Spin-echo T1-weighted Imaging of the Brain with Interleaved Acquisition and Presaturation Pulse at 3 T: A Feasibility Study Before Clinical Use

被引:3
|
作者
Kasahara, Seiko [1 ]
Miki, Yukio [1 ]
Mori, Nobuyuki [1 ]
Urayama, Shin-ichi [2 ]
Kanagaki, Mitsunori [1 ]
Fushimi, Yasutaka [3 ]
Maeda, Chikara [1 ]
Sawamoto, Nobukatsu [2 ]
Fukuyama, Hidenao [2 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Dept Diagnost Imaging & Nucl Med, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Human Brain Res Ctr, Sakyo Ku, Kyoto 6068507, Japan
[3] Hikone Municipal Hosp, Dept Radiol, Shiga, Japan
关键词
Spin-echo sequence; T1-weighted image; brain; 3; T; ATTENUATED INVERSION-RECOVERY; WHITE MATTER CONTRAST; HIGH FIELD MRI; MAGNETIC-RESONANCE; MACROSCOPIC SUSCEPTIBILITY; ARTIFACTS; STRENGTH; IMAGES; TIME;
D O I
10.1016/j.acra.2008.12.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although spin-echo (SE) sequence has some advantages over gradient-echo sequence in brain imaging, gradient-echo sequence is commonly used For T1-weighted imaging (T1WI) at 3 T because contrast on SE T1WI is widely believed to be poor at 3 T. Recently, gray-white matter contrast on single-slice and multi-slice SE imaging with interslice gap was reported as better at 3 T than at 1.5 T. This Study examined the feasibility of interleaved SE T1WI of the brain at 3 T. This study also examined whether presaturation pulse (PP) sufficiently suppresses intra-arterial signals because these signals tend to be hyperintense due to longer T1 at 3 T. Materials and Methods. Subjects consisted of 18 healthy volunteers. Two sets of T1WI were performed using SE sequence. One set consisted of imaging without PP, and the other consisted of imaging with PP. Each set contained three types of gapless imaging as follows; sequential, 100% interleaved, and 200% interleaved imaging. In each subject, contrast-to-noise ratio between gray-matter and white-matter (CNRGM-WM) and intra-arterial signals were evaluated. Results. CNRGM-WM was significantly higher on interleaved images than on sequential images, regardless of PP (P < .0001). PP sufficiently suppressed intra-arterial signals (P < .0001). Conclusion. CNRGM-WM On SE T1WI at 3 T can be improved by interleaved acquisition, and PP sufficiently suppressed intra-arterial signals. Interleaved SE T1WI with PP appears clinically feasible at 3 T.
引用
收藏
页码:852 / 857
页数:6
相关论文
共 50 条
  • [1] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [2] Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI
    Alkan, Oezlem
    Kizilkilic, Osman
    Yildirim, Tuelin
    Alibek, Sedat
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2009, 15 (02): : 75 - 80
  • [3] Dynamic T1-weighted spin-echo MR imaging: The role of digital subtraction in the demonstration of enhancing brain lesions
    Melhem, ER
    Mehta, NR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (04): : 503 - 508
  • [4] Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Testa
    Stehling, C
    Niederstadt, T
    Krämer, S
    Kugel, H
    Schwindt, W
    Heindel, W
    Bachmann, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (04): : 536 - 542
  • [5] T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: A comparison in 20 patients with brain lesions
    Al-Saeed, O.
    Ismail, M.
    Athyal, R. P.
    Rudwan, M.
    Khafajee, S.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (04) : 366 - 372
  • [6] Comparison of Gadolinium-Enhanced Fat-Saturated T1-Weighted FLAIR and Fast Spin-Echo MRI of the Spine at 3 T for Evaluation of Extradural Lesions
    Shah, Komal B.
    Guha-Thakurta, Nandita
    Schellingerhout, Dawid
    Madewell, John E.
    Kumar, Ashok J.
    Costelloe, Colleen M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 697 - 703
  • [7] Gray matter-white matter contrast on spin-echo T1-weighted images at 3 T and 1.5 T: A quantitative comparison study
    Yasutaka Fushimi
    Yukio Miki
    Shin-ichi Urayama
    Tsutomu Okada
    Nobuyuki Mori
    Takashi Hanakawa
    Hidenao Fukuyama
    Kaori Togashi
    European Radiology, 2007, 17 (11) : 2921 - 2925
  • [8] Artifact reduction from metallic dental materials in T1-weighted spin-echo imaging at 3.0 tesla
    Zho, Sang-Young
    Kim, Min-Oh
    Lee, Keun-Woo
    Kim, Dong-Hyun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) : 471 - 478
  • [9] CLINICAL UTILITY OF PARTIAL FLIP ANGLE T2-WEIGHTED SPIN-ECHO IMAGING OF THE BRAIN
    CHANG, KH
    YI, JG
    HAN, MH
    CHO, MH
    HAN, MC
    CHO, ZH
    KIM, CW
    NEURORADIOLOGY, 1990, 32 (04) : 255 - 260
  • [10] Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence
    Shinji Naganawa
    Hiroko Satake
    Shingo Iwano
    Hisashi Kawai
    Seiji Kubota
    Tomohiro Komada
    Minako Kawamura
    Yasuo Sakurai
    Hiroshi Fukatsu
    European Radiology, 2008, 18