Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [11] Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    Naganawa, Shinji
    Satake, Hiroko
    Iwano, Shingo
    Kawai, Hisashi
    Kubota, Seiji
    Komada, Tomohiro
    Kawamura, Minako
    Sakurai, Yasuo
    Fukatsu, Hiroshi
    EUROPEAN RADIOLOGY, 2008, 18 (02) : 337 - 342
  • [12] Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences
    Li, DB
    Haacke, EM
    Tarr, RW
    Venkatesan, R
    Lin, WL
    Wielopolski, P
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 415 - 424
  • [13] PATHOLOGY OF THE MEMBRANOUS LABYRINTH - COMPARISON OF T1-WEIGHTED AND T2-WEIGHTED AND GADOLINIUM-ENHANCED SPIN-ECHO AND 3DFT-CISS IMAGING
    CASSELMAN, JW
    KUHWEIDE, R
    AMPE, W
    MEEUS, L
    STEYAERT, L
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (01) : 59 - 69
  • [14] Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Yoshida, Atsushi
    Tha, Khin Khin
    Fujima, Noriyuki
    Zaitsu, Yuri
    Yoshida, Daisuke
    Tsukahara, Akiko
    Onodera, Shunsuke
    Shirato, Hiroki
    Terae, Satoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 84 - 90
  • [15] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182
  • [16] Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla
    Lavdas, Eleftherios
    Vlychou, Marianna
    Arikidis, Nikos
    Kapsalaki, Eftychia
    Roka, Violetta
    Fezoulidis, Ioannis V.
    ACTA RADIOLOGICA, 2010, 51 (03) : 290 - 295
  • [17] Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI
    Li, Zhaotong
    Cao, Gan
    Zhang, Li
    Yuan, Jichun
    Li, Sha
    Zhang, Zeru
    Wu, Fengliang
    Gao, Song
    Xia, Jun
    EUROPEAN RADIOLOGY, 2024, 34 (09) : 5783 - 5799
  • [18] Comparison of Spin-Echo T1-and T2-Weighted and Gradient-Echo T1-Weighted Images at 3T in Evaluating Very Preterm Neonates at Term-Equivalent Age
    Sarikaya, B.
    McKinney, A. M.
    Spilseth, B.
    Truwit, C. L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 1098 - 1103
  • [19] T1-weighted MR imaging of the brain using a fast inversion recovery pulse sequence
    Rydberg, JN
    Hammond, CA
    Huston, J
    Jack, CR
    Grimm, RC
    Riederer, SJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02): : 356 - 362
  • [20] Feasibility of brain age predictions from clinical T1-weighted MRIs
    Valdes-Hernandez, Pedro A.
    Nodarse, Chavier Laffitte
    Cole, James H.
    Cruz-Almeida, Yenisel
    BRAIN RESEARCH BULLETIN, 2023, 205