Effect of confining pressure distribution on the dilation behavior in FRP-confined plain concrete columns using stone, brick and recycled aggregates

被引:29
作者
Choudhury, M. S. I. [1 ]
Amin, A. F. M. S. [1 ]
Islam, M. M. [1 ]
Hasnat, A. [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Civil Engn, Dhaka 1000, Bangladesh
关键词
Fiber-reinforced polymer; Confinement; Brick aggregate concrete; Recycled stone aggregate concrete; Recycled brick aggregate concrete; Digital image correlation technique (DICT); Dilation; Stress-strain response; Fracture behavior; Confined concrete model parameters; STRESS-STRAIN MODEL; AXIAL COMPRESSIVE BEHAVIOR; HIGH-STRENGTH CONCRETE; TRIAXIAL COMPRESSION; RECTANGULAR COLUMNS; COMPOSITES;
D O I
10.1016/j.conbuildmat.2015.11.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In a confined column, the dilation phenomenon and the geometry of the column cross-section govern the magnitude of the confining pressure and confining pressure distribution, respectively. High-definition video shows rapid post-peak failure events to occur in columns experiencing either large dilation or large confining pressure displaying a characteristically different composite action in such concretes under confinement. To investigate the origin of such a behavior, transformations in the intrinsic stiffness parameters of the fundamental stress-strain responses are critically compared between concretes having significant and insignificant dilation properties. A test database with 40 circular columns confined with fiber-reinforced polymer (FRP) subjected to uniform confining pressure distributions along with 20 unconfined (control) specimens was objectively compared with an existing symmetric test database of square columns subjected to nonuniform confining pressure distributions. Stress-strain responses of confined concrete columns with larger dilation properties revealed a significantly increased initial stiffness and markedly decreased final stiffness due to early mobilization in the FRP confinement compared to columns of stone aggregate concrete with insignificant dilation properties. The uniformity of the confining pressure distribution of circular columns has been credited with more effectively restraining the dilation-induced phenomena compared to square confined columns. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:541 / 551
页数:11
相关论文
共 35 条
[1]  
Abdelrahman K, 2014, CONCRETE SOLUTIONS: PROCEEDINGS OF CONCRETE SOLUTIONS, 5TH INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, P253
[2]  
ACI (American Concrete Institute), 2008, ACI440
[3]   Assessing the ITZ microcracking via scanning electron microscope and its effect on the failure behavior of concrete [J].
Akçaoglu, R ;
Tokyay, M ;
Çelik, T .
CEMENT AND CONCRETE RESEARCH, 2005, 35 (02) :358-363
[4]  
Akhtaruzzaman A.A., 1983, ACI Concrete International: Design and Construction, V5, P58
[5]  
Amin A.F.M.S., 2015, J MAT CIV ENG
[6]  
[Anonymous], 1968, ACI J P
[7]  
[Anonymous], 2011, THESIS
[8]   State of the art report - Part 2: Mechanical micro-cracking of concrete [J].
Bascoul, A .
MATERIALS AND STRUCTURES, 1996, 29 (186) :67-78
[9]  
CARRASQUILLO RL, 1981, ACI J, V78, P179
[10]  
Choudhury M, 2012, THESIS