Small fiber neuropathy diagnosis by a non-invasive electrochemical method: mimicking the in-vivo responses by optimization of electrolytic cell parameters

被引:7
作者
Calmet, Amandine [1 ,2 ,3 ,4 ,5 ]
Khalfallah, Kamel [6 ]
Ayoub, Hanna [6 ]
Lair, Virginie [1 ]
Griveau, Sophie [2 ,3 ,4 ,5 ]
Brunswick, Philippe [6 ]
Bedioui, Fethi [2 ,3 ,4 ,5 ]
Cassir, Michel [1 ]
机构
[1] Chim ParisTech, CNRS, Inst Rech Chim Paris, F-75005 Paris, France
[2] Chim ParisTech, Ecole Natl Super Chim Paris, Unite Technol Chim & Biol Sante, Paris, France
[3] CNRS, Unite Technol Chim & Biol Sante UMR 8258, Paris, France
[4] Univ Paris 05, Sorbonne Paris Cite, Unite Technol Chim & Biol Sante, Paris, France
[5] INSERM, Unite Technol Chim & Biol Sante 1022, Paris, France
[6] IMPETO Med, F-75014 Paris, France
关键词
Nickel electrode; electrochemical detection; chloride ions; neuropathy; viscosity; EXCESS PROPERTIES; VISCOSITY; NICKEL; CONDUCTIVITY; BREAKDOWN; CHLORIDE; DENSITY; SKIN; TOOL;
D O I
10.1016/j.electacta.2014.02.053
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Prevalence of type II diabetes and cardiometabolic diseases is increasing worldwide and early identification of their complications could reduce healthcare costs. An early complication of diabetes is small fiber neuropathy that can be diagnosed through assessment of sweat dysfunction. In this context, the Sudoscan (TM) technology developed by Impeto Medical provides early diagnosis, rapid and non-invasive analysis of sudomotor functions. This technology is based on measurements of skin current density via the imposition of low amplitude voltages (4 to 1.5V) between electrodes applied to the skin and measuring the low current generated. These electrodes are sensitive to the composition of the sweat produced by the eccrine glands when stimulated. To optimize the electrode materials and the diagnosis, a better insight into the origin of the electrochemical signals is needed by mimicking the in vivo results through the use of a model electrochemical cell reproducing physiological sweat conditions. In this paper, the electrode surface was modified with polymeric membranes to mimic the role of the filter of the skin and to get similar results to those obtained by Sudoscan (TM). Then, the composition of the electrolyte was changed by optimizing its viscosity to reduce the flow of Cl- ions to the electrode surface. The electrochemical behavior of the electrodes, measured in terms of current-voltage studied in artificial sweat, were compared to those of the Sudoscan (TM) technology. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 31 条
[1]   Breakdown of passive film on nickel in borate solutions containing halide anions [J].
Abd el Aal, EE .
CORROSION SCIENCE, 2003, 45 (04) :759-775
[2]  
Amer Diabet Assoc, 2013, DIABETES CARE, V36, pS11, DOI [10.2337/dc13-S011, 10.2337/dc12-1631]
[3]  
Atkins P.W., 2005, ELEMENTS PHYS CHEM, V4th
[4]   Electrochemical Kinetics of Anodic Ni Dissolution in Aqueous Media as a Function of Chloride Ion Concentration at pH Values Close to Physiological Conditions [J].
Ayoub, Hanna ;
Lair, Virginie ;
Griveau, Sophie ;
Brunswick, Philippe ;
Zagal, Jose H. ;
Bedioui, Fethi ;
Cassir, Michel .
ELECTROANALYSIS, 2012, 24 (02) :386-391
[5]   Ageing of nickel used as sensitive material for early detection of sudomotor dysfunction [J].
Ayoub, Hanna ;
Lair, Virginie ;
Griveau, Sophie ;
Galtayries, Anouk ;
Brunswick, Philippe ;
Bedioui, Fethi ;
Cassir, Michel .
APPLIED SURFACE SCIENCE, 2012, 258 (07) :2724-2731
[6]   Electrochemical Characterization of Nickel Electrodes in Phosphate and Carbonate Electrolytes in View of Assessing a Medical Diagnostic Device for the Detection of Early Diabetes [J].
Ayoub, Hanna ;
Griveau, Sophie ;
Lair, Virginie ;
Brunswick, Philippe ;
Cassir, Michel ;
Bedioui, Fethi .
ELECTROANALYSIS, 2010, 22 (21) :2483-2490
[7]  
Bockris J. O., 2002, MODERN ELECHROCHEMIS
[8]  
Brunswick P., 2007, France Patent, Patent No. 0753461
[9]  
Brunswick P., 2007, PCT, Patent No. [EP2008/052211, 2008052211]
[10]  
Casademont E., 2006, ELCTRODIALYSE TECHNI, pJ2840