Voltage Distribution Analysis of High Coupled Split Reactor in 500 kV AC Fault Current Limiter

被引:5
作者
Wu, Kaijian [1 ,2 ]
Yuan, Zhao [1 ,2 ]
Ye, Jingjing [1 ,2 ]
Liu, Junxiang [3 ]
Mo, Wenxiong [3 ]
Wang, Yong [3 ]
Chen, Lixue [1 ,2 ]
He, Junlei [1 ,2 ]
Pan, Yuan [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Key Lab Pulsed Power Technol, Minist Educ, Wuhan 430074, Peoples R China
[3] Guangzhou Power Supply Bur Co Ltd, Test & Res Inst, Guangzhou 514010, Peoples R China
关键词
Encapsulation; Integrated circuit modeling; Insulation; Couplings; Inductance; Power grids; Inductors; Fault current limiter; high coupled split reactor; insulation; lightning impulse; switching impulse; FAST TRANSIENT OVERVOLTAGE; TRANSFORMER; FREQUENCY; CIRCUIT;
D O I
10.1109/ACCESS.2020.3029796
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the increase of short circuit current, measures should be taken to reduce the impact. Among various measures, a new technique to interrupt or limit current is proposed and applied to power grid based on high coupled split reactor (HCSR). As the key equipment in new technique, the insulation design of HCSR is a priority. Previous works mainly involve voltage across HCSR in different working states, and take the whole voltages as design requirements. It is rough and takes no account of voltage distribution inside HCSR, thus not suitable for insulation design of HCSR. In order to analyze the overvoltage problems and determine insulation demands for HCSR, this article establishes the equivalent circuit model in turn unit to calculate the voltage distribution inside HCSR, which is simplified and accurate enough for HCSR. A 500 kV AC fault current limiter is briefly introduced, and voltages between turns or arms in HCSR are obtained. The voltage between turns are evenly distributed and voltage between arms are very low under switching impulse. As for lightning impulse, maximum turn-to-turn voltages mainly appear in the end of encapsulations, and the voltage between arms in current sharing state is considerable. This article gives the calculation method and general rules of voltage distribution inside HCSR, and it has great significance for the insulation design of HCSR.
引用
收藏
页码:185804 / 185815
页数:12
相关论文
共 44 条
[41]   Trial design of a 6.6-kV magnetic shielding type of superconducting fault current limiter and performance analysis based on a finite element method [J].
Kado, H ;
Ichikawa, M ;
Ueda, H ;
Ishiyama, A .
ELECTRICAL ENGINEERING IN JAPAN, 2003, 145 (02) :50-57
[42]   A Study of Logistic Regression-Based Discrimination Method of False Overcurrent Alarm of 500kV High-voltage Shunt Reactor [J].
Gao, Jian ;
Feng, Shilin ;
Huang, Qi ;
Zhang, Zhenyuan ;
Luo, Rongsen ;
Teng, Yufei .
2018 INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE), 2018, :218-222
[43]   Simulation and experimental analysis of three-dimensional temperature distribution of ±400-kV converter transformer valve-side resin impregnated paper bushing under high current [J].
Xie, Gengsheng ;
Shi, Shifeng ;
Wang, Qingyu ;
Liu, Peng ;
Peng, Zongren .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (15) :2989-3003
[44]   Analysis on fault current limiting and bus-voltage sag suppressing operations of SFCLs using magnetic coupling of two coils according to their application locations in a power distribution system [J].
Kim, J. S. ;
Lim, S. H. ;
Kim, J. C. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2011, 471 (21-22) :1358-1363