Transmission-less attenuation correction in time-of-flight PET: analysis of a discrete iterative algorithm

被引:39
作者
Defrise, Michel [1 ]
Rezaei, Ahmadreza [2 ]
Nuyts, Johan [2 ]
机构
[1] Vrije Univ Brussel, Dept Nucl Med, B-1090 Brussels, Belgium
[2] Katholieke Univ Leuven, Dept Nucl Med, B-3000 Louvain, Belgium
关键词
image reconstruction; positron tomography; attenuation correction; EMISSION; RECONSTRUCTION; PERFORMANCE; IMAGES;
D O I
10.1088/0031-9155/59/4/1073
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The maximum likelihood attenuation correction factors (MLACF) algorithm has been developed to calculate the maximum-likelihood estimate of the activity image and the attenuation sinogram in time-of-flight (TOF) positron emission tomography, using only emission data without prior information on the attenuation. We consider the case of a Poisson model of the data, in the absence of scatter or random background. In this case the maximization with respect to the attenuation factors can be achieved in a closed form and the MLACF algorithm works by updating the activity. Despite promising numerical results, the convergence of this algorithm has not been analysed. In this paper we derive the algorithm and demonstrate that the MLACF algorithm monotonically increases the likelihood, is asymptotically regular, and that the limit points of the iteration are stationary points of the likelihood. Because the problem is not convex, however, the limit points might be saddle points or local maxima. To obtain some empirical insight into the latter question, we present data obtained by applying MLACF to 2D simulated TOF data, using a large number of iterations and different initializations.
引用
收藏
页码:1073 / 1095
页数:23
相关论文
共 41 条
[1]  
Ahn S, 2012, IEEE NUCL SCI CONF R, P3695
[2]  
[Anonymous], 2005, Positron Emission Tomography: Basic Sciences, DOI DOI 10.1007/1-84628-007-9_5
[3]  
Bai CY, 2003, J NUCL MED, V44, P1855
[4]   Physical Performance of the new hybrid PET/CT Discovery-690 [J].
Bettinardi, V. ;
Presotto, L. ;
Rapisarda, E. ;
Picchio, M. ;
Gianolli, L. ;
Gilardi, M. C. .
MEDICAL PHYSICS, 2011, 38 (10) :5394-5411
[5]   Reconstruction of attenuation map using discrete consistency conditions [J].
Bronnikov, AV .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) :451-462
[6]  
Carney J, 2003, IEEE NUCL SCI CONF R, P1443
[7]   NEW APPROACH TO THE EMISSION COMPUTERIZED TOMOGRAPHY PROBLEM - SIMULTANEOUS CALCULATION OF ATTENUATION AND ACTIVITY-COEFFICIENTS [J].
CENSOR, Y ;
GUSTAFSON, DE ;
LENT, A ;
TUY, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2775-2779
[8]   Exact and approximate Fourier rebinning of PET data from time-of-flight to non time-of-flight [J].
Cho, Sanghee ;
Ahn, Sangtae ;
Li, Quanzheng ;
Leahy, Richard M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (03) :467-484
[9]  
CLINTHORNE NH, 1991, CONFERENCE RECORD OF THE 1991 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE, VOLS 1-3, P1927, DOI 10.1109/NSSMIC.1991.259253
[10]   Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? [J].
Conti, Maurizio .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01) :155-168