Unsteady Character and Flow Fields in an Axial Blood Pump under Pulsatile Pressure Boundary Condition

被引:3
作者
Wang, Mengyu [1 ]
Xu, Han [1 ]
Jin, Donghai [1 ,2 ]
Gui, Xingmin [1 ,2 ]
机构
[1] Beihang Univ, Aeroengine Numer Simulat Res Ctr, Beijing, Peoples R China
[2] Collaborat Innovat Ctr Adv Aeroengine, Beijing, Peoples R China
来源
2018 2ND INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES IN DESIGN, MECHANICAL AND AERONAUTICAL ENGINEERING (ATDMAE 2018) | 2018年 / 408卷
关键词
HUMAN CIRCULATORY-SYSTEM; DAMAGE; MODEL;
D O I
10.1088/1757-899X/408/1/012014
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Blood pumps have been widely used as a temporary method for heart failure. In recent years, the challenging factors in design have generally concentrated on how to deal with the complicated time-dependent fluid dynamics. Therefore, this research studies the impact to flow field by pulsatile boundary condition with both steady and unsteady numerical simulations. For steady computation, total pressures of 20, 40, 60, 80, 100mmHg and an average pressure of 120mmHg were given at the inlet and outlet respectively, and an unsteady simulation was then conducted with the same fixed pressure of 120mmHg at the outlet but a periodical sinusoidal pressure within 20 and 100mmHg at the inlet. Compared with a single character line drawn through the steady points, the unsteady computation resulted in a closed elliptic character curve. In the whole range of operation of the unsteady condition, flow field showed a well-attached flow in rotor passage but a large area of recirculation in the second row of stator passages. By contrast, flow field in the first row of stator passages and the pressure on the surface of rotor blades were greatly impacted by the acceleration and deceleration of the flow rate, which can be well explained by the change of incidence. Besides, flow rate acceleration or deceleration exaggerated a non-uniform distribution of velocity, which can easily form a larger area of high scalar shear stress than the steady results. A special pressure distribution between rotors and stators was also observed in unsteady flow.
引用
收藏
页数:8
相关论文
共 50 条
[21]   Research on Energy Transport Characteristics of an Axial Flow Circulating Pump under Unpowered Driven and Pump Operating Conditions [J].
Lv, Hao ;
Chen, Yujin ;
Wang, Jiaqing ;
Sheng, Xiangzhuo ;
Wei, Xianghui ;
Chen, Songying .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (08) :10805-10818
[22]   Numerical And Experimental Investigation of Aerodynamics On Flow Around A Highly Loaded Low-Pressure Turbine Blade with Flow Separation Under Steady And Periodic Unsteady Inlet Flow Condition [J].
Nikparto, Ali ;
Schobeiri, Meinhard T. .
PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2016, VOL 5A, 2016,
[23]   Effect of periodic body acceleration and pulsatile pressure gradient pressure on non-Newtonian blood flow in arteries [J].
Mosayebidorcheh, S. ;
Hatami, M. ;
Mosayebidorcheh, T. ;
Ganji, D. D. .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (03) :703-708
[24]   Unified Theory of Unsteady Planar Laminar Flow in the Presence of Arbitrary Pressure Gradients and Boundary Movement [J].
Daidzic, Nihad E. .
SYMMETRY-BASEL, 2022, 14 (04)
[25]   Experimental and CFD Investigation on Flow Behaviors of a NPP Pump under Natural Circulation Condition [J].
Li, Weitong ;
Yu, Lei ;
Hao, Jianli ;
Li, Mingrui .
SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2019, 2019
[26]   Outflow boundary conditions for 3D simulations of non-periodic blood flow and pressure fields in deformable arteries [J].
Vignon-Clementel, I. E. ;
Figueroa, C. A. ;
Jansen, K. E. ;
Taylor, C. A. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (05) :625-640
[27]   Combined resonance of pulsatile flow-transporting FG nanotubes under forced excitation with movable boundary [J].
Jin, Qiduo ;
Ren, Yiru ;
Yuan, Fuh-Gwo .
NONLINEAR DYNAMICS, 2023, 111 (07) :6157-6178
[28]   Experimental and numerical investigation on the effect of tip leakage vortex induced cavitating flow on pressure fluctuation in an axial flow pump [J].
Shen Xi ;
Zhang Desheng ;
Xu Bin ;
Shi Weidong ;
van Esch, B. P. M. .
RENEWABLE ENERGY, 2021, 163 :1195-1209
[29]   Unsteady pulsatile fractional Maxwell viscoelastic blood flow with Cattaneo heat flux through a vertical stenosed artery with body acceleration [J].
El Kot, M. A. ;
Abd Elmaboud, Y. .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (06) :4355-4368
[30]   Effect of Conical Spiral Flow Channel and Impeller Parameters on Flow Field and Hemolysis Performance of an Axial Magnetic Blood Pump [J].
Yang, Wei-Bo ;
Zhou, Jian ;
Xiao, Wei-Hu ;
Peng, Si-Jie ;
Hu, Ye-Fa ;
Li, Ming ;
Wu, Hua-Chun .
PROCESSES, 2022, 10 (05)