Scoring reading parameters: An inter-rater reliability study using the MNREAD chart

被引:15
作者
Baskaran, Karthikeyan [1 ]
Macedo, Antonio Filipe [1 ,2 ]
He, Yingchen [3 ]
Hernandez-Moreno, Laura [3 ]
Queiros, Tatiana [4 ]
Mansfield, J. Stephen [5 ]
Calabrese, Aurelie [6 ,7 ]
机构
[1] Linnaeus Univ, Dept Med & Optometry, Kalmar, Sweden
[2] Univ Minho Braga, Low Vis & Visual Rehabil Lab, Dept & Ctr Phys Optometry & Vis Sci, Braga, Portugal
[3] Univ Minnesota, Dept Ophthalmol & Visual Neurosci, Minneapolis, MN USA
[4] Hosp Braga, Serv Oftalmol, Braga, Portugal
[5] SUNY Coll Plattsburgh, Dept Psychol, Plattsburgh, NY 12901 USA
[6] Aix Marseille Univ, Marseille, France
[7] CNRS, Lab Psychol Cognit, Marseille, France
关键词
VISUAL FUNCTION; VISION; ACUITY; REPEATABILITY; VARIABILITY; PERFORMANCE; INDEX;
D O I
10.1371/journal.pone.0216775
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose First, to evaluate inter-rater reliability when human raters estimate the reading performance of visually impaired individuals using the MNREAD acuity chart. Second, to evaluate the agreement between computer-based scoring algorithms and compare them with human rating. Methods Reading performance was measured for 101 individuals with low vision, using the Portuguese version of the MNREAD test. Seven raters estimated the maximum reading speed (MRS) and critical print size (CPS) of each individual MNREAD curve. MRS and CPS were also calculated automatically for each curve using two different algorithms: the original standard deviation method (SDev) and a non-linear mixed effects (NLME) modeling. Intra-class correlation coefficients (ICC) were used to estimate absolute agreement between raters and/or algorithms. Results Absolute agreement between raters was 'excellent' for MRS (ICC = 0.97; 95% CI [0.96, 0.98]) and 'moderate' to 'good' for CPS (ICC = 0.77; 95% CI [0.69, 0.83]). For CPS, interrater reliability was poorer among less experienced raters (ICC = 0.70; 95% CI [0.57, 0.80]) when compared to experienced ones (ICC = 0.82; 95% CI [0.76, 0.88]). Absolute agreement between the two algorithms was 'excellent' for MRS (ICC = 0.96; 95% CI [0.91, 0.98]). For CPS, the best possible agreement was found for CPS defined as the print size sustaining 80% of MRS (ICC = 0.77; 95% CI [0.68, 0.84]). Absolute agreement between raters and automated methods was 'excellent' for MRS (ICC = 0.96; 95% CI [0.88, 0.98] for SDev; ICC = 0.97; 95% CI [0.95, 0.98] for NLME). For CPS, absolute agreement between raters and SDev ranged from 'poor' to 'good' (ICC = 0.66; 95% CI [0.3, 0.80]), while agreement between raters and NLME was 'good' (ICC = 0.83; 95% CI [0.76, 0.88]). Conclusion For MRS, inter-rater reliability is excellent, even considering the possibility of noisy and/or incomplete data collected in low-vision individuals. For CPS, inter-rater reliability is lower. This may be problematic, for instance in the context of multisite investigations or follow-up examinations. The NLME method showed better agreement with the raters than the SDev method for both reading parameters. Setting up consensual guidelines to deal with ambiguous curves may help improve reliability. While the exact definition of CPS should be chosen on a case-by-case basis depending on the clinician or researcher's motivations, evidence suggests that estimating CPS as the smallest print size sustaining about 80% of MRS would increase inter-rater reliability.
引用
收藏
页数:14
相关论文
共 31 条
[1]  
[Anonymous], R LANG ENV STAT COMP
[2]   Characterizing Functional Complaints in Patients Seeking Outpatient Low-Vision Services in the United States [J].
Brown, Jamie C. ;
Goldstein, Judith E. ;
Chan, Tiffany L. ;
Massof, Robert ;
Ramulu, Pradeep .
OPHTHALMOLOGY, 2014, 121 (08) :1655-+
[3]  
Calabrese A, 2017, MNREADR R PACKAGE AN
[4]   Comparing performance on the MNREAD iPad application with the MNREAD acuity chart [J].
Calabrese, Aurelie ;
To, Long ;
He, Yingchen ;
Berkholtz, Elizabeth ;
Rafian, Paymon ;
Legge, Gordon E. .
JOURNAL OF VISION, 2018, 18 (01)
[5]   Baseline MNREAD Measures for Normally Sighted Subjects From Childhood to Old Age [J].
Calabrese, Aurelie ;
Cheong, Allen M. Y. ;
Cheung, Sing-Hang ;
He, Yingchen ;
Kwon, MiYoung ;
Mansfield, J. Stephen ;
Subramanian, Ahalya ;
Yu, Deyue ;
Legge, Gordon E. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (08) :3836-3843
[6]   Development of a Reading Accessibility Index Using the MNREAD Acuity Chart [J].
Calabrese, Aurelie ;
Owsley, Cynthia ;
McGwin, Gerald ;
Legge, Gordon E. .
JAMA OPHTHALMOLOGY, 2016, 134 (04) :398-405
[7]  
Castro Celina Tamaki Monteiro de, 2005, Arq Bras Oftalmol, V68, P777
[8]   Nonlinear mixed-effects modeling of MNREAD data [J].
Cheung, Sing-Hang ;
Kallie, Christopher S. ;
Legge, Gordon E. ;
Cheong, Allen M. Y. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (02) :828-835
[9]  
Cudeck R, 2010, N D SER QUANT METHOD, P289
[10]   Fixation in patients with juvenile macular disease [J].
Filipe Macedo, Antonio ;
Nascimento, Sergio Miguel Cardoso ;
Silva Gomes, Augusto Oliveira ;
Teixeira Puga, Andre .
OPTOMETRY AND VISION SCIENCE, 2007, 84 (09) :852-858