Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept

被引:62
|
作者
Sailer, Irena [1 ]
Asgeirsson, Asgeir G. [2 ]
Thoma, Daniel S. [2 ]
Fehmer, Vincent [1 ]
Aspelund, Thor [3 ]
Ozcan, Mutlu [2 ]
Pjetursson, Bjarni E. [1 ,4 ]
机构
[1] Univ Geneva, Div Fixed Prosthodont & Biomat, Univ Clin Dent Med, Geneva, Switzerland
[2] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent Med, Zurich, Switzerland
[3] Univ Iceland, Publ Hlth Sci, Reykjavik, Iceland
[4] Univ Iceland, Clin Reconstruct Dent, Fac Odontol, Reykjavik, Iceland
关键词
aging; bending moment; hybrid abutment; implant abutment; implant abutment connection; titanium resin base; zirconia abutment; CONTROLLED CLINICAL-TRIAL; ALL-CERAMIC RESTORATIONS; IN-VITRO; BENDING MOMENTS; SINGLE CROWNS; RESISTANCE; FAILURE; REGIONS; CANINE; COLOR;
D O I
10.1111/clr.13139
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThere is limited knowledge regarding the strength of zirconia abutments with internal and external implant abutment connections and zirconia abutments supported by a titanium resin base (Variobase, Straumann) for narrow diameter implants. ObjectivesTo compare the fracture strength of narrow diameter abutments with different types of implant abutment connections after chewing simulation. Material and methodsHundred and twenty identical customized abutments with different materials and implant abutment connections were fabricated for five groups: 1-piece zirconia abutment with internal connection (T1, Cares-abutment-Straumann BL-NC implant, Straumann Switzerland), 1-piece zirconia abutment with external hex connection (T2, Procera abutment-Branemark NP implant, Nobel Biocare, Sweden), 2-piece zirconia abutments with metallic insert for internal connection (T3, Procera abutment-Replace NP implant, Nobel Biocare), 2-piece zirconia abutment on titanium resin base (T4, LavaPlus abutment-VarioBase-Straumann BL-NC implant, 3M ESPE, Germany) and 1-piece titanium abutment with internal connection (C, Cares-abutment-Straumann BL-NC implant, Straumann, Switzerland). All implants had a narrow diameter ranging from 3.3 to 3.5mm. Sixty un-restored abutments and 60 abutments restored with glass-ceramic crowns were tested. Mean bending moments were compared using ANOVA with p-values adjusted for multiple comparisons using Tukey's procedure. ResultsThe mean bending moments were 52133Ncm (T4), 404 +/- 36Ncm (C), 311 +/- 106Ncm (T1) 265 +/- 22Ncm (T3) and 225 +/- 29 (T2) for un-restored abutments and 278 +/- 84Ncm (T4), 302 +/- 170Ncm (C), 190 +/- 55Ncm (T1) 80 +/- 102Ncm (T3) and 125 +/- 57 (T2) for restored abutments. For un-restored abutments, C and T4 had similar mean bending moments, significantly higher than those of the three other groups (p<.05). Titanium abutments (C) had significantly higher bending moments than identical zirconia abutments (T1) (p<.05). Zirconia abutments (T1) with internal connection had higher bending moments than zirconia abutments with external connection (T2) (p<.05). For all test groups, the bending moments were significantly reduced when restored with all-ceramic crowns. ConclusionsFor narrow diameter abutments, the fracture strength of 2-piece internal connected zirconia abutments fixed on titanium resin bases was similar to those obtained for 1-piece titanium abutments. Narrow diameter zirconia abutments with internal connection exhibited higher fracture strength than zirconia abutments with an external connection. Titanium abutments with an internal connection were significantly stronger than identical zirconia abutments.
引用
收藏
页码:411 / 423
页数:13
相关论文
共 40 条
  • [1] In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External Implant-Abutment Connections
    Sailer, Irena
    Sailer, Thomas
    Stawarczyk, Bogna
    Jung, Ronald Ernst
    Haemmerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 850 - 858
  • [2] Measurement of Fracture Strength of Zirconia Dental Implant Abutments with Internal and External Connections Using Acoustic Emission
    Soo, Suet Yeo
    Silikas, Nikolaos
    Satterthwaite, Julian
    MATERIALS, 2019, 12 (12)
  • [3] Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation
    Truninger, Thomas C.
    Stawarczyk, Bogna
    Leutert, Christian R.
    Sailer, Thomas R.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (01) : 12 - 18
  • [4] Bending Moments and Types of Failure of Zirconia and Titanium Abutments with Internal Implant-Abutment Connections: A Laboratory Study
    Leutert, Christian R.
    Stawarczyk, Bogna
    Truninger, Thomas C.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 505 - 512
  • [5] In Vitro Fatigue and Fracture Strength Testing of One-Piece Zirconia Implant Abutments and Zirconia Implant Abutments Connected to Titanium Cores
    Stimmelmayr, Michael
    Sagerer, Stefanie
    Erdelt, Kurt
    Beuer, Florian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 488 - 493
  • [6] Fracture Resistance of Internal Conical and External Hexagon: Regular and Narrow Implant-Abutment Assemblies
    Prado Naves Carneiro, Thiago de Almeida
    Dietrich, Lia
    Prudente, Marcel Santana
    da Silva Neto, Joao Paulo
    do Prado, Celio Jesus
    de Araujo, Cleudmar Amaral
    das Neves, Flavio Domingues
    IMPLANT DENTISTRY, 2016, 25 (04) : 510 - 514
  • [7] Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections
    Siadat, Hakimeh
    Beyabanaki, Elaheh
    Mousavi, Niloufar
    Alikhasi, Marzieh
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04): : 271 - 277
  • [8] Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments
    Atalay, Pelin
    Oztas, Dogan Derya
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (07) : 1060 - 1067
  • [9] Influence of Implant-Abutment Connection Biomechanics on Biological Response: A Literature Review on Interfaces between Implants and Abutments of Titanium and Zirconia
    Choi, Sunyoung
    Kang, Young Suk
    Yeo, In-Sung Luke
    PROSTHESIS, 2023, 5 (02): : 527 - 538
  • [10] Implants With Internal Hexagon and Conical Implant-Abutment Connections: An In Vitro Study of the Bacterial Contamination
    D'Ercole, Simonetta
    Scarano, Antonio
    Perrotti, Vittoria
    Mulatinho, Jorge
    Piattelli, Adriano
    Iezzi, Giovanna
    Tripodi, Domenico
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (01) : 31 - 36