Measurement of the energy distribution of parametric X-ray radiation from a double-crystal system

被引:6
作者
Mori, Akira [1 ]
Hayakawa, Yasushi
Kidokoro, Akio
Sato, Isamu
Tanaka, Toshinari
Hayakawa, Ken
Kobayashi, Kouji
Ohshima, Hisashi
机构
[1] Nihon Univ, Coll Pharm, Funabashi, Chiba 2748555, Japan
[2] Nihon Univ, Lab Electron Beam Res & Applicat, Funabashi, Chiba 2748501, Japan
关键词
parametric X-ray radiation; energy distribution; linear gradation;
D O I
10.1016/j.nimb.2006.08.013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A parametric X-ray radiation (PXR) generator system was developed at the Laboratory for Electron Beam Research and Applications (LEBRA) at Nihon University; this PXR generator system is a tunable wavelength and quasi-monochromatic X-ray source constructed as one of the advanced applications of the LEBRA 125-MeV electron linear accelerator. The PXR beam which has characteristic of energy distribution. The theoretical values of energy distribution obtained at the output port were calculated to be approximately 300 eV and 2 keV at the central X-ray energies of 7 keV and 20 keV, respectively. In order to investigate the energy distribution, several measurements of the X-ray energy were carried out. The X-ray absorption of known materials and that of thin aluminum has been evaluated based on analyses of images taken using an imaging plate. The X-ray energy was deduced base oh the identification of the absorption edges, and the energy distribution was estimated based on measurements using aluminum step method. In addition, an X-ray diffraction method using a perfect silicon crystal was employed, and spectra were measured using a solid state detector (SSD). The results of these experiments agreed with the calculated results. In particular, the well-defined absorption edges in the X-ray images and the typical rocking curves obtained by the measurement of the X-ray diffraction indicated that the distribution has a high-energy resolution. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 15 条
[1]   MEASUREMENT OF SPECTRAL AND POLARIZATION CHARACTERISTICS OF PARAMETRIC X-RAYS IN A SI CRYSTAL [J].
ADISHCHEV, YN ;
VERZILOV, VA ;
POTYLITSYN, AP ;
UGLOV, SR ;
VOROBYEV, SA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 44 (02) :130-136
[3]   How narrow is the linewidth of parametric x-ray radiation? [J].
Brenzinger, KH ;
Limburg, B ;
Backe, H ;
Dambach, S ;
Euteneuer, H ;
Hagenbuck, F ;
Herberg, C ;
Kaiser, KH ;
Kettig, O ;
Kube, G ;
Lauth, W ;
Schope, H ;
Walcher, T .
PHYSICAL REVIEW LETTERS, 1997, 79 (13) :2462-2465
[4]   PARAMETRIC X-RADIATION FROM THICK CRYSTALS [J].
ENDO, I ;
HARADA, M ;
KOBAYASHI, T ;
LEE, YS ;
OHGAKI, T ;
TAKAHASHI, T ;
MUTO, M ;
YOSHIDA, K ;
NITTA, H ;
OHBA, T .
PHYSICAL REVIEW E, 1995, 51 (06) :6305-6308
[5]   OBSERVATION OF HIGHER-ORDER PARAMETRIC X-RAY-SPECTRA IN MOSAIC GRAPHITE AND SINGLE SILICON-CRYSTALS [J].
FIORITO, RB ;
RULE, DW ;
MARUYAMA, XK ;
DINOVA, KL ;
EVERTSON, SJ ;
OSBORNE, MJ ;
SNYDER, D ;
RIETDYK, H ;
PIESTRUP, MA ;
HO, AH .
PHYSICAL REVIEW LETTERS, 1993, 71 (05) :704-707
[6]   Parametric X rays observed under Bragg condition: Boost of intensity by a factor of two [J].
Freudenberger, J ;
Genz, H ;
Morokhovskyi, VV ;
Richter, A ;
Sellschop, JPF .
PHYSICAL REVIEW LETTERS, 2000, 84 (02) :270-273
[7]   Simulations to the project of a PXR based X-ray source composed of an electron linac and a double-crystal system [J].
Hayakawa, Y ;
Sato, I ;
Hayakawa, K ;
Tanaka, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 227 (1-2) :32-40
[8]   First lasing of LEBRA FEL at Nihon University at a wavelength of 1.5 μm [J].
Hayakawa, Y ;
Sato, I ;
Hayakawa, K ;
Tanaka, T ;
Nakazawa, H ;
Yokoyama, K ;
Kanno, K ;
Sakai, T ;
Ishiwata, K ;
Enomoto, A ;
Fukuda, S ;
Ohsawa, S ;
Tsuchiya, K ;
Kato, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2) :29-33
[9]   Analysis of the angular distribution and the intensity of parametric X-ray radiation in a Bragg case [J].
Hayakawa, Y ;
Seto, M ;
Maeda, Y ;
Shirai, T ;
Noda, A .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1998, 67 (03) :1044-1049
[10]  
HAYAKAWA Y, 2001, P 26 LIN ACC M JAP T, P110