A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II)

被引:124
作者
Han, Donghoon [2 ]
Kim, Yang-Rae [2 ]
Oh, Jeong-Wook [2 ]
Kim, Tae Hyun [3 ]
Mahajan, Rakesh Kumar [4 ]
Kim, Jong Seung [1 ]
Kim, Hasuck [2 ]
机构
[1] Korea Univ, Dept Chem, Seoul 136701, South Korea
[2] Seoul Natl Univ, Dept Chem, Seoul 151747, South Korea
[3] Seoul Natl Univ, Dept Phys & Astron, Seoul 151742, South Korea
[4] Guru Nanak Dev Univ, Dept Chem, Amritsar 143005, Punjab, India
基金
新加坡国家研究基金会;
关键词
ANODIC-STRIPPING VOLTAMMETRY; SELF-ASSEMBLED MONOLAYERS; ELECTRON-TRANSFER; FERROCENE DERIVATIVES; AQUEOUS-SOLUTION; DNA MONOLAYERS; SOIL SAMPLES; HG-II; GOLD; ENZYME;
D O I
10.1039/b908457f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a selective, sensitive, and re-usable electrochemical sensor for Hg2+ ion detection. This sensor is based on the Hg2+-induced conformational change of a single-stranded DNA (ssDNA) which involves an electroactive, ferrocene-labeled DNA hairpin structure and provides strategically the selective binding of a thymine-thymine mismatch for the Hg2+ ion. The ferrocene-labeled DNA is self-assembled through S-Au bonding on a polycrystalline gold electrode surface and the surface blocked with 3-mercapto-1-propanol to form a mixed monolayer. The modified electrode showed a voltammetric signal due to a one-step redox reaction of the surface-confined ferrocenyl moiety. The `signal-on' upon mercury binding could be attributed to a change in the conformation of ferrocene-labeled DNA from an open structure to a restricted hairpin structure. The differential pulse voltammetry (DPV) of the modified electrode showed a linear response of the ferrocene oxidation signal with increase of Hg2+ concentration in the range between 0.1 and 2 mu M with a detection limit of 0.1 mM. The molecular beacon mercury(II) ion sensor was amenable to regeneration by simply unfolding the ferrocene-labeled DNA in 10 mu Mcysteine, and could be regenerated with no loss in signal gain upon subsequent mercury(II) ion binding.
引用
收藏
页码:1857 / 1862
页数:6
相关论文
共 63 条
[1]   Calix[4]arene-based, Hg2+-induced intramolecular fluorescence resonance energy transfer chemosensor [J].
Ben Othman, Amel ;
Lee, Jeong Won ;
Wu, Jia-Sheng ;
Kim, Jong Seung ;
Abidi, Rym ;
Thuery, Pierre ;
Strub, Jean Marc ;
Van Dorsselaer, Alain ;
Vicens, Jacques .
JOURNAL OF ORGANIC CHEMISTRY, 2007, 72 (20) :7634-7640
[2]   Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2000, 424 (01) :65-76
[3]   Modification of ferrocene-containing redox gel sensor performance by copolymerization of charged monomers [J].
Bu, HZ ;
English, AM ;
Mikkelsen, SR .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3951-3957
[4]   NAD(P)H sensors based on enzyme entrapment in ferrocene-containing polyacrylamide-based redox gels [J].
Bu, HZ ;
Mikkelsen, SR ;
English, AM .
ANALYTICAL CHEMISTRY, 1998, 70 (20) :4320-4325
[5]   Application of new sol-gel electrochemical sensors to the determination of trace mercury [J].
Cabello-Carramolino, G. ;
Petit-Dominguez, M. D. .
ANALYTICA CHIMICA ACTA, 2008, 614 (01) :103-111
[6]   Reversible colorimetric probes for mercury sensing [J].
Coronado, E ;
Galán-Mascaros, JR ;
Martí-Gastaldo, C ;
Palomares, E ;
Durrant, JR ;
Vilar, R ;
Gratzel, M ;
Nazeeruddin, MK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (35) :12351-12356
[7]   Health risks of gold miners: A synoptic review [J].
Eisler, R .
ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2003, 25 (03) :325-345
[8]   Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA [J].
Fan, CH ;
Plaxco, KW ;
Heeger, AJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (16) :9134-9137
[9]   Determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry [J].
Fong, Bonnie Mei Wah ;
Siu, Tak Shing ;
Lee, Joseph Sai Kit ;
Tam, Sidney .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (05) :281-287
[10]   Synthesis, characterization, and evaluation of ferrocene-theophylline conjugates for use in electrochemical enzyme immunoassay [J].
Forrow, NJ ;
Foulds, NC ;
Frew, JE ;
Law, JT .
BIOCONJUGATE CHEMISTRY, 2004, 15 (01) :137-144