Variance-based iterative image reconstruction from few views in limited-angle C-arm computed tomography

被引:0
作者
El Hakimi, Wissam [1 ]
Sakas, Georgios [1 ]
机构
[1] Tech Univ Darmstadt, Interact Graph Syst Grp GRIS, D-64283 Darmstadt, Germany
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
关键词
C-arm; CBCT; iterative reconstruction; variance; CONE-BEAM CT;
D O I
10.1117/12.2043625
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
C-arm cone-beam computed tomography offers CT-like 3D imaging capabilities, but with the additional advantage of being appropriate for interventional suites. Due to the limitations of the data acquisition system, projections are oft acquired in a short scan angular range, resulting in significant artifacts, if conventional analytic formulas are applied. Furthermore, the presence of high-density objects, like metal parts, induces streak-like artifacts, which can obscure relevant anatomy. We present a new algorithm to reduce such artifacts and enhance the quality of reconstructed 3D volume. We make use of the variance of estimated voxel values over all projections to decrease the ground artifact level. The proposed algorithm is less sensitive to data truncation, and does not require explicit estimation of missing data. The number of required images is very low (up to 56 projections), which have several benefits, like significant reduction of patient dose and shortening of the acquisition time. The performance of the proposed method is demonstrated based on simulations and phantom data.
引用
收藏
页数:7
相关论文
共 14 条
  • [1] Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    Bal, Matthieu
    Spies, Lothar
    [J]. MEDICAL PHYSICS, 2006, 33 (08) : 2852 - 2859
  • [2] The digital TV filter and nonlinear denoising
    Chan, TF
    Osher, S
    Shen, JH
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) : 231 - 241
  • [3] Joseph P., MED PHYS, V7, P692
  • [4] C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology
    Orth, Robert C.
    Wallace, Michael J.
    Kuo, Michael D.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : 814 - 820
  • [5] Parker D, MED PHYS, V9, P254
  • [6] Improved total variation-based CT image reconstruction applied to clinical data
    Ritschl, Ludwig
    Bergner, Frank
    Fleischmann, Christof
    Kachelriess, Marc
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) : 1545 - 1561
  • [7] Artefacts in CBCT: a review
    Schulze, R.
    Heil, U.
    Gross, D.
    Bruellmann, D. D.
    Dranischnikow, E.
    Schwanecke, U.
    Schoemer, E.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 265 - 273
  • [8] Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
    Sidky, Emil Y.
    Pan, Xiaochuan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) : 4777 - 4807
  • [9] Smith B, 1985, MED IMAGING IEEE T, V4, P14
  • [10] Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT
    Veldkamp, Wouter J. H.
    Joemai, Raoul M. S.
    van der Molen, Aart J.
    Geleijns, Jacob
    [J]. MEDICAL PHYSICS, 2010, 37 (02) : 620 - 628