Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [41] Detection of changes in the locus coeruleus in patients with mild cognitive impairment and Alzheimer's disease: High-resolution fast spin-echo T1-weighted imaging
    Takahashi, Junko
    Shibata, Toshihide
    Sasaki, Makoto
    Kudo, Masako
    Yanezawa, Hisashi
    Obara, Satoko
    Kudo, Kohsuke
    Ito, Kenji
    Yamashita, Fumio
    Terayama, Yasuo
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2015, 15 (03) : 334 - 340
  • [42] Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences
    Fischbach, F
    Bruhn, H
    Unterhauser, F
    Ricke, J
    Wieners, G
    Felix, R
    Weiler, A
    Schröder, RJ
    ACTA RADIOLOGICA, 2005, 46 (01) : 67 - 73
  • [43] Fast Spin-Echo Triple-Echo Dixon: Initial Clinical Experience With A Novel Pulse Sequence for Fat-Suppressed T2-Weighted Abdominal MR Imaging
    Low, Russell N.
    Ma, Jingfei
    Panchal, Neeraj
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 569 - 577
  • [44] Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance Imaging of the brain: An alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?
    Alibek, Sedat
    Adamietz, Boris
    Cavallaro, Alexander
    Stemmer, Alto
    Anders, Katharina
    Kramer, Manuel
    Bautz, Werner
    Staatz, Gundula
    ACADEMIC RADIOLOGY, 2008, 15 (08) : 986 - 995
  • [45] Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T
    Sarlls, Joelle E.
    Pierpaoli, Carlo
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (02) : 270 - 276
  • [46] Liver T2-weighted MR imaging: Assessment of a three-dimensional fast spin-echo with extended echo train acquisition sequence at 1.5 Tesla
    Denoiseux, Celine Cotereau
    Boulay-Coletta, Isabelle
    Nakache, Jean-Pierre
    Claude, Isabelle Dufour
    Zins, Marc
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 336 - 343
  • [47] Readout-segmented Echo-planar Imaging for Diffusion-weighted Imaging in the Pelvis at 3T-A Feasibility Study
    Thian, Yee Liang
    Xie, Wanying
    Porter, David A.
    Ang, Bertrand Weileng
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 531 - 537
  • [48] Post-gadolinium evaluation of intracranial tumours: a comparative study of Spin Echo, Fast Spin Echo, Gradient Echo T1-weighted sequences, with and without Magnetization Transfer
    Aprile, I
    Lavaroni, A
    Scott, CA
    Budai, R
    Beltrami, CA
    Fabris, G
    RIVISTA DI NEURORADIOLOGIA, 2001, 14 (03): : 259 - 265
  • [49] MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN
    BRANTZAWADZKI, M
    GILLAN, GD
    NITZ, WR
    RADIOLOGY, 1992, 182 (03) : 769 - 775
  • [50] Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    van Smoorenburg, Luuk
    Schwenk, Arpad
    Mannil, Manoj
    Graf, Nicole
    Binkert, Christoph A.
    Wyss, Michael
    Sartoretti-Schefer, Sabine
    INVESTIGATIVE RADIOLOGY, 2020, 55 (12) : 775 - 784