Cricoid pressure: a simple, yet effective biofeedback trainer

被引:26
作者
Kopka, A [1 ]
Crawford, J [1 ]
机构
[1] N Glasgow Univ Hosp NHS Trust, Dept Anaesthesia, Western Infirm, Glasgow 611 6NT, Lanark, Scotland
关键词
education; medical; gastro-oesophageal reflux; laryngeal cartilages; cricoid cartilage;
D O I
10.1017/S0265021504006052
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Only regular training of anaesthetic personnel ensures safe and reliable application of cricoid pressure during rapid sequence induction of anaesthesia. Previously described training devices are either complicated, too expensive and usually unavailable, or they are very simple and do not correctly simulate the process of applying cricoid force. We designed and tested a cricoid pressure trainer with real-time display of applied force. The device is easy to assemble at relatively little cost with material widely available. It allows effective biofeedback training of the force required during the Sellick manoeuvre and can be used for routine staff assessment. Methods: Thirty-six anaesthesia assistants were assessed for their correct application of cricoid pressure. Previous training in, and knowledge of, applying cricoid pressure was first evaluated by a questionnaire. We designed a model for testing the application of cricoid force. Pre-training cricoid forces were obtained by asking the subjects to apply 'awake' (10 N = 1.020 kg) and 'asleep'(30 N = 3.060 kg) cricoid pressure on our model while blinded to the actual pressure produced. The volunteer was then trained to apply correct pressure employing real-time biofeedback. Post-training values were later determined with the subject again blinded to the actual applied pressure. Results: Post-training performance showed significant improvement in the application of the correct cricoid force (P < 0.0005). Only 8176 (3/36) of subjects applied incorrect 'awake' cricoid pressure after training vs. 5696, (20/36) before training. All participants applied correct 'asleep' cricoid pressure after training vs. 72,70 (26/36) failing before training. Conclusions: Our b1ofeedback cricold pressure trainer is effective in the assessment and training of correct cricoid pressure application by anaesthetic personnel.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 21 条
[1]   THE EFFECT OF CRICOID PRESSURE APPLICATION ON AIRWAY PATENCY [J].
ALLMAN, KG .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (03) :197-199
[2]   Use of a mechanical simulator for training in applying cricoid pressure [J].
Ashurst, N ;
Rout, CC ;
Rocke, BA ;
Gouws, E .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 77 (04) :468-472
[3]  
Benhamou D, 1995, Int J Obstet Anesth, V4, P30, DOI 10.1016/0959-289X(95)82226-Z
[4]   Cricoid pressure [J].
Brimacombe, JR ;
Berry, AM .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1997, 44 (04) :414-425
[5]   A novel method of measuring cricoid force [J].
Clayton, TJ ;
Vanner, RG .
ANAESTHESIA, 2002, 57 (04) :326-329
[6]   Cricoid pressure: which hand? [J].
Cook, TM ;
Godfrey, I ;
Rockett, M ;
Vanner, RG .
ANAESTHESIA, 2000, 55 (07) :648-653
[7]   The 50-millilitre syringe as an inexpensive training aid in the application of cricoid pressure [J].
Flucker, CJR ;
Hart, E ;
Weisz, M ;
Griffiths, R ;
Ruth, M .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2000, 17 (07) :443-447
[8]   Airway obstruction with cricoid pressure [J].
Hartsilver, EL ;
Vanner, RG .
ANAESTHESIA, 2000, 55 (03) :208-211
[9]   Fracture of the cricoid cartilage after Sellick's manoeuvre [J].
Heath, KJ ;
Palmer, M ;
Fletcher, SJ .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (06) :877-878
[10]   Cricoid pressure: Teaching the recommended level [J].
Herman, NL ;
Carter, B ;
VanDecar, TK .
ANESTHESIA AND ANALGESIA, 1996, 83 (04) :859-863