Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [31] Contrast-enhanced multi-shot echo-planar FLAIR in the depiction of metastatic tumors of the brain: Comparison with contrast-enhanced spin-echo T1-weighted Imaging
    Tomura, N.
    Narita, K.
    Takahashi, S.
    Otani, T.
    Sakuma, I.
    Yasuda, K.
    Nishii, T.
    Watarai, J.
    ACTA RADIOLOGICA, 2007, 48 (09) : 1032 - 1037
  • [32] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383
  • [33] Feasibility study of exploring a T1-weighted dynamic contrast-enhanced MR approach for brain perfusion imaging
    Zhang, Yudong
    Wang, Jing
    Wang, Xiaoying
    Zhang, Jue
    Fang, Jing
    Jiang, Xuexiang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (06) : 1322 - 1331
  • [34] MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T
    Crombe, A.
    Saranathan, M.
    Ruet, A.
    Durieux, M.
    de Roquefeuil, E.
    Ouallet, J. C.
    Brochet, B.
    Dousset, V.
    Tourdias, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 501 - 507
  • [35] MR EVALUATION OF VERTEBRAL METASTASES - T1-WEIGHTED, SHORT-INVERSION-TIME INVERSION-RECOVERY, FAST SPIN-ECHO, AND INVERSION-RECOVERY FAST SPIN-ECHO SEQUENCES
    MEHTA, RC
    MARKS, MP
    HINKS, RS
    GLOVER, GH
    ENZMANN, DR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (02) : 281 - 288
  • [36] Analysis of magnetization transfer effects on T1-weighted spin-echo scans using a simple tissue phantom simulating gadolinium-enhanced brain lesions
    Finelli, DA
    Hurst, GC
    Frank, HA
    Gullapali, RP
    Apicella, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 731 - 738
  • [37] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [38] LUMBAR DEGENERATIVE DISK DISEASE - PROSPECTIVE COMPARISON OF CONVENTIONAL T2-WEIGHTED SPIN-ECHO IMAGING AND T2-WEIGHTED RAPID ACQUISITION RELAXATION-ENHANCED IMAGING
    ROSS, JS
    RUGGIERI, P
    TKACH, J
    OBUCHOWSKI, N
    DILLINGER, J
    MASARYK, TJ
    MODIC, MT
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (05) : 1215 - 1223
  • [39] T2 quantification in brain using 3D fast spin-echo imaging with long echo trains
    Snyder, Jeff
    McPhee, Kelly C.
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2145 - 2160
  • [40] MULTISLAB 3-DIMENSIONAL T2-WEIGHTED FAST SPIN-ECHO IMAGING OF THE HIPPOCAMPUS - SEQUENCE OPTIMIZATION
    MURAKAMI, JW
    WEINBERGER, E
    TSURUDA, JS
    MITCHELL, JD
    YUAN, C
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 309 - 315