Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [21] T1-weighted imaging of the brain at 3 tesla using a 2-dimensional spoiled gradient echo technique
    Runge, VM
    Patel, MC
    Baumann, SS
    Simonetta, AB
    Ponzo, JA
    Lesley, WS
    Calderwood, GW
    Naul, LG
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 68 - 75
  • [22] INTRACRANIAL LESION ENHANCEMENT WITH GADOLINIUM - T1-WEIGHTED SPIN-ECHO VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM GRADIENT-ECHO MR IMAGING
    MIROWITZ, SA
    RADIOLOGY, 1992, 185 (02) : 529 - 534
  • [23] THEORETICAL-ANALYSIS OF GADOPENTETATE DIMEGLUMINE ENHANCEMENT IN T1-WEIGHTED IMAGING OF THE BRAIN - COMPARISON OF 2-DIMENSIONAL SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO SEQUENCES
    MUGLER, JP
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 761 - 769
  • [24] Performance of Spin-Echo and Gradient-Echo T1-Weighted Sequences for Evaluation of Dural Venous Sinus Thrombosis and Stenosis
    Saindane, Amit M.
    Mitchell, Bradford C.
    Kang, Jian
    Desai, Nilesh K.
    Dehkharghani, Seena
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) : 162 - 169
  • [25] Magnetisation-prepared rapid gradient-echo versus inversion recovery turbo spin-echo T1-weighted images for segmentation of deep grey matter structures at 3 T
    Brandao, S.
    Bastos-Leite, A. J.
    CLINICAL RADIOLOGY, 2016, 71 (12) : 1304 - 1308
  • [26] Contrast-enhanced T1-weighted black-blood fast spin-echo MR imaging of the brain - Technique for suppression of enhancing venous signal
    Amano, Y
    Takagi, R
    Takahama, K
    Kumazaki, T
    ACTA RADIOLOGICA, 2001, 42 (01) : 27 - 32
  • [27] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [28] Contrast enhanced IR-SSFP examination compared with T1-weighted turbo spin-echo imaging of cardiac tumors and tumorlike lesions
    Bauner, K. U.
    Sandner, T.
    Notohamiprodjo, M.
    Schmoeckel, M.
    Reiser, M. F.
    Huber, A. M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (01) : 93 - 98
  • [29] Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence
    Yoon, Min A.
    Hong, Suk-Joo
    Lee, Kyu-Chong
    Lee, Chang Hee
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (01) : 46 - 50
  • [30] Gray - white matter contrast reversal on T 1-weighted spin-echo in postmortem brain
    Kojima, Masatoshi
    Makino, Yohsuke
    Yamaguchi, Rutsuko
    Motomura, Ayumi
    Yajima, Daisuke
    Inokuchi, Go
    Saito, Naoki
    Torimitsu, Suguru
    Hoshioka, Yumi
    Urabe, Shumari
    Yoshida, Maiko
    Iwase, Hirotaro
    Miyati, Tosiaki
    FORENSIC SCIENCE INTERNATIONAL, 2024, 360