High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:0
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
来源
关键词
Paroxetine; MWCNTs; Nafion; Voltammetry; SEROTONIN REUPTAKE INHIBITORS; PHARMACEUTICAL FORMULATIONS; METABOLITES; CHROMATOGRAPHY; SERTRALINE;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A glassy carbon electrode modified with a Nafion-MWCNT composite is shown to enable the high sensitive determination of paroxetine using differential pulse voltammetry in phosphate buffer of pH 6.5. At a preconcentration time of 15 s, the calibration graph is linear in the 0.1 mu M (0.033 mg.L-1) to 2.5 mu M (0.82 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 60 s is as low as 2.6 mu g.L-1. The repeatability of the method at a 0. 16 mg.L-1 concentration level, expressed as the RSD, is 4.1% (for n = 5). The method was successfully applied and validated by analyzing paroxetine in drug and urine samples.
引用
收藏
页码:7528 / 7539
页数:12
相关论文
共 50 条
  • [41] Selective and Highly Sensitive Voltammetric Determination of Citalopram with Glassy Carbon Electrode
    Madej, Maria
    Kochana, Jolanta
    Bas, Boguslaw
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (08) : H359 - H369
  • [42] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Suling Yang
    Ran Yang
    Gang Li
    Jianjun Li
    Lingbo Qu
    Journal of Chemical Sciences, 2010, 122 : 919 - 926
  • [43] VOLTAMMETRIC DETERMINATION OF METHYLPARABAN IN COSMETICS USING A MULTI-WALL CARBON NANOTUBES/NAFION COMPOSITE MODIFIED GLASSY CARBON ELECTRODE
    Luo, Peili
    Liu, Jie
    Li, Yamin
    Miao, Yurui
    Ye, Baoxian
    ANALYTICAL LETTERS, 2012, 45 (16) : 2445 - 2454
  • [44] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Yang, Suling
    Yang, Ran
    Li, Gang
    Li, Jianjun
    Qu, Lingbo
    JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (06) : 919 - 926
  • [45] Electrochemical Determination of Phenylethanolamine A Based on Nafion/MWCNTs/AuNPs Modified Carbon Electrode
    Lai, Yanjun
    Bai, Jing
    Zhu, Wei
    Xian, Yuezhong
    Jin, Litong
    CHINESE JOURNAL OF CHEMISTRY, 2013, 31 (02) : 221 - 229
  • [46] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    Baranowska, I.
    Bijak, K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (10) : 891 - 895
  • [48] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895
  • [49] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [50] Voltammetric Determination of Tenoxicam in Drug Formulation at Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Cabuk, Ahmet
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (05): : 4508 - 4519