9) :723-729
[2]   A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries [J].
Baldewsing, RA ;
De Korte, CL ;
Schaar, JA ;
Mastik, F ;
Van Der Steen, AFW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (06) :803-813
[3]  
BEVINGTON PR, 1969, DATA REDUCTION ERROR, P106
[4]   TISSUE-MIMICKING GELATIN AGAR GELS FOR USE IN MAGNETIC-RESONANCE IMAGING PHANTOMS [J].
BLECHINGER, JC ;
MADSEN, EL ;
FRANK, GR .
MEDICAL PHYSICS, 1988, 15 (04) :629-636
[5]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[6]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[7]   Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity [J].
Chu, KC ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :314-319
[8]   FREQUENCY-DEPENDENCE OF ULTRASOUND ATTENUATION AND BACKSCATTER IN BREAST-TISSUE [J].
DASTOUS, FT ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (10) :795-808
[9]   SONOELASTICITY IMAGING - THEORY AND EXPERIMENTAL-VERIFICATION [J].
GAO, L ;
PARKER, KJ ;
ALAM, SK ;
LERNER, RM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (06) :3875-3886
[10]   In vivo real-time freehand palpation imaging [J].
Hall, TJ ;
Zhu, YN ;
Spalding, CS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03) :427-435