Voltage Distribution Analysis of High Coupled Split Reactor in 500 kV AC Fault Current Limiter

被引:5
作者
Wu, Kaijian [1 ,2 ]
Yuan, Zhao [1 ,2 ]
Ye, Jingjing [1 ,2 ]
Liu, Junxiang [3 ]
Mo, Wenxiong [3 ]
Wang, Yong [3 ]
Chen, Lixue [1 ,2 ]
He, Junlei [1 ,2 ]
Pan, Yuan [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Key Lab Pulsed Power Technol, Minist Educ, Wuhan 430074, Peoples R China
[3] Guangzhou Power Supply Bur Co Ltd, Test & Res Inst, Guangzhou 514010, Peoples R China
关键词
Encapsulation; Integrated circuit modeling; Insulation; Couplings; Inductance; Power grids; Inductors; Fault current limiter; high coupled split reactor; insulation; lightning impulse; switching impulse; FAST TRANSIENT OVERVOLTAGE; TRANSFORMER; FREQUENCY; CIRCUIT;
D O I
10.1109/ACCESS.2020.3029796
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the increase of short circuit current, measures should be taken to reduce the impact. Among various measures, a new technique to interrupt or limit current is proposed and applied to power grid based on high coupled split reactor (HCSR). As the key equipment in new technique, the insulation design of HCSR is a priority. Previous works mainly involve voltage across HCSR in different working states, and take the whole voltages as design requirements. It is rough and takes no account of voltage distribution inside HCSR, thus not suitable for insulation design of HCSR. In order to analyze the overvoltage problems and determine insulation demands for HCSR, this article establishes the equivalent circuit model in turn unit to calculate the voltage distribution inside HCSR, which is simplified and accurate enough for HCSR. A 500 kV AC fault current limiter is briefly introduced, and voltages between turns or arms in HCSR are obtained. The voltage between turns are evenly distributed and voltage between arms are very low under switching impulse. As for lightning impulse, maximum turn-to-turn voltages mainly appear in the end of encapsulations, and the voltage between arms in current sharing state is considerable. This article gives the calculation method and general rules of voltage distribution inside HCSR, and it has great significance for the insulation design of HCSR.
引用
收藏
页码:185804 / 185815
页数:12
相关论文
共 44 条
  • [21] A Novel Fast Energy Storage Fault Current Limiter Topology for High-Voltage Direct Current Transmission System
    Chen, Hechong
    Yuan, Jiaxin
    Zhou, Hang
    Xu, Shunkai
    Zou, Chunhang
    Chen, Fan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (05) : 5032 - 5046
  • [22] Fault analysis and simulation of ground-fault accident on transformer in 500 kV AC/DC grids
    Zhang, Bo
    Lu, Ping
    Kong, Jinjiao
    Liu, Rui
    Cao, Quanliang
    Shao, Hongbo
    Deng, Wanting
    Chen, Jun
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 60 (01) : 1 - 12
  • [23] 66 kV/1 kA High-Tc superconducting fault current limiter magnet
    Yazawa, T
    Ootani, Y
    Sakai, M
    Kuriyama, T
    Urata, M
    Tokunaga, Y
    Inoue, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 2059 - 2062
  • [24] Cryostat for 66 kV/750 a high-Tc superconducting fault current limiter magnet
    Ohtani, Y
    Yazawa, T
    Kurita, S
    Kuriyama, T
    Nomura, S
    Ohkuma, T
    Hobara, N
    Takahashi, Y
    Inoue, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 855 - 858
  • [25] Design and test results of 4.6 kV high-Tc superconducting fault current limiter
    Yazawa, T
    Yoneda, E
    Matsuzaki, J
    Shimada, M
    Kuriyama, T
    Nomura, S
    Ohkuma, T
    Sato, Y
    Takahashi, Y
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2511 - 2514
  • [26] Development of 66 kV/750 A High-Tc superconducting fault current limiter magnet
    Yazawa, T
    Ootani, Y
    Sakai, M
    Kuriyama, T
    Nomura, S
    Ohkuma, T
    Hobara, N
    Takahashi, Y
    Inoue, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 786 - 790
  • [27] Current dividing process of paralleled circuit breakers with high coupled split reactor
    Yuan, Z. (yuanzhao8507@163.com), 2008, Science Press (38): : 2008 - 2014
  • [28] Fast AC reactor-based fault current limiters application in distribution network
    Radmanesh, Hamid
    Fathi, Seyed Hamid
    HIGH VOLTAGE, 2018, 3 (03): : 232 - 243
  • [29] Design and test results of 66 kV high-Tc superconducting fault current limiter magnet
    Yazawa, T.
    Ootani, Y.
    Sakai, M.
    Otsuki, M.
    Kuriyarna, T.
    Urata, M.
    Tokunaga, Y.
    Inoue, K.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 683 - 686
  • [30] Numerical Analysis of the Current and Voltage Sharing Issues for Resistive Fault Current Limiter Using YBCO Coated Conductors
    Hong, Z.
    Jin, Z.
    Ainslie, M.
    Sheng, J.
    Yuan, W.
    Coombs, T. A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1198 - 1201