Yield measurement and Monte Carlo correction of CPDG neutron generator

被引:3
|
作者
Zhang, Yingzeng [1 ]
Zeng, Jun [1 ]
Guo, Xiaofeng [1 ,2 ]
Zheng, Pu [1 ]
Li, Gang [3 ]
Xiang, Yongchun [1 ]
Hao, Fanhua [1 ]
Xiang, Qingpei [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Peoples R China
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Northeast Normal Univ, Sch Phys, Changchun 130024, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
Neutron generator; Neutron yield; Monte Carlo simulation; Neutron distribution; ACTIVATION-ANALYSIS;
D O I
10.1016/j.nimb.2018.05.021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
It is useful to obtain the exact neutron yield and distribution of a portable neutron generator. In this paper, the neutron yield of a K400 accelerator D-D neutron source under conditions of 160 kV and 25 uA is 1.69 x 10(6) +/- 4.1 x 10(4) n/s, which is calibrated using the associated proton method. A long counter consisting of a 3 He counter surrounded by a paraffin cylinder was used as secondary standard after efficiency calibration using a K400 accelerator. The Monte Carlo method is then used to evaluate the distribution change of emitted neutrons from each surface of the CPDG caused by its structural materials. Energy spectrum distortion and angle distribution distortion of emitted neutrons are studied. Simulation results show that the proportion of the forward neutron is reduced and the proportion of the lateral neutron is increased. The number of neutron transporting into the counter has been reduced by 28.1%, 28.4%, 29.8%, 29.0%, 28.7%, and 28.0% for acceleration voltages of 90 kV, 100 kV, 110 kV, 120 kV, 130 kV, and 160 kV, respectively. In addition, the respective yield correction factors caused by structural materials are 1.36, 1.38, 1.38, 1.34, 1.37, and 1.39. The neutron yield of the CPDG is 1.28 x 10(6) and 1.75 x 10(6) before and after Monte Carlo correction when working at conditions of 130 kV and 600 mu A. The total uncertainty of this result is approximately 6%.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [1] Simulation of the cement measurement based on the pulse DT neutron generator: A Monte Carlo study
    Gao, Yadong
    Li, Jiaming
    Li, Jichen
    Liu, Linmao
    PLOS ONE, 2021, 16 (06):
  • [2] Metallic materials analysis by DT neutron generator-based inelastic neutron scattering system: Measurement and Monte Carlo simulation
    Cheng, Can
    Hei, Daqian
    Jia, Wenbao
    Shan, Qing
    Ling, Yongsheng
    Shi, Chao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 515 : 31 - 36
  • [3] Monte Carlo simulation of neutron sensitivity of microfission chamber in neutron flux measurement
    Wu, Ze-Peng
    Jiang, Xin-Biao
    Zhang, Wen-Shou
    Su, Chun-Lei
    Zhang-Sun, Yong-Gang
    Bao, Li-Hong
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (06)
  • [4] Monte Carlo simulation of neutron sensitivity of microfission chamber in neutron flux measurement
    Ze-Peng Wu
    Xin-Biao Jiang
    Wen-Shou Zhang
    Chun-Lei Su
    Yong-Gang Zhang-Sun
    Li-Hong Bao
    Nuclear Science and Techniques, 2022, 33
  • [5] Improved shielding design with an accelerated Monte Carlo simulation for a neutron generator at Missouri S&T
    Sahiner, Huseyin
    Norris, Edward T.
    Bugis, Abdulaleem A.
    Liu, Xin
    PROGRESS IN NUCLEAR ENERGY, 2017, 97 : 123 - 132
  • [6] Verification of neutron radioscopic measurement of void fraction by Monte Carlo simulation
    Unesaki, H
    Hibiki, T
    Mishima, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 405 (01) : 98 - 104
  • [7] Monte Carlo modeling of a 14 MeV neutron generator being used as a teaching tool
    Joneja, OP
    Fruh, R
    Chawla, R
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 469 - 472
  • [8] Monte Carlo simulations of a D-T neutron generator shielding for landmine detection
    Reda, A. M.
    RADIATION MEASUREMENTS, 2011, 46 (10) : 1187 - 1193
  • [9] Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator
    Roman J. Shypailo
    K. J. Ellis
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 247 - 253
  • [10] Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator
    Shypailo, Roman J.
    Ellis, K. J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (01) : 247 - 253