Reproducibility of the external surface position in left-breast DIBH radiotherapy with spirometer-based monitoring

被引:25
作者
Fassi, Aurora [1 ]
Ivaldi, Giovanni B. [2 ]
Meaglia, Ilaria [2 ]
Porcu, Patrizia [2 ]
de Fatis, Paola Tabarelli [3 ]
Liotta, Marco [3 ]
Riboldi, Marco [1 ,4 ]
Baroni, Guido [1 ,4 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] Fdn Salvatore Maugeri, Dept Radiat Oncol, Pavia, Italy
[3] Fdn Salvatore Maugeri, Pavia, Italy
[4] CNAO Fdn, Bioengn Unit, Pavia, Italy
关键词
left-breast cancer; DIBH radiotherapy; spirometric monitoring; optical tracking; surface reproducibility; ACTIVE BREATHING CONTROL; HOLD TECHNIQUE; RESPIRATORY MOTION; CANCER PATIENTS; TARGET; LUNG; HEART; IMMOBILIZATION; TRACKING; GUIDANCE;
D O I
10.1120/jacmp.v15i1.4494
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deep inspiration breath hold (DIBH) in left-sided breast cancer radiotherapy treatments allows for a reduction in cardiac and pulmonary doses without compromising target coverage. The selection of the most appropriate technology for DIBH monitoring is a crucial issue. We evaluated the stability and reproducibility of DIBHs controlled by a spirometric device, by assessing the variability of the external surface position within a single DIBH (intra-DIBH) and between DIBHs performed in the same treatment session (intrafraction) or in different sessions (interfraction). The study included seven left-breast cancer patients treated with spirometer-based DIBH radiotherapy. Infrared optical tracking was used to record the 3D coordinates of seven to eleven passive markers placed on the patient's thoraco-abdominal surface during 29-43 DIBHs performed in six to eight treatment sessions. The obtained results showed displacements of the external surface between different sessions up to 6.3 mm along a single direction, even at constant inspired volumes. The median value of the interfraction variability in the position of breast passive markers was 2.9 mm (range 1.9-4.8 mm) in the latero-lateral direction, 3.6 mm (range 2.2-4.6 mm) in the antero-posterior direction, and 4.3 mm (range 2.8-6.2 mm) in the cranio-caudal direction. There were no significant dose distribution variations for target and organs at risk with respect to the treatment plan, confirming the adequacy of the applied clinical margins (15 mm) to compensate for the measured setup uncertainties. This study demonstrates that spirometer-based control does not guarantee a stable and reproducible position of the external surface in left-breast DIBH radiotherapy, suggesting the need for more robust DIBH monitoring techniques when reduced margins and setup uncertainties are required for improving normal tissue sparing and decreasing cardiac and pulmonary toxicity.
引用
收藏
页码:130 / 140
页数:11
相关论文
共 29 条
[1]  
Abdel-Aziz YI, 1971, P S CLOS RANG PHOT S, V1, P1
[2]  
Abe O, 2005, LANCET, V366, P2087, DOI 10.1016/s0140-6736(05)66544-0
[3]   Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy [J].
Alderliesten, Tanja ;
Sonke, Jan-Jakob ;
Betgen, Anja ;
Honnef, Joeri ;
van Vliet-Vroegindeweij, Corine ;
Remeijer, Peter .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02) :536-542
[4]   Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography [J].
Aliverti, A ;
Dellacà, R ;
Pelosi, P ;
Chiumello, D ;
Gattinoni, L ;
Pedotti, A .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (01) :60-70
[5]   Dosimetric effects within target and organs at risk of interfractional patient mispositioning in left breast cancer radiotherapy [J].
Baroni, G ;
Garibaldi, C ;
Scabini, M ;
Riboldi, M ;
Catalano, G ;
Tosi, G ;
Orecchia, R ;
Pedotti, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03) :861-871
[6]   Integration of enhanced optical tracking techniques and imaging in IGRT [J].
Baroni, Guido ;
Riboldi, Marco ;
Spadea, Maria Francesca ;
Tagaste, Barbara ;
Garibaldi, Cristina ;
Orecchia, Roberto ;
Pedotti, Antonio .
JOURNAL OF RADIATION RESEARCH, 2007, 48 :A61-A74
[7]   Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging [J].
Betgen, Anja ;
Alderliesten, Tanja ;
Sonke, Jan-Jakob ;
van Vliet-Vroegindeweij, Corine ;
Bartelink, Harry ;
Remeijer, Peter .
RADIOTHERAPY AND ONCOLOGY, 2013, 106 (02) :225-230
[8]   Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapy [J].
Cervino, Laura I. ;
Gupta, Sonia ;
Rose, Mary A. ;
Yashar, Catheryn ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22) :6853-6865
[9]   Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer [J].
Djajaputra, D ;
Li, SD .
MEDICAL PHYSICS, 2005, 32 (01) :65-75
[10]   A Voluntary Breath-Hold Treatment Technique for the Left Breast With Unfavorable Cardiac Anatomy Using Surface Imaging [J].
Gierga, David P. ;
Turcotte, Julie C. ;
Sharp, Gregory C. ;
Sedlacek, Daniel E. ;
Cotter, Christopher R. ;
Taghian, Alphonse G. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (05) :E663-E668