Label-free electrochemical immunoassay of carcinoembryonic antigen in human serum using magnetic nanorods as sensing probes

被引:22
作者
Fu, Xiaohong [1 ]
Wang, Jinyue [1 ]
Li, Na [1 ]
Wang, Li [1 ]
Pu, Lan [1 ]
机构
[1] Yibin Univ, Sch Chem & Chem Engn, Yibin 644000, Peoples R China
关键词
Magnetic nanorods; Carcinoembryonic antigen; Potentiometric immunosensor; Label-free; POTENTIOMETRIC IMMUNOSENSOR; NANOPARTICLES;
D O I
10.1007/s00604-009-0159-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new potentiometric immunoassay protocol for the determination of carcinoembryonic antigen (CEA) in human serum was designed by using a novel transparent immunoaffinity reactor. To construct such an affinity reactor, Fe3O4 nanorods with average diameter of 40 nm and length of 1.0 mu m were initially synthesized through hydrolysis of FeCl3 and FeSO4 in the urea solution, and then the synthesized nanorods were used as the immobilized affinity support for the conjugation of anti-CEA antibodies (bionanorods). With an external magnet, the magnetic bionanorods were attached to the surface of a self-made carbon paste electrode. The performance and factors influencing the immunosensors were evaluated. Under optimal conditions, the binding of CEA in the samples onto the immobilized anti-CEA changed the potential response, a dynamic range from 1.5 to 80 ng center dot mL(-1), and a detection limit of 0.9 ng center dot mL(-1) CEA (at 3 sigma). The immunosensors show good precision, high sensitivity, acceptable stability and reproducibility. The CEA concentrations of the clinical serum specimens assayed by the immunosensor show consistent results in comparison with those obtained by commercially available enzyme-linked immunosorbent assay.
引用
收藏
页码:437 / 442
页数:6
相关论文
共 20 条
[1]   Europium-Based Fluorescence Nanoparticle Sensor for Rapid and Ultrasensitive Detection of an Anthrax Biomarker [J].
Ai, Kelong ;
Zhang, Baohua ;
Lu, Lehui .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (02) :304-308
[2]   Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold [J].
Billah, Morsaline ;
Hays, Henry C. W. ;
Millner, Paul A. .
MICROCHIMICA ACTA, 2008, 160 (04) :447-454
[3]   Three-dimensional interdigitated electrode array as a transducer for label-free biosensors [J].
Bratov, Andrey ;
Ramon-Azcon, Javier ;
Abramova, Natalia ;
Merlos, Angel ;
Adrian, Javier ;
Sanchez-Baeza, Francisco ;
Marco, Maria-Pilar ;
Dominguez, Carlos .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :729-735
[4]   Determination of HIgG and anti-HIgG using a single potentiometric immunosensor and two different "competitive methods": Application to the analysis of globulin G in human serum [J].
Campanella, L. ;
Martini, E. ;
Tomassetti, M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :520-530
[5]   A novel mimetic peroxidase catalyst by using magnetite-containing silica nanoparticles as carriers [J].
Chen, Xiaolan ;
Zhao, Tingting ;
Zou, Jianli .
MICROCHIMICA ACTA, 2009, 164 (1-2) :93-99
[6]   Electrochemical analysis with nanoparticle-based biosystems [J].
de la Escosura-Muniz, Alfredo ;
Ambrosi, Adriano ;
Merkoci, Arben .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (07) :568-584
[7]   Study on highly sensitive potentiometric IgG immunosensor [J].
Feng, CL ;
Xu, YH ;
Song, LM .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) :190-192
[8]   Miniaturized module with biosensors for potentiometric determination of urea [J].
Grabowska, Ilona ;
Ksok, Ewa ;
Wyzkiewicz, Iwona ;
Chudy, Michal .
MICROCHIMICA ACTA, 2009, 164 (3-4) :299-305
[9]   A novel enzyme immunoassay based on potentiometric measurement of molecular adsorption events by an extended-gate field-effect transistor sensor [J].
Kamahori, Masao ;
Ishige, Yu ;
Shimoda, Maki .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :3080-3085
[10]   Integration of immunoassay into extended nanospace [J].
Kojima, Ryu ;
Mawatari, Kazuma ;
Renberg, Bjoern ;
Tsukahara, Takehiko ;
Kitamori, Takehiko .
MICROCHIMICA ACTA, 2009, 164 (3-4) :307-310